Detroit · Communication
Detroit Engine-side CAN link (MCM, ACM, CPC5) fault codes
The MCM, ACM and CPC5 exchange data over CAN. Detroit logs a missing message, a bus-off, a CAN signal that is faulty and the loss of the ACM2 or CPC module.
Where to read it
Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.
What do these codes mean?
Detroit codes SPN 84 FMI 0 to SPN 2000 FMI 9 are all about the engine-side CAN link (MCM, ACM, CPC5). The most common failure type is lost message (9 of 21); 3 need an immediate stop. Start with this check: check the CAN wiring and the terminating resistance on the data link.
How urgent are they?
3 of 21 codes here mean stop now; the other 18 can wait until the shift ends, but find the cause before the next one.
- Stop now3
- Check soon18
What should I check first?
Check the CAN wiring and the terminating resistance on the data link.
Shared checks21 of 21
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Detroit SPN 84 FMI 0Vehicle Speed Above Programmable Threshold 1 While Driving
Detroit lists SPN 84 FMI 0 as "Vehicle Speed Above Programmable Threshold 1 While Driving". The MCM logged a communication or data problem with the module named in the title. Vehicle speed reaches the engine controller from the transmission output sensor and from the ABS over the vehicle CAN, so speed-limit and anti-tamper checks compare two independent sources.· Real conditionReal conditionCheck soonCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3Ask the driver whether the truck was driven above the programmed road speed limit, and read the limit set in the CPC5 parameters.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 84 FMI 6VSS Anti-Tamper Detection via ABS Vehicle Speed Comparison
Detroit lists SPN 84 FMI 6 as "VSS Anti-Tamper Detection via ABS Vehicle Speed Comparison". The MCM logged a communication or data problem with the module named in the title. Vehicle speed reaches the engine controller from the transmission output sensor and from the ABS over the vehicle CAN, so speed-limit and anti-tamper checks compare two independent sources.· Shorted lowShorted lowCheck soonCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3Compare the speed from the transmission sensor with the ABS wheel speed; a mismatch suggests a wrong tire or axle parameter or a tampered sensor.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 84 FMI 11Vehicle Speed Above Programmable Threshold 2 While Driving
Same failure as SPN 84 FMI 0 ("Vehicle Speed Above Programmable Threshold 1 While Driving") on a sibling part: Detroit lists SPN 84 FMI 11 as "Vehicle Speed Above Programmable Threshold 2 While Driving". Vehicle speed reaches the engine controller from the transmission output sensor and from the ABS over the vehicle CAN, so speed-limit and anti-tamper checks compare two independent sources.· Lost messageLost messageCheck soonCauses
- The causes listed under SPN 84 FMI 0, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 84 FMI 0, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 84 FMI 13Vehicle Speed Over PTCAN Not Available
Same failure as SPN 1231 FMI 9 ("ACM Message Not Received or has Stopped Arriving") on a sibling part: Detroit lists SPN 84 FMI 13 as "Vehicle Speed Over PTCAN Not Available". Vehicle speed reaches the engine controller from the transmission output sensor and from the ABS over the vehicle CAN, so speed-limit and anti-tamper checks compare two independent sources.· Part or controllerPart or controllerCheck soonCauses
- The causes listed under SPN 1231 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1231 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 84 FMI 19Vehicle Speed Value Outside Allowable Range
Detroit lists SPN 84 FMI 19 as "Vehicle Speed Value Outside Allowable Range". The MCM stopped receiving the message it expects from the module named in the title. Vehicle speed reaches the engine controller from the transmission output sensor and from the ABS over the vehicle CAN, so speed-limit and anti-tamper checks compare two independent sources.· Lost messageLost messageCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Check that the tire size and axle ratio parameters match the truck, because a wrong value pushes the calculated speed out of range.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 84 FMI 20Vehicle Speed Failure
Detroit lists SPN 84 FMI 20 as "Vehicle Speed Failure". The MCM logged a communication or data problem with the module named in the title. Vehicle speed reaches the engine controller from the transmission output sensor and from the ABS over the vehicle CAN, so speed-limit and anti-tamper checks compare two independent sources.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3Watch the speed signal on a road test and compare it with the dash and a GPS speed to see where it drops out.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 84 FMI 21Vehicle Speed Failure
Same failure as SPN 84 FMI 20 ("Vehicle Speed Failure") on a sibling part: Detroit lists SPN 84 FMI 21 as "Vehicle Speed Failure". Vehicle speed reaches the engine controller from the transmission output sensor and from the ABS over the vehicle CAN, so speed-limit and anti-tamper checks compare two independent sources.· Erratic or implausibleErratic or implausibleCheck soonCauses
- The causes listed under SPN 84 FMI 20, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 84 FMI 20, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 190 FMI 9Engine Speed Signal not Available via Controller Area Network (CAN)
Same failure as SPN 1231 FMI 9 ("ACM Message Not Received or has Stopped Arriving") on a sibling part: Detroit lists SPN 190 FMI 9 as "Engine Speed Signal not Available via Controller Area Network (CAN)". Engine speed comes from the crankshaft and camshaft sensors and is shared with other modules over CAN; overspeed faults protect the engine from over-revving.· Lost messageLost messageCheck soonCauses
- The causes listed under SPN 1231 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1231 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 190 FMI 14Engine Overspeed while Driving
Detroit lists SPN 190 FMI 14 as "Engine Overspeed while Driving". The MCM stopped receiving the message it expects from the module named in the title. Engine speed comes from the crankshaft and camshaft sensors and is shared with other modules over CAN; overspeed faults protect the engine from over-revving.· Lost messageLost messageStop nowCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Ask whether the engine was over-revved on a downshift and read the freeze-frame engine speed; inspect the drivetrain if it happened.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 190 FMI 15Engine Overspeed Pre-Warning
Detroit lists SPN 190 FMI 15 as "Engine Overspeed Pre-Warning". The MCM logged a communication or data problem with the module named in the title. Engine speed comes from the crankshaft and camshaft sensors and is shared with other modules over CAN; overspeed faults protect the engine from over-revving.· Real conditionReal conditionStop nowCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3This is the warning before the shutdown; check the retarder use and the gear the truck was in when the speed climbed.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 190 FMI 16Engine Overspeed while Stationary
Detroit lists SPN 190 FMI 16 as "Engine Overspeed while Stationary". The MCM logged a communication or data problem with the module named in the title. Engine speed comes from the crankshaft and camshaft sensors and is shared with other modules over CAN; overspeed faults protect the engine from over-revving.· Real conditionReal conditionStop nowCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3An overspeed with the vehicle stopped points to a governor, pedal or fuel-supply problem such as runaway oil or a stuck injector.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 625 FMI 2Invalid Data on Engine CAN Link
Detroit lists SPN 625 FMI 2 as "Invalid Data on Engine CAN Link". The MCM stopped receiving the message it expects from the module named in the title. The MCM, ACM and CPC5 each send diagnostic message DM1 on the powertrain CAN; a missing DM1 means that controller is silent.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Read the content of the engine CAN message with the tool and look for values that do not change or are out of range.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 625 FMI 8MCM PT-CAN DM1 Message Not Received or has Stopped Arriving
Same failure as SPN 1231 FMI 9 ("ACM Message Not Received or has Stopped Arriving") on a sibling part: Detroit lists SPN 625 FMI 8 as "MCM PT-CAN DM1 Message Not Received or has Stopped Arriving". The MCM, ACM and CPC5 each send diagnostic message DM1 on the powertrain CAN; a missing DM1 means that controller is silent.· Erratic or implausibleErratic or implausibleCheck soonCauses
- The causes listed under SPN 1231 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1231 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 625 FMI 9ACM PT-CAN DM1 Message Not Received or has Stopped Arriving
Same failure as SPN 1231 FMI 9 ("ACM Message Not Received or has Stopped Arriving") on a sibling part: Detroit lists SPN 625 FMI 9 as "ACM PT-CAN DM1 Message Not Received or has Stopped Arriving". The MCM, ACM and CPC5 each send diagnostic message DM1 on the powertrain CAN; a missing DM1 means that controller is silent.· Lost messageLost messageCheck soonCauses
- The causes listed under SPN 1231 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1231 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 625 FMI 17No ACM2 Communication - Pre-Warning
