Detroit SCR catalyst temperature and NOx conversion fault codes

The ACM monitors the temperatures around the SCR catalyst and the conversion efficiency. Detroit logs sensor faults and low-efficiency conditions.

FaultCheckSPN 4364FMI 1Detroit · SCR catalyst temperature and NOx conversion
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.

What do these codes mean?

Detroit codes SPN 4360 FMI 15 to SPN 520372 FMI 16 are all about the sCR catalyst temperature and NOx conversion. The most common failure type is real condition (8 of 17); none needs an immediate stop. Start with this check: check the DEF quality and the dosing rate before blaming the catalyst.

How urgent are they?

None of the 17 codes here means stop now; all 17 can wait until the shift ends, but find the cause before the next one.

  • Check soon17

What should I check first?

Check the DEF quality and the dosing rate before blaming the catalyst.

Shared checks

17 of 17

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Detroit SPN 4360 FMI 15Selective Catalyst Reduction Inlet Temperature High

    Detroit lists SPN 4360 FMI 15 as "Selective Catalyst Reduction Inlet Temperature High".· Real condition
    Check soon

    Causes

    • A real fault in the system the SCR temperature or conversion signal measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the SCR temperature or conversion signal.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4360 FMI 20Selective Catalyst Reduction Inlet Temperature Sensor Drift High in Range

    Detroit lists SPN 4360 FMI 20 as "Selective Catalyst Reduction Inlet Temperature Sensor Drift High in Range".· Erratic or implausible
    Check soon

    Causes

    • Sensor aged, contaminated or out of calibration
    • A real fault in the system being measured

    Checks

    1. 1Compare the SCR temperature or conversion signal reading with a reference gauge or thermometer with the engine off and cold.
    2. 2Check the system around the SCR temperature or conversion signal for leaks, restrictions or contamination.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 4360 FMI 31Selective Catalyst Reduction Inlet Temperature Not Warming Up

    Detroit lists SPN 4360 FMI 31 as "Selective Catalyst Reduction Inlet Temperature Not Warming Up".· Real condition
    Check soon

    Causes

    • A real fault in the system the SCR temperature or conversion signal watches
    • Sensor or wiring fault

    Checks

    1. 1Read the live value and compare it with a reference.
    2. 2Check the connector and wiring.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4363 FMI 0SCR Outlet Temperature High

    Detroit lists SPN 4363 FMI 0 as "SCR Outlet Temperature High".· Real condition
    Check soon

    Causes

    • A real fault in the system the SCR temperature or conversion signal measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the SCR temperature or conversion signal.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4363 FMI 2Selective Catalyst Reduction Outlet Temperature - Not Plausible

    Detroit lists SPN 4363 FMI 2 as "Selective Catalyst Reduction Outlet Temperature - Not Plausible".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting SCR temperature or conversion signal or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the SCR temperature or conversion signal reading with a second reference such as a gauge or another sensor on the engine.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 4363 FMI 3Selective Catalyst Reduction Outlet Temperature Sensor Circuit Failed High

    Detroit lists SPN 4363 FMI 3 as "Selective Catalyst Reduction Outlet Temperature Sensor Circuit Failed High".· Shorted high
    Check soon

    Causes

    • Signal wire shorted to the 5 V supply or open between the SCR temperature or conversion signal and the ACM
    • The SCR temperature or conversion signal has failed inside

    Checks

    1. 1Unplug the SCR temperature or conversion signal and measure the signal pin; a reading near supply with the sensor off means the harness is shorted or open.
    2. 2Bridge the signal to the return with the sensor unplugged; the reading should fall away if the harness is good.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 4363 FMI 4Selective Catalyst Reduction Outlet Temperature Sensor Circuit Failed Low

    Detroit lists SPN 4363 FMI 4 as "Selective Catalyst Reduction Outlet Temperature Sensor Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • Signal wire chafed against the engine and shorted to ground
    • The SCR temperature or conversion signal has failed inside or its supply wire is open

    Checks

    1. 1Unplug the SCR temperature or conversion signal and check whether the signal rises; if it stays low the harness is shorted to ground.
    2. 2Check the sensor supply at the connector with the key on and trace it back to the ACM if it is missing.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 4363 FMI 8SCR Outlet Temperature Signal Spike

    Detroit lists SPN 4363 FMI 8 as "SCR Outlet Temperature Signal Spike".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting SCR temperature or conversion signal or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the SCR temperature or conversion signal reading with a second reference such as a gauge or another sensor on the engine.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 4363 FMI 10SCR Outlet Temperature Sensor - Rationality Error

