Detroit · Aftertreatment
Detroit NOx sensor ahead of the SCR (inlet) fault codes
The inlet NOx sensor sits before the SCR catalyst and gives the ACM the engine-out NOx value it needs to calculate the DEF dose. Detroit lists its signal, heater, control, lambda, drift and oxygen pump faults (SPN 3056, 3216, 3217, 3223, 5714, 520363, 520364, 520367) and the integrated NOx flow codes.
Where to read it
Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.
What do these codes mean?
Detroit codes SPN 3056 FMI 2 to SPN 521173 FMI 21 are all about the nOx sensor ahead of the SCR (inlet). The most common failure type is erratic or implausible (12 of 24); none needs an immediate stop. Start with this check: read the inlet NOx value in the tool with the engine idling and compare it with the expected engine-out level.
How urgent are they?
None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.
- Check soon24
What should I check first?
Read the inlet NOx value in the tool with the engine idling and compare it with the expected engine-out level.
Shared checks24 of 24
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Detroit SPN 3056 FMI 2Selective Catalyst Reduction Inlet NOx Sensor - Error
Detroit lists SPN 3056 FMI 2 as "Selective Catalyst Reduction Inlet NOx Sensor - Error". The ACM judged the NOx sensor reading erratic or not plausible compared with other sensors or its own history. The SCR inlet NOx sensor reports the NOx leaving the engine; the ACM uses it to set the DEF dose.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Loose or corroded connector causing a noisy signal
- A drifting NOx sensor or a related fault in the part it measures
Checks
- 1Watch the live value while wiggling the harness to find an intermittent connection.
- 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3216 FMI 2NOx Sensor Response is Slow
The inlet NOx sensor answered slowly or did not follow the change in NOx that the ACM expects. A sensor that responds too slowly makes the DEF dosing inaccurate.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Inlet NOx sensor worn out or contaminated
- Sensor heater not warming the element
- Exhaust leak near the sensor
- Wiring or CAN problem between the sensor control unit and the ACM
Checks
- 1Read the inlet NOx value in the tool during a throttle snap and see whether it follows the engine load.
- 2Inspect the sensor connector and harness near the turbo outlet for heat damage and oil.
- 3Check the exhaust around the sensor for leaks that let outside air into the exhaust stream.
- 4Check the sensor control unit supply and ground with the key on.
- 5Replace the sensor if the wiring is good and the response stays slow after a warm-up drive.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3216 FMI 8NOx Raw Sensor Operation Not Stable
Detroit lists SPN 3216 FMI 8 as "NOx Raw Sensor Operation Not Stable". The ACM judged the NOx sensor reading erratic or not plausible compared with other sensors or its own history. The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Loose or corroded connector causing a noisy signal
- A drifting NOx sensor or a related fault in the part it measures
Checks
- 1Watch the live value while wiggling the harness to find an intermittent connection.
- 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3216 FMI 10NOx Raw Sensor Signal Erratic
Detroit lists SPN 3216 FMI 10 as "NOx Raw Sensor Signal Erratic". The ACM judged the NOx sensor reading erratic or not plausible compared with other sensors or its own history. The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Loose or corroded connector causing a noisy signal
- A drifting NOx sensor or a related fault in the part it measures
Checks
- 1Watch the live value while wiggling the harness to find an intermittent connection.
- 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3216 FMI 13Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit lists SPN 3216 FMI 13 as "Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available". The ACM found the NOx sensor value drifted away from what the engine state says it should be. The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Part or controllerPart or controllerCheck soonCauses
- Sensor aged, contaminated or out of calibration
- A real fault in the system being measured
Checks
- 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
- 2Check the system around the NOx sensor for leaks, restrictions or contamination.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 3216 FMI 14NOx Close Loop Control Error
Detroit lists SPN 3216 FMI 14 as "NOx Close Loop Control Error". The ACM judged the NOx sensor reading erratic or not plausible compared with other sensors or its own history. The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Loose or corroded connector causing a noisy signal
- A drifting NOx sensor or a related fault in the part it measures
Checks
- 1Watch the live value while wiggling the harness to find an intermittent connection.
- 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3216 FMI 16Selective Catalyst Reduction Inlet NOx Sensor - Drift High
Detroit lists SPN 3216 FMI 16 as "Selective Catalyst Reduction Inlet NOx Sensor - Drift High". The ACM reports that the measured value itself is out of its normal range; the NOx sensor may be correct and a real condition may exist. The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Real conditionReal conditionCheck soonCauses
- A real fault in the system the NOx sensor measures
- Sensor reading skewed by a wiring or connector problem
Checks
- 1Confirm the real value with a mechanical gauge or an independent reading before replacing the NOx sensor.
- 2Check the system for the condition the code describes and fix it first.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 3216 FMI 20SCR NOx Inlet Sensor Drift High
Same failure as SPN 3216 FMI 16 ("Selective Catalyst Reduction Inlet NOx Sensor - Drift High") on a sibling part: Detroit lists SPN 3216 FMI 20 as "SCR NOx Inlet Sensor Drift High". The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Erratic or implausibleErratic or implausibleCheck soonCauses
- The causes listed under SPN 3216 FMI 16, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3216 FMI 16, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3216 FMI 21NOx Raw Sensor Diagnosis Oxygen Pump Capacity Low
Detroit lists SPN 3216 FMI 21 as "NOx Raw Sensor Diagnosis Oxygen Pump Capacity Low". The ACM found the NOx sensor value drifted away from what the engine state says it should be. The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor aged, contaminated or out of calibration
- A real fault in the system being measured
Checks
- 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
- 2Check the system around the NOx sensor for leaks, restrictions or contamination.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3216 FMI 31NOx Close Loop Control Functional Error
Detroit lists SPN 3216 FMI 31 as "NOx Close Loop Control Functional Error". The ACM logged a condition on the NOx sensor; the title says what it measured. The inlet NOx sensor reports NOx and oxygen through its own control unit, so slow response, drift and signal loss are judged on the sensor data the ACM receives.· Real conditionReal conditionCheck soonCauses
- A real fault in the system the NOx sensor watches
- Sensor or wiring fault
Checks
- 1Read the live value and compare it with a reference.
- 2Check the connector and wiring.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 3217 FMI 2Engine Out Lambda Signal Lower Than Expected in Engine No-Fueling Mode
Detroit lists SPN 3217 FMI 2 as "Engine Out Lambda Signal Lower Than Expected in Engine No-Fueling Mode". The ACM judged the NOx sensor reading erratic or not plausible compared with other sensors or its own history. The inlet sensor also reports a lambda (oxygen) value from its first measuring cell; a circuit fault here shows as a lambda 1 high or open code.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Loose or corroded connector causing a noisy signal
- A drifting NOx sensor or a related fault in the part it measures
Checks
- 1Watch the live value while wiggling the harness to find an intermittent connection.
- 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 3217 FMI 3Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed High
Detroit lists SPN 3217 FMI 3 as "Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed High". The ACM saw the NOx sensor signal above its valid range. That usually means the signal wire is shorted to a supply voltage or is open at the sensor. The inlet sensor also reports a lambda (oxygen) value from its first measuring cell; a circuit fault here shows as a lambda 1 high or open code.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V supply or open between the NOx sensor and the ACM
- The NOx sensor has failed inside
Checks
- 1Unplug the NOx sensor and measure the signal pin; a reading near supply with the sensor off means the harness is shorted or open.
- 2Bridge the signal to the return with the sensor unplugged; the reading should fall away if the harness is good.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3217 FMI 5Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed Open
Detroit lists SPN 3217 FMI 5 as "Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed Open". The ACM detected an open circuit on the NOx sensor line, so the signal floats or is missing. The inlet sensor also reports a lambda (oxygen) value from its first measuring cell; a circuit fault here shows as a lambda 1 high or open code.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pushed-out pin in the NOx sensor connector
- Corroded terminal or a failed sensor
Checks
- 1Check continuity of every wire between the NOx sensor connector and the ACM connector.
- 2Wiggle the harness and connector while watching the live value for dropouts.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 3223 FMI 7NOx Inlet Sensor Failure to Activate
Detroit lists SPN 3223 FMI 7 as "NOx Inlet Sensor Failure to Activate". The ACM judged the NOx sensor reading erratic or not plausible compared with other sensors or its own history. The inlet NOx sensor must reach operating temperature after start; failure to activate means the heater or element never became ready.· Part or controllerPart or controllerCheck soonCauses
- Loose or corroded connector causing a noisy signal
- A drifting NOx sensor or a related fault in the part it measures
Checks
- 1Watch the live value while wiggling the harness to find an intermittent connection.
- 2Compare the NOx sensor reading with a second reference such as a gauge or another sensor on the engine.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 5714 FMI 20NOx Raw Sensor Self-Diagnosis NOx Drifted High
Same failure as SPN 3216 FMI 16 ("Selective Catalyst Reduction Inlet NOx Sensor - Drift High") on a sibling part: Detroit lists SPN 5714 FMI 20 as "NOx Raw Sensor Self-Diagnosis NOx Drifted High". NOx inlet (raw) sensor self-diagnosis checks the sensor drift in the same way.· Erratic or implausibleErratic or implausibleCheck soonCauses
- The causes listed under SPN 3216 FMI 16, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3216 FMI 16, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 5714 FMI 21NOx Raw Sensor Self-Diagnosis NOx Drifted Low
Detroit lists SPN 5714 FMI 21 as "NOx Raw Sensor Self-Diagnosis NOx Drifted Low". The ACM found the NOx sensor value drifted away from what the engine state says it should be. NOx inlet (raw) sensor self-diagnosis checks the sensor drift in the same way.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor aged, contaminated or out of calibration
- A real fault in the system being measured
Checks
- 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
- 2Check the system around the NOx sensor for leaks, restrictions or contamination.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 520363 FMI 3Selective Catalyst Reduction Inlet NOx Sensor Heater Circuit Failed High
Same failure as SPN 3217 FMI 3 ("Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed High") on a sibling part: Detroit lists SPN 520363 FMI 3 as "Selective Catalyst Reduction Inlet NOx Sensor Heater Circuit Failed High". The inlet NOx sensor heater circuit is open or shorted high.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3217 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3217 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 520363 FMI 5Selective Catalyst Reduction Inlet NOx Sensor Heater Circuit Failed Open
Same failure as SPN 3217 FMI 5 ("Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed Open") on a sibling part: Detroit lists SPN 520363 FMI 5 as "Selective Catalyst Reduction Inlet NOx Sensor Heater Circuit Failed Open". The inlet NOx sensor heater circuit is open or shorted high.· Open circuitOpen circuitCheck soonCauses
- The causes listed under SPN 3217 FMI 5, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3217 FMI 5, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 520364 FMI 3Selective Catalyst Reduction Inlet NOx Sensor Control Circuit Failed High
Same failure as SPN 3217 FMI 3 ("Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed High") on a sibling part: Detroit lists SPN 520364 FMI 3 as "Selective Catalyst Reduction Inlet NOx Sensor Control Circuit Failed High". The inlet NOx sensor control circuit is open or shorted high.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3217 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3217 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 520364 FMI 5Selective Catalyst Reduction Inlet NOx Sensor Control Circuit Failed Open
Same failure as SPN 3217 FMI 5 ("Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed Open") on a sibling part: Detroit lists SPN 520364 FMI 5 as "Selective Catalyst Reduction Inlet NOx Sensor Control Circuit Failed Open". The inlet NOx sensor control circuit is open or shorted high.· Open circuitOpen circuitCheck soonCauses
- The causes listed under SPN 3217 FMI 5, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3217 FMI 5, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 520367 FMI 3Selective Catalyst Reduction Inlet NOx Sensor Lambda 2 Circuit Failed High
Same failure as SPN 3217 FMI 3 ("Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed High") on a sibling part: Detroit lists SPN 520367 FMI 3 as "Selective Catalyst Reduction Inlet NOx Sensor Lambda 2 Circuit Failed High". The inlet NOx sensor lambda 2 circuit is open or shorted high.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3217 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3217 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 520367 FMI 5Selective Catalyst Reduction Inlet NOx Sensor Lambda 2 Circuit Failed Open
Same failure as SPN 3217 FMI 5 ("Selective Catalyst Reduction Inlet NOx Sensor Lambda 1 Circuit Failed Open") on a sibling part: Detroit lists SPN 520367 FMI 5 as "Selective Catalyst Reduction Inlet NOx Sensor Lambda 2 Circuit Failed Open". The inlet NOx sensor lambda 2 circuit is open or shorted high.· Open circuitOpen circuitCheck soonCauses
- The causes listed under SPN 3217 FMI 5, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3217 FMI 5, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 521173 FMI 20Integrated NOx Flow Rate Error Below the Allowable Threshold
Detroit lists SPN 521173 FMI 20 as "Integrated NOx Flow Rate Error Below the Allowable Threshold". The ACM found the NOx sensor value drifted away from what the engine state says it should be. Integrated NOx flow rate error below or above the allowable threshold.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor aged, contaminated or out of calibration
- A real fault in the system being measured
Checks
- 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
- 2Check the system around the NOx sensor for leaks, restrictions or contamination.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 521173 FMI 21Integrated NOx Flow Rate Error Above the Allowable Threshold
Detroit lists SPN 521173 FMI 21 as "Integrated NOx Flow Rate Error Above the Allowable Threshold". The ACM found the NOx sensor value drifted away from what the engine state says it should be. Integrated NOx flow rate error below or above the allowable threshold.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor aged, contaminated or out of calibration
- A real fault in the system being measured
Checks
- 1Compare the NOx sensor reading with a reference gauge or thermometer with the engine off and cold.
- 2Check the system around the NOx sensor for leaks, restrictions or contamination.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Shared checks
Checks, in order
- 1Read the inlet NOx value in the tool with the engine idling and compare it with the expected engine-out level.
- 2Inspect the inlet sensor connector and harness near the turbo outlet for heat damage and oil.
- 3Check the exhaust between the turbo and the sensor for leaks.
- 4Check the sensor control unit supply, ground and CAN wiring, then replace the sensor if the wiring is good.
Causes
- Inlet NOx sensor failed or drifting
- Sensor heater or control wiring open or shorted at the connector
- Exhaust leak, or a sensor fitted in a damaged pipe
- Software or CAN fault between the sensor control unit and the ACM
Most common here: erratic or implausible (12 of 24)
Watch the live value on the service tool while you flex the harness and tap the connector.
When to stop
You'll notice: A check-engine lamp, poor DEF dosing and possibly a staged derate.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Detroit Diesel DD15 Gen 5 (2023) Fault Codes List, Diesel Repair (SPN/FMI with Detroit descriptions)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
