Deutz · CAN communication and shutdown
Deutz CAN messages: torque and speed requests, wastegate, EGR and throttle actuators fault codes
Control messages the EMR4 exchanges over CAN: torque and speed requests from the machine controller (SPN 520, 898, 523605 and related), and the messages with the smart actuators for the wastegate, EGR valve, intake throttle and exhaust flaps. Each code names the message and whether it timed out or arrived wrong.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 520 FMI 9 to SPN 524125 FMI 9 are all about the cAN messages: torque and speed requests, wastegate, EGR and throttle actuators. Most are lost message faults; none needs an immediate stop. Start with this check: read the status of the machine controller or actuator first, since it is the sender.
How urgent are they?
None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.
- Check soon24
What should I check first?
Read the status of the machine controller or actuator first, since it is the sender
Shared checks24 of 24
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Machine - CAN torque rotation speed control11 codes
Deutz SPN 520 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
The EMR4 reports a timeout of the CAN torque and speed control message from the machine. The expected message did not arrive in its time window. Deutz list: KWP code 306, blink code 119. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
- Message ID mismatch after software change
Checks
- 1Check the machine controller is powered and running, since a dead controller sends nothing
- 2Measure CAN-H to CAN-L resistance at the diagnostic plug and check the terminators
- 3Use SerDia to see whether the speed and torque request arrives at all
- 4Check the CAN wires for chafing and loose connectors
- 5Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523605 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 300, blink code 118.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523606 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 301, blink code 119.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523766 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 281, blink code 118.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523767 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 282, blink code 118.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523768 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 283, blink code 119.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523769 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 284, blink code 119.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523776 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 291, blink code 119.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523777 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 292, blink code 119.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523778 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 293, blink code 118.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523779 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout
Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message. The torque and speed control message is the request in which the machine controller tells the engine how much torque or speed to deliver for the hydraulics or drive. Deutz list: KWP code 294, blink code 118.· Lost messageLost messageCheck soonCauses
- Machine controller not sending the message
- CAN wiring fault
Checks
- 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
- 2Check the machine controller is powered and running, since a dead controller sends nothing
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Machine - Externally requested engine rotation speed1 code
Deutz SPN 898 FMI 9Machine - Externally requested engine rotation speed: Abnormal update rate timeout
The EMR4 reports a timeout of the externally requested engine speed message. The CAN speed request from the machine is no longer arriving. Deutz list: KWP code 305, blink code 118. The externally requested speed is the target a machine controller or hand throttle sends instead of the pedal.· Lost messageLost messageCheck soonCauses
- Machine controller stopped sending the speed request
- CAN wiring fault
- Power loss on the machine controller
Checks
- 1Check the supply and ground of the machine controller that sends the speed request
- 2Measure CAN-H to CAN-L resistance at the diagnostic plug and check the terminators
- 3Watch for the speed request message in SerDia while the machine asks for a speed change
- 4Check the CAN wires for chafing and loose connectors
- 5Check the source of the speed request and its CAN wires.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine - CAN Wastegate actuator2 codes
Deutz SPN 523788 FMI 0Engine - CAN Wastegate actuator: Reading too high· most severe
The EMR4 rates the CAN Wastegate actuator (exchanged with the wastegate actuator over CAN) as above its allowed operating range, at the most severe level. The value may be real, or a plausibility limit has tripped. Deutz list: KWP codes 1299 and 1300, blink code 655. The wastegate actuator reports a value above its range, such as a position or current the controller does not accept.· Real conditionReal conditionCheck soonCauses
- The monitored condition is really above its limit, for example from overload or a blockage
- Signal or part drifting high with age
Checks
- 1Read the CAN Wastegate actuator value in SerDia and compare it with an independent measurement before replacing parts
- 2Look for the real cause of an excessive value, such as a restriction or an overloaded function
- 3Read the wastegate position in SerDia and compare it with the target.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - CAN Wastegate actuator - Data above normal operational range (Most severe level)
Deutz SPN 523788 FMI 12Engine - CAN Wastegate actuator: Bad device or component
The EMR4 judges the CAN Wastegate actuator (exchanged with the wastegate actuator over CAN) to be a bad device. The part or its electronics no longer respond as a working component. Deutz list: KWP code 299, blink code 655. The electric wastegate actuator reports a bad device state over CAN, so the actuator electronics report their own fault.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the part or its electronics
- Water, soot or dirt inside the part
Checks
- 1Read the CAN Wastegate actuator status in SerDia and run any available actuator or component test
- 2Check supply voltage and ground at the connector with the key on to confirm it is powered
- 3Check the supply and ground at the wastegate actuator, then swap it with a known good one.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - CAN Wastegate actuator - Bad intelligent device or component
Engine - CAN EGR actuator4 codes
Deutz SPN 524106 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout
Same fault as SPN 524108 FMI 9 for the CAN EGR actuator message. The EGR actuator message carries the valve position and status, and the valve is in the hottest part of the engine. Deutz list: KWP code 1677, blink code 195.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the heat damage on the CAN stub and plug of the EGR actuator.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524107 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout
Same fault as SPN 524108 FMI 9 for the CAN EGR actuator message. The EGR actuator message carries the valve position and status, and the valve is in the hottest part of the engine. Deutz list: KWP code 1678, blink code 931.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the heat damage on the CAN stub and plug of the EGR actuator.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524108 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout
The EMR4 did not receive the CAN EGR actuator (exchanged with the actuator over CAN) within the expected time. The data comes from another control unit on the bus, so the fault sits in the bus, the sender or its supply rather than in an engine sensor. Deutz list: KWP code 1669, blink code 932. The EGR actuator message carries the valve position and status, and the valve is in the hottest part of the engine.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the supply and ground of the sending control unit with the key on
- 2Measure the bus resistance with the key off and look for a missing terminating resistor
- 3Check the heat damage on the CAN stub and plug of the EGR actuator.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524109 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout
Same fault as SPN 524108 FMI 9 for the CAN EGR actuator message. The EGR actuator message carries the valve position and status, and the valve is in the hottest part of the engine. Deutz list: KWP code 1679, blink code 933.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the heat damage on the CAN stub and plug of the EGR actuator.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine - Exhaust throttle flap1 code
Deutz SPN 524110 FMI 9Engine - Exhaust throttle flap: Abnormal update rate timeout
The EMR4 did not receive the exhaust throttle flap (exchanged with the actuator over CAN) within the expected time. The data comes from another control unit on the bus, so the fault sits in the bus, the sender or its supply rather than in an engine sensor. Deutz list: KWP code 1670, blink code 934. The exhaust throttle flap message carries the position of the flap that raises exhaust back pressure for warm-up or braking.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the supply and ground of the sending control unit with the key on
- 2Measure the bus resistance with the key off and look for a missing terminating resistor
- 3Check that the exhaust throttle flap moves freely and has supply.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine - Exhaust brake flap1 code
Deutz SPN 524111 FMI 9Engine - Exhaust brake flap: Abnormal update rate timeout
The EMR4 did not receive the exhaust brake flap (exchanged with the actuator over CAN) within the expected time. The data comes from another control unit on the bus, so the fault sits in the bus, the sender or its supply rather than in an engine sensor. Deutz list: KWP code 1680, blink code 935. The exhaust brake flap message carries the state of the flap used for engine braking.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the supply and ground of the sending control unit with the key on
- 2Measure the bus resistance with the key off and look for a missing terminating resistor
- 3Check that the exhaust brake flap moves freely and has supply.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine - CAN throttle valve2 codes
Deutz SPN 524112 FMI 9Engine - CAN throttle valve: Abnormal update rate timeout
The EMR4 did not receive the CAN throttle valve (exchanged with the actuator over CAN) within the expected time. The data comes from another control unit on the bus, so the fault sits in the bus, the sender or its supply rather than in an engine sensor. Deutz list: KWP code 1671, blink code 936. The CAN throttle valve message carries the position and status of the intake throttle valve.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the supply and ground of the sending control unit with the key on
- 2Measure the bus resistance with the key off and look for a missing terminating resistor
- 3Check supply and ground at the intake throttle valve and its CAN plug.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524113 FMI 9Engine - CAN throttle valve: Abnormal update rate timeout
Same fault as SPN 524112 FMI 9 for the CAN throttle valve message. The CAN throttle valve message carries the position and status of the intake throttle valve. Deutz list: KWP code 1681, blink code 937.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check supply and ground at the intake throttle valve and its CAN plug.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine - CAN wastegate actuator2 codes
Deutz SPN 524121 FMI 9Engine - CAN wastegate actuator: Abnormal update rate timeout
The EMR4 did not receive the CAN wastegate actuator (exchanged with the wastegate actuator over CAN) within the expected time. The data comes from another control unit on the bus, so the fault sits in the bus, the sender or its supply rather than in an engine sensor. Deutz list: KWP code 1683, blink code 945. The wastegate actuator message is the status and position the electric actuator sends back, and it has timed out.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the supply and ground of the sending control unit with the key on
- 2Measure the bus resistance with the key off and look for a missing terminating resistor
- 3Check the supply, the CAN stub and the heat shield of the wastegate actuator.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524125 FMI 9Engine - CAN wastegate actuator: Abnormal update rate timeout
Same fault as SPN 524121 FMI 9 for the CAN wastegate actuator message. The wastegate actuator message is the status and position the electric actuator sends back, and it has timed out. Deutz list: KWP code 1687, blink code 949.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the supply, the CAN stub and the heat shield of the wastegate actuator.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Read the status of the machine controller or actuator first, since it is the sender
- 2Measure CAN high to CAN low resistance with the key off and compare it with the machine wiring diagram
- 3Wiggle the CAN harness near the connector while watching the message status in SerDia
- 4Measure supply and ground at the actuator connector with the key on
- 5Look at the requested speed and torque in SerDia and see whether they drop to a default when the code is active
Causes
- Machine controller or smart actuator not sending because it is in a fault state or has lost its supply
- CAN high or CAN low wire open, chafed or shorted, or a terminating resistor missing
- Connector with a pushed-back pin or water inside
- Actuator stuck with soot and reporting a fault on the bus
Most codes here: lost message (22 of 24)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: A warning lamp or limited function.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.