    Same failure as SPN 4363 FMI 2 ("Selective Catalyst Reduction Outlet Temperature - Not Plausible") on a sibling part: Detroit lists SPN 4363 FMI 10 as "SCR Outlet Temperature Sensor - Rationality Error".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 4363 FMI 2, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 4363 FMI 2, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 4363 FMI 20SCR Temperature Drift - Inlet Low/Outlet High

    Same failure as SPN 4360 FMI 20 ("Selective Catalyst Reduction Inlet Temperature Sensor Drift High in Range") on a sibling part: Detroit lists SPN 4363 FMI 20 as "SCR Temperature Drift - Inlet Low/Outlet High".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 4360 FMI 20, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 4360 FMI 20, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 4364 FMI 1SCR NOx Conversion Efficiency Very Low

    The ACM calculated that the SCR catalyst is converting NOx at a very low efficiency.· Real condition
    Check soon

    Causes

    • Poor DEF quality or dilute fluid
    • Plugged or leaking DEF doser, or insufficient dosing
    • Failed or drifting NOx sensors giving a wrong efficiency
    • Aged or damaged SCR catalyst

    Checks

    1. 1Test the DEF concentration with a refractometer and replace the fluid if it is dilute.
    2. 2Inspect the doser nozzle for crystal build-up and check the DEF lines.
    3. 3Compare the inlet and outlet NOx sensor values in the tool; they should differ when dosing works.
    4. 4Check the exhaust for leaks between the turbo and the catalyst.
    5. 5Only replace the catalyst after dosing, quality and sensors are proven good.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4364 FMI 17SCR NOx Conversion Efficiency

    Detroit lists SPN 4364 FMI 17 as "SCR NOx Conversion Efficiency".· Real condition
    Check soon

    Causes

    • A real fault in the system the SCR temperature or conversion signal measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the SCR temperature or conversion signal.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4364 FMI 31SCR NOx Efficiency Low

    Detroit lists SPN 4364 FMI 31 as "SCR NOx Efficiency Low".· Real condition
    Check soon

    Causes

    • A real fault in the system the SCR temperature or conversion signal watches
    • Sensor or wiring fault

    Checks

    1. 1Read the live value and compare it with a reference.
    2. 2Check the connector and wiring.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 5298 FMI 14Selective Catalytic Reduction Catalyst Abnormal Temperature Rise

    Detroit lists SPN 5298 FMI 14 as "Selective Catalytic Reduction Catalyst Abnormal Temperature Rise".· Lost message
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting SCR temperature or conversion signal or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the SCR temperature or conversion signal reading with a second reference such as a gauge or another sensor on the engine.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 520371 FMI 16Selective Catalyst Reduction Closed Loop Control at Maximum Limit (Multiples Sources)

    Detroit lists SPN 520371 FMI 16 as "Selective Catalyst Reduction Closed Loop Control at Maximum Limit (Multiples Sources)".· Real condition
    Check soon

    Causes

    • A real fault in the system the SCR temperature or conversion signal measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the SCR temperature or conversion signal.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520372 FMI 14Selective Catalyst Reduction Closed Loop Control at Maximum Limit (Timeout)

    Detroit lists SPN 520372 FMI 14 as "Selective Catalyst Reduction Closed Loop Control at Maximum Limit (Timeout)".· Lost message
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting SCR temperature or conversion signal or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the SCR temperature or conversion signal reading with a second reference such as a gauge or another sensor on the engine.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 520372 FMI 16Selective Catalyst Reduction Closed Loop Control at Maximum Limit

    Detroit lists SPN 520372 FMI 16 as "Selective Catalyst Reduction Closed Loop Control at Maximum Limit".· Real condition
    Check soon

    Causes

    • A real fault in the system the SCR temperature or conversion signal measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the SCR temperature or conversion signal.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Check the DEF quality and the dosing rate before blaming the catalyst.
  2. 2Read both NOx sensors in the diagnostic tool and compare inlet with outlet.
  3. 3Inspect the SCR temperature sensors and their connectors for damage.
  4. 4Check the exhaust for leaks between the turbo and the catalyst.

Causes

  • Poor DEF quality or dosing
  • NOx sensor error
  • Catalyst damage
  • Temperature sensor fault

Most common here: real condition (8 of 17)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A check-engine lamp, a derate and in some cases the DEF inducement stages on the dash.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.