EF Logo

Detroit · Aftertreatment

Detroit NOx sensor after the SCR (outlet) fault codes

The outlet NOx sensor sits after the SCR catalyst and tells the ACM how much NOx still leaves the exhaust. Detroit lists its signal, heater, control, lambda and oxygen pump diagnostics (SPN 3226, 3227, 3238, 5713, 520355, 520365 to 520368).

FaultCheckSPN 3057FMI 2Detroit · Selective Catalyst Reduction Outlet NOx Sensor
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.

What do these codes mean?

Detroit codes SPN 3057 FMI 2 to SPN 520368 FMI 31 are all about the nOx sensor after the SCR (outlet). Most are erratic or implausible faults; none needs an immediate stop. Start with this check: read the outlet NOx value with the engine warm and compare it with the inlet value in the tool; both should move together under load.

How urgent are they?

None of the 21 codes here means stop now; all 21 can wait until the shift ends, but find the cause before the next one.

  • Check soon21

What should I check first?

Read the outlet NOx value with the engine warm and compare it with the inlet value in the tool; both should move together under load.

Shared checks

21 of 21

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Detroit SPN 3057 FMI 2Selective Catalyst Reduction Outlet NOx Sensor - Error

    Detroit lists SPN 3057 FMI 2 as "Selective Catalyst Reduction Outlet NOx Sensor - Error".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting NOx sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
    3. 3Compare the outlet NOx sensor with the inlet sensor with the engine idling to see which one is reporting an error.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 3226 FMI 8NOx Out Sensor Operation Not Stable

    Detroit lists SPN 3226 FMI 8 as "NOx Out Sensor Operation Not Stable".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting NOx sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
    3. 3The outlet NOx signal is unstable; check the connector and the exhaust for leaks that let air move past the sensor.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 3226 FMI 10NOx Out Sensor Signal Erratic

    Detroit lists SPN 3226 FMI 10 as "NOx Out Sensor Signal Erratic".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting NOx sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
    3. 3The outlet NOx signal is erratic; check the sensor connector and the CAN data for dropouts.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 3226 FMI 13Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available

    Detroit lists SPN 3226 FMI 13 as "Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available".· Part or controller
    Check soon

    Causes

    • Sensor aged, contaminated or out of calibration
    • A real fault in the system being measured

    Checks

    1. 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
    2. 2Check the system around the NOx sensor for leaks, restrictions or contamination.
    3. 3No outlet NOx signal on the CAN; check the sensor power, ground and CAN wires and the sensor control unit.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 3226 FMI 20NOx Out Sensor Diagnosis Oxygen Pump Capacity High

    Detroit lists SPN 3226 FMI 20 as "NOx Out Sensor Diagnosis Oxygen Pump Capacity High".· Erratic or implausible
    Check soon

    Causes

    • Sensor aged, contaminated or out of calibration
    • A real fault in the system being measured

    Checks

    1. 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
    2. 2Check the system around the NOx sensor for leaks, restrictions or contamination.
    3. 3The outlet NOx oxygen pump capacity is too high; the sensor cell is ageing, so test its response and replace it.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 3226 FMI 21NOx Out Sensor Diagnosis Oxygen Pump Capacity Low

    Detroit lists SPN 3226 FMI 21 as "NOx Out Sensor Diagnosis Oxygen Pump Capacity Low".· Erratic or implausible
    Check soon

    Causes

    • Sensor aged, contaminated or out of calibration
    • A real fault in the system being measured

    Checks

    1. 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
    2. 2Check the system around the NOx sensor for leaks, restrictions or contamination.
    3. 3The outlet NOx oxygen pump capacity is too low; the sensor cell has weakened, so replace the sensor if the wiring is good.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 3227 FMI 2Lambda Reading Rationality Check

    Detroit lists SPN 3227 FMI 2 as "Lambda Reading Rationality Check".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting NOx sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
    3. 3The lambda reading from the outlet sensor does not match the exhaust state; check for exhaust leaks and the sensor lambda circuit.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 3227 FMI 3Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed High

    Detroit lists SPN 3227 FMI 3 as "Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed High".· Shorted high
    Check soon

    Causes

    • Signal wire shorted to the 5 V supply or open between the NOx sensor and the ACM
    • The NOx sensor has failed inside

    Checks

    1. 1Unplug the NOx sensor and measure the signal pin; a reading near supply with the sensor off means the harness is shorted or open.
    2. 2Bridge the signal to the return with the sensor unplugged; the reading should fall away if the harness is good.
    3. 3The outlet sensor lambda 1 circuit is shorted high; check its wire for a short to supply.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 3227 FMI 5Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed Open

    Detroit lists SPN 3227 FMI 5 as "Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed Open".· Open circuit
    Check soon

    Causes

    • Broken wire or a pushed-out pin in the NOx sensor connector
    • Corroded terminal or a failed sensor

    Checks

    1. 1Check continuity of every wire between the NOx sensor connector and the ACM connector.
    2. 2Wiggle the harness and connector while watching the live value for dropouts.
    3. 3The outlet sensor lambda 1 circuit is open; check the connector and the lambda wire for a break.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Detroit SPN 3238 FMI 2Selective Catalyst Reduction Outlet NOx Sensor Failure to Activate

    Detroit lists SPN 3238 FMI 2 as "Selective Catalyst Reduction Outlet NOx Sensor Failure to Activate".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting NOx sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
    3. 3The outlet NOx sensor did not become active; check the sensor heater circuit and supply voltage after a cold start.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 5713 FMI 20NOx Out Sensor Self-diagnosis NOx Drifted High

    Detroit lists SPN 5713 FMI 20 as "NOx Out Sensor Self-diagnosis NOx Drifted High".· Erratic or implausible
    Check soon

    Causes

    • Sensor aged, contaminated or out of calibration
    • A real fault in the system being measured

    Checks

    1. 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
    2. 2Check the system around the NOx sensor for leaks, restrictions or contamination.
    3. 3The outlet NOx self-diagnosis drift is high; replace the outlet sensor if the exhaust is clean.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 5713 FMI 21NOx Out Sensor Self-Diagnosis NOx Drifted Low

    Detroit lists SPN 5713 FMI 21 as "NOx Out Sensor Self-Diagnosis NOx Drifted Low".· Erratic or implausible
    Check soon

    Causes

    • Sensor aged, contaminated or out of calibration
    • A real fault in the system being measured

    Checks

    1. 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
    2. 2Check the system around the NOx sensor for leaks, restrictions or contamination.
    3. 3The outlet NOx self-diagnosis drift is low; replace the outlet sensor if the exhaust is clean.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 520355 FMI 14NOx Out Sensor Does Not Support Self Diagnosis

    Detroit lists SPN 520355 FMI 14 as "NOx Out Sensor Does Not Support Self Diagnosis".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting NOx sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
    3. 3The outlet NOx sensor does not support self-diagnosis; check that the correct sensor part is fitted.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 520355 FMI 20NOx Outlet Sensor Diagnosis Oxygen Pump Capacity High

    Same failure as SPN 3226 FMI 20 ("NOx Out Sensor Diagnosis Oxygen Pump Capacity High") on a sibling part: Detroit lists SPN 520355 FMI 20 as "NOx Outlet Sensor Diagnosis Oxygen Pump Capacity High".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 3226 FMI 20, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3226 FMI 20, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 520355 FMI 21NOx Outlet Sensor Diagnosis Oxygen Pump Capacity Low

    Same failure as SPN 3226 FMI 21 ("NOx Out Sensor Diagnosis Oxygen Pump Capacity Low") on a sibling part: Detroit lists SPN 520355 FMI 21 as "NOx Outlet Sensor Diagnosis Oxygen Pump Capacity Low".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 3226 FMI 21, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3226 FMI 21, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 520365 FMI 3Selective Catalyst Reduction Outlet NOx Sensor Heater Circuit Failed High

    Same failure as SPN 3227 FMI 3 ("Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed High") on a sibling part: Detroit lists SPN 520365 FMI 3 as "Selective Catalyst Reduction Outlet NOx Sensor Heater Circuit Failed High".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 3227 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3227 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 520365 FMI 5Selective Catalyst Reduction Outlet NOx Sensor Heater Circuit Failed Open

    Same failure as SPN 3227 FMI 5 ("Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed Open") on a sibling part: Detroit lists SPN 520365 FMI 5 as "Selective Catalyst Reduction Outlet NOx Sensor Heater Circuit Failed Open".· Open circuit
    Check soon

    Causes

    • The causes listed under SPN 3227 FMI 5, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3227 FMI 5, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Detroit SPN 520366 FMI 3Selective Catalyst Reduction Outlet NOx Sensor Control Circuit Failed High

    Same failure as SPN 3227 FMI 3 ("Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed High") on a sibling part: Detroit lists SPN 520366 FMI 3 as "Selective Catalyst Reduction Outlet NOx Sensor Control Circuit Failed High".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 3227 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3227 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 520366 FMI 5Selective Catalyst Reduction Outlet NOx Sensor Control Circuit Failed Open

    Same failure as SPN 3227 FMI 5 ("Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed Open") on a sibling part: Detroit lists SPN 520366 FMI 5 as "Selective Catalyst Reduction Outlet NOx Sensor Control Circuit Failed Open".· Open circuit
    Check soon

    Causes

    • The causes listed under SPN 3227 FMI 5, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3227 FMI 5, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Detroit SPN 520368 FMI 14Selective Catalyst Reduction Outlet NOx Sensor Lambda 2 Circuit Failed Open

    Same failure as SPN 3227 FMI 5 ("Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed Open") on a sibling part: Detroit lists SPN 520368 FMI 14 as "Selective Catalyst Reduction Outlet NOx Sensor Lambda 2 Circuit Failed Open".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 3227 FMI 5, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3227 FMI 5, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 520368 FMI 31Selective Catalyst Reduction Outlet NOx Sensor Lambda 2 Circuit Failed High

    Same failure as SPN 3227 FMI 3 ("Selective Catalyst Reduction Outlet NOx Sensor Lambda 1 Circuit Failed High") on a sibling part: Detroit lists SPN 520368 FMI 31 as "Selective Catalyst Reduction Outlet NOx Sensor Lambda 2 Circuit Failed High".· Real condition
    Check soon

    Causes

    • The causes listed under SPN 3227 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3227 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Read the outlet NOx value with the engine warm and compare it with the inlet value in the tool; both should move together under load.
  2. 2Inspect the outlet sensor connector and the harness near the muffler for heat damage, oil and corrosion.
  3. 3Check the exhaust for leaks upstream of the sensor, because leaking air gives false readings.
  4. 4Check the sensor control unit supply and ground, then replace the sensor if the wiring is good.

Causes

  • Outlet NOx sensor worn out or contaminated by exhaust soot
  • Sensor heater or control wiring open or shorted at the sensor connector
  • Exhaust leak between the SCR and the sensor tip
  • Dosing or catalyst fault that shows up first at the outlet

Most codes here: erratic or implausible (12 of 21)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: A check-engine lamp and, if the conversion cannot be proven, a staged derate.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?