Detroit lists SPN 625 FMI 17 as "No ACM2 Communication - Pre-Warning". The MCM logged a communication or data problem with the module named in the title. The MCM, ACM and CPC5 each send diagnostic message DM1 on the powertrain CAN; a missing DM1 means that controller is silent.· Real conditionReal conditionCheck soonCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3This is the warning stage of an ACM2 communication loss; check the ACM2 power, ground and CAN wiring before it escalates.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 625 FMI 18No ACM2 Communication - Warning
Detroit lists SPN 625 FMI 18 as "No ACM2 Communication - Warning". The MCM logged a communication or data problem with the module named in the title. The MCM, ACM and CPC5 each send diagnostic message DM1 on the powertrain CAN; a missing DM1 means that controller is silent.· Real conditionReal conditionCheck soonCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3This is the warning stage after the pre-warning; check the ACM2 module and its power, because the aftertreatment can no longer be managed.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 639 FMI 14J1939 Data Link Failure
Detroit lists SPN 639 FMI 14 as "J1939 Data Link Failure". The MCM stopped receiving the message it expects from the module named in the title. The J1939 data link carries data between all modules; a failure here usually involves the data link wiring or a module that is pulling the bus down.· Lost messageLost messageCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Check the J1939 data link for a module that pulls the bus down by unplugging modules one at a time.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 1231 FMI 9ACM Message Not Received or has Stopped Arriving
A controller stopped receiving the CAN message from the ACM (or the MCM CAN1 signal in some lists). Detroit logs this when the module is not powered, is resetting or the CAN link is damaged.· Lost messageLost messageCheck soonCauses
- ACM without power, ground or ignition feed
- CAN wiring open or chafed between the MCM and the ACM
- Terminating resistor or connector fault on the data link
- ACM or MCM software mismatch or reset
Checks
- 1Check the ACM fuse, power and ground, and the ignition feed with the key on.
- 2Measure the CAN link resistance at the diagnostic socket and compare it with the expected value for a healthy bus.
- 3Inspect the ACM and MCM connectors for bent pins and moisture.
- 4Read whether the ACM also stores a code for the missing message.
- 5Update the software on the modules if the versions do not match.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 1231 FMI 14Powertrain-CAN Short to Battery - Bus off
Detroit lists SPN 1231 FMI 14 as "Powertrain-CAN Short to Battery - Bus off". The MCM stopped receiving the message it expects from the module named in the title. The ACM and the MCM exchange data on CAN1; a missing message can be caused by a controller that is resetting or by damaged bus wiring.· Shorted highShorted highCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3A bus-off to battery means a CAN wire is shorted to battery voltage; check the powertrain CAN wires for contact with a power wire.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 1669 FMI 9Aftertreatment Control Module CAN 4 Signal Missing
Same failure as SPN 1231 FMI 9 ("ACM Message Not Received or has Stopped Arriving") on a sibling part: Detroit lists SPN 1669 FMI 9 as "Aftertreatment Control Module CAN 4 Signal Missing". The ACM receives data on CAN4 from sensors in the aftertreatment system; a missing signal means those sensors are not reporting.· Lost messageLost messageCheck soonCauses
- The causes listed under SPN 1231 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1231 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 2000 FMI 9Lost Communication with a CPC Module
Same failure as SPN 1231 FMI 9 ("ACM Message Not Received or has Stopped Arriving") on a sibling part: Detroit lists SPN 2000 FMI 9 as "Lost Communication with a CPC Module". The CPC module is the vehicle powertrain controller; another module logs this when it can no longer see it on the network.· Lost messageLost messageCheck soonCauses
- The causes listed under SPN 1231 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1231 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Check the CAN wiring and the terminating resistance on the data link.
- 2Check the power and ground of the module that is not reporting.
- 3Read which module the code names and test that module first.
- 4Update or match the software versions in the tool.
Causes
- CAN wiring damage, a terminating resistor fault or a connector problem
- Low battery voltage or a controller that resets
- A module that has lost power or failed
- Software mismatch among modules
Most common here: lost message (9 of 21)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Several lamps at once, a derate or no start, and often codes from more than one module.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Detroit Diesel DD15 Gen 5 (2023) Fault Codes List, Diesel Repair (SPN/FMI with Detroit descriptions)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.