Detroit · Communication
Detroit Module data timeouts and plausibility fault codes
These codes say that data from another control unit (TCM, ICUC, VRDU, IPPC, ABS or the ACM data set) is missing, late or not believable. The wiring may be fine and the fault may sit in the other module.
Where to read it
Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.
What do these codes mean?
Detroit codes SPN 513 FMI 9 to SPN 521004 FMI 14 are all about the module data timeouts and plausibility. The most common failure type is part or controller (8 of 18); none needs an immediate stop. Start with this check: read which module the code names and check whether that module also has stored faults.
How urgent are they?
None of the 18 codes here means stop now; all 18 can wait until the shift ends, but find the cause before the next one.
- Check soon18
What should I check first?
Read which module the code names and check whether that module also has stored faults.
Shared checks18 of 18
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Detroit SPN 513 FMI 9Actual Torque Signal Not Available via CAN
Detroit lists SPN 513 FMI 9 as "Actual Torque Signal Not Available via CAN". The MCM stopped receiving the message it expects from the module named in the title. Actual engine torque is sent to the transmission controller on the CAN; a missing signal can stop smooth shifting.· Lost messageLost messageCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Check the engine torque message on the CAN with the transmission connected and see whether the MCM transmits it.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 523 FMI 13J1939 Transmission Current Gear Signal is Missing
Detroit lists SPN 523 FMI 13 as "J1939 Transmission Current Gear Signal is Missing". The MCM logged a communication or data problem with the module named in the title. The current gear is sent by the transmission controller on J1939 and the engine uses it for torque limiting and cruise.· Part or controllerPart or controllerCheck soonCauses
- Software mismatch among modules
- Wiring or connector fault on the data link
Checks
- 1Compare the software versions of the modules.
- 2Check the data link wiring for chafing and corrosion.
- 3Check the transmission controller power and the J1939 wiring, since the engine is not receiving the current gear message.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 523 FMI 19J1939 Transmission Current Gear Signal is Erratic
Detroit lists SPN 523 FMI 19 as "J1939 Transmission Current Gear Signal is Erratic". The MCM stopped receiving the message it expects from the module named in the title. The current gear is sent by the transmission controller on J1939 and the engine uses it for torque limiting and cruise.· Lost messageLost messageCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Read the gear signal while shifting; an erratic value suggests a noisy bus or a transmission controller fault.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 1243 FMI 12ABS Data Not Plausible
Detroit lists SPN 1243 FMI 12 as "ABS Data Not Plausible". The MCM stopped receiving the message it expects from the module named in the title. ABS data reaches the engine on the vehicle CAN; implausible or missing data limits cruise and automatic shifting.· Part or controllerPart or controllerCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Compare the ABS data in the tool with the wheel speeds and check the ABS controller for its own codes.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 1243 FMI 14ABS Faults Restricts Automatic Gear Selection Functionality
Detroit lists SPN 1243 FMI 14 as "ABS Faults Restricts Automatic Gear Selection Functionality". The MCM stopped receiving the message it expects from the module named in the title. ABS data reaches the engine on the vehicle CAN; implausible or missing data limits cruise and automatic shifting.· Lost messageLost messageCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Fix the ABS faults first, because the transmission restricts automatic gear selection until the ABS is healthy.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 1482 FMI 12TCM Data not Plausible
Same failure as SPN 1243 FMI 12 ("ABS Data Not Plausible") on a sibling part: Detroit lists SPN 1482 FMI 12 as "TCM Data not Plausible". The TCM is the transmission controller; the engine listens for its J1939 messages to know the gear and torque request.· Part or controllerPart or controllerCheck soonCauses
- The causes listed under SPN 1243 FMI 12, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1243 FMI 12, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 1482 FMI 14TCM Not Transmitting on J1939 or Malfunctioning
Detroit lists SPN 1482 FMI 14 as "TCM Not Transmitting on J1939 or Malfunctioning". The MCM stopped receiving the message it expects from the module named in the title. The TCM is the transmission controller; the engine listens for its J1939 messages to know the gear and torque request.· OtherOtherCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3Check that the transmission controller is powered, transmitting on J1939 and not stuck in a fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Detroit SPN 1483 FMI 2MCM Data not Plausible
Same failure as SPN 1243 FMI 12 ("ABS Data Not Plausible") on a sibling part: Detroit lists SPN 1483 FMI 2 as "MCM Data not Plausible". The MCM sends data to the other controllers; the receiving module logs this when it cannot trust or no longer sees the MCM data.· Erratic or implausibleