FaultCheckSPN 3361FMI 31Detroit · DEF dosing pump, pressure and flow
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.

What do these codes mean?

Detroit codes SPN 3361 FMI 1 to SPN 520342 FMI 17 are all about the dEF dosing pump, pressure and flow. The most common failure type is real condition (8 of 24); none needs an immediate stop. Start with this check: check the DEF level and quality before testing any electrical part of the dosing unit.

How urgent are they?

None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.

  • Check soon24

What should I check first?

Check the DEF level and quality before testing any electrical part of the dosing unit.

Shared checks

24 of 24

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Detroit SPN 3361 FMI 1Automatic Self-Check of DEF Dosing System Not Done

    Detroit lists SPN 3361 FMI 1 as "Automatic Self-Check of DEF Dosing System Not Done".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The automatic self-check of the dosing system was not done; run the dosing system test in the tool.
    4. 4The self-check runs at key-off; leave the key off long enough for the system to run the check and see if it completes.
    5. 5The automatic self-check runs after key-off while the unit purges the lines, so cutting battery power during after-run can leave it unfinished.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 3361 FMI 3Diesel Exhaust Fluid System Circuit Failed High

    Detroit lists SPN 3361 FMI 3 as "Diesel Exhaust Fluid System Circuit Failed High".· Shorted high
    Check soon

    Causes

    • Output wire of the DEF pump rubbed through and touching a live wire
    • Internal short in the DEF pump

    Checks

    1. 1Unplug the DEF pump and look for voltage on the output wire with the key on.
    2. 2Measure the DEF pump winding resistance and compare it with a good unit.
    3. 3The DEF dosing system circuit is shorted high; check the unit connector and wires for a short to supply.
    4. 4High circuit: look for a short to supply in the dosing unit harness.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 3361 FMI 4Diesel Exhaust Fluid System Circuit Failed Low

    Detroit lists SPN 3361 FMI 4 as "Diesel Exhaust Fluid System Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • Output wire of the DEF pump rubbed through against the engine
    • Internal short in the DEF pump

    Checks

    1. 1Unplug the DEF pump and check the output wire for continuity to ground.
    2. 2Measure the DEF pump winding resistance and look for a very low value.
    3. 3The DEF dosing system circuit is shorted low; check the unit connector and wires for a short to ground.
    4. 4Low circuit: look for a short to ground in the dosing unit harness.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 3361 FMI 5Diesel Exhaust Fluid System Circuit Failed Open

    Detroit lists SPN 3361 FMI 5 as "Diesel Exhaust Fluid System Circuit Failed Open".· Open circuit
    Check soon

    Causes

    • Open wire or pushed-out pin at the DEF pump connector
    • Burned-out DEF pump coil

    Checks

    1. 1Check continuity from the ACM pin to the DEF pump connector and back.
    2. 2Measure the DEF pump winding resistance; an open reading means the part has failed.
    3. 3The DEF dosing system circuit is open; check the unit connector pins and the wires for a break.
    4. 4Open circuit: look for a broken wire in the dosing unit harness.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Detroit SPN 3361 FMI 31Diesel Exhaust Fluid Dosing Unit Error

    The ACM reports an error in the DEF dosing unit that it cannot classify further.· Real condition
    Check soon

    Causes

    • Dosing unit electrical or mechanical failure
    • DEF supply or pressure problem
    • Frozen DEF in the unit

    Checks

    1. 1Read all other DEF codes first; they usually point at the real cause of this general dosing fault.
    2. 2Check the DEF level and the dosing unit connector for damage and corrosion.
    3. 3Run the dosing test in the tool and compare the pump speed with the pressure.
    4. 4Inspect the dosing unit for leaks, crystals and frozen fluid.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4331 FMI 15DEF Dosing Quantity Low

    Detroit lists SPN 4331 FMI 15 as "DEF Dosing Quantity Low".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF dosing quantity is low; check the nozzle for crystals and the lines for restrictions.
    4. 4Low dosing quantity: remove the doser and look for crystals in the nozzle.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4334 FMI 3Diesel Exhaust Fluid Pressure Sensor Circuit Failed High

    Same failure as SPN 3361 FMI 3 ("Diesel Exhaust Fluid System Circuit Failed High") on a sibling part: Detroit lists SPN 4334 FMI 3 as "Diesel Exhaust Fluid Pressure Sensor Circuit Failed High".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 3361 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3361 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 4334 FMI 4Diesel Exhaust Fluid Pressure Sensor Circuit Failed Low

    Same failure as SPN 3361 FMI 4 ("Diesel Exhaust Fluid System Circuit Failed Low") on a sibling part: Detroit lists SPN 4334 FMI 4 as "Diesel Exhaust Fluid Pressure Sensor Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 3361 FMI 4, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3361 FMI 4, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 4374 FMI 0Under Pressurized Diesel Exhaust Fluid System

    The ACM found the DEF system under-pressurised: the pump cannot reach the pressure the doser needs.· Real condition
    Check soon

    Causes

    • Low DEF level or frozen fluid
    • Plugged DEF filter or crystals in the lines
    • Air in the system after a refill
    • Pump worn out

    Checks

    1. 1Check the DEF level and make sure the fluid is not frozen in the tank or in the lines.
    2. 2Inspect the DEF filter and the lines for crystals, kinks and leaks.
    3. 3Run the dosing test in the tool and watch the pump speed and the pressure.
    4. 4Check the pump connector and wiring for corrosion and damage.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4374 FMI 1Over Pressurized DEF System

    Detroit lists SPN 4374 FMI 1 as "Over Pressurized DEF System".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF system is over-pressurised; check the lines and the doser for blockage or frozen fluid.
    4. 4Over pressure: look for a blocked doser nozzle or a pinched pressure line.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 4374 FMI 3Diesel Exhaust Fluid (DEF) Pump Speed Signal Above Measurement Range

    Detroit lists SPN 4374 FMI 3 as "Diesel Exhaust Fluid (DEF) Pump Speed Signal Above Measurement Range".· Shorted high
    Check soon

    Causes

    • Output wire of the DEF pump rubbed through and touching a live wire
    • Internal short in the DEF pump

    Checks

    1. 1Unplug the DEF pump and look for voltage on the output wire with the key on.
    2. 2Measure the DEF pump winding resistance and compare it with a good unit.
    3. 3The pump speed signal is above range; check the pump speed sensor wire and the pump.
    4. 4Pump speed signal above range: check the pump speed wire and the pump for a short.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 4374 FMI 4Aftertreatment Control Module (ACM) Detects that the DEF PumpSpeed Signal is below a Calibrated Range

    Detroit lists SPN 4374 FMI 4 as "Aftertreatment Control Module (ACM) Detects that the DEF PumpSpeed Signal is below a Calibrated Range".· Shorted low
    Check soon

    Causes

    • Output wire of the DEF pump rubbed through against the engine
    • Internal short in the DEF pump

    Checks

    1. 1Unplug the DEF pump and check the output wire for continuity to ground.
    2. 2Measure the DEF pump winding resistance and look for a very low value.
    3. 3The pump speed signal is below the calibrated limit; check the pump and its speed sensor.
    4. 4Pump speed signal below range: check the pump motor and its speed wire for an open.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 4374 FMI 9DEF PSV Loop Error

    Detroit lists SPN 4374 FMI 9 as "DEF PSV Loop Error".· Lost message
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF PSV loop has an error; check the pressure sensor and the control valve.
    4. 4The PSV loop error points to the pressure control valve; check it for sticking.
    5. 5The PSV is the pressure and shut-off valve of the dosing unit; a loop error means the valve does not hold the pressure the pump builds, so listen for the valve click when the system primes.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 4374 FMI 11DEF PNV SRH Loop Error (Pump Speed Low)

    Detroit lists SPN 4374 FMI 11 as "DEF PNV SRH Loop Error (Pump Speed Low)".· Other
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF pump speed loop error with low speed; check the pump motor for binding.
    4. 4The pump runs slowly in the control loop; check the pump motor and the supply.
    5. 5A low pump speed in the control loop with the pressure still not reached suggests a pump that is weak or a suction line that sucks air, so check the line joints.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Detroit SPN 4374 FMI 14DEF PNV SRH Loop Error (Pump Speed High)

    Detroit lists SPN 4374 FMI 14 as "DEF PNV SRH Loop Error (Pump Speed High)".· Other
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF pump speed loop error with high speed; check for leaks that let the pump overrun.
    4. 4The pump runs fast in the control loop; check for a leak that lets pressure escape.
    5. 5A high pump speed in the control loop means the controller keeps raising the speed to hold pressure, which points at a leaking line or valve downstream of the pump.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Detroit SPN 4374 FMI 19Diesel Exhaust Fluid System is Not Being Controlled as Expected

    Detroit lists SPN 4374 FMI 19 as "Diesel Exhaust Fluid System is Not Being Controlled as Expected".· Lost message
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF system is not controlled as expected; check the level, the filter and the pump.
    4. 4The system is not controlled as expected; check the pressure sensor and the pump together.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 4375 FMI 3Diesel Exhaust Fluid Pump Circuit Failed High

    Same failure as SPN 3361 FMI 3 ("Diesel Exhaust Fluid System Circuit Failed High") on a sibling part: Detroit lists SPN 4375 FMI 3 as "Diesel Exhaust Fluid Pump Circuit Failed High".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 3361 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3361 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 4375 FMI 4Diesel Exhaust Fluid Pump Circuit Failed Low

    Same failure as SPN 3361 FMI 4 ("Diesel Exhaust Fluid System Circuit Failed Low") on a sibling part: Detroit lists SPN 4375 FMI 4 as "Diesel Exhaust Fluid Pump Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 3361 FMI 4, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3361 FMI 4, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 4375 FMI 5Diesel Exhaust Fluid Pump Circuit Failed Open

    Same failure as SPN 3361 FMI 5 ("Diesel Exhaust Fluid System Circuit Failed Open") on a sibling part: Detroit lists SPN 4375 FMI 5 as "Diesel Exhaust Fluid Pump Circuit Failed Open".· Open circuit
    Check soon

    Causes

    • The causes listed under SPN 3361 FMI 5, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3361 FMI 5, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Detroit SPN 5435 FMI 7Non Diesel Exhaust Fluid Flow Situation

    Detroit lists SPN 5435 FMI 7 as "Non Diesel Exhaust Fluid Flow Situation".· Part or controller
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3A non-DEF flow situation means fluid other than DEF is passing; check the fluid and the lines.
    4. 4Non-DEF flow: check that the fluid in the tank is DEF and the lines are not cross-connected.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 5435 FMI 11DEF Pump Blocked Loop Error

    Detroit lists SPN 5435 FMI 11 as "DEF Pump Blocked Loop Error".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF pump blocked-loop error means the pump is blocked; check for frozen fluid and crystals.
    4. 4Blocked loop: check for frozen DEF or crystals blocking the pump.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520328 FMI 7Diesel Exhaust Fluid System Has Been Over-pressurized

    Detroit lists SPN 520328 FMI 7 as "Diesel Exhaust Fluid System Has Been Over-pressurized".· Part or controller
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF system was over-pressurised; inspect the lines and the pump for damage.
    4. 4Over-pressurised: inspect the lines and pump for cracks from the pressure.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 520329 FMI 31DEF Flow Quantity Below Normal

    Detroit lists SPN 520329 FMI 31 as "DEF Flow Quantity Below Normal".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF flow is below normal; check the filter, the lines and the nozzle.
    4. 4Flow below normal: check the filter, the lines and the nozzle.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520342 FMI 17DEF System Rationality DEF Pump Speed High

    Detroit lists SPN 520342 FMI 17 as "DEF System Rationality DEF Pump Speed High".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the DEF pump
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the DEF pump in the tool and watch the result.
    3. 3The DEF pump speed is high for the delivered pressure; check for a leak.
    4. 4Pump speed high for the pressure: look for a leak in the line or the pump.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Check the DEF level and quality before testing any electrical part of the dosing unit.
  2. 2Inspect the DEF lines and the doser for crystals, kinks and leaks.
  3. 3Check the pump connector and the pump wiring for corrosion and damage.
  4. 4Run the dosing or pressure test in the diagnostic tool and watch the pump speed.

Causes

  • Frozen or crystallised DEF in the pump or lines
  • Plugged filter or doser
  • Pump failure
  • Wiring fault

Most common here: real condition (8 of 24)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: DEF warning lamps, a loss of power and a derate if not corrected.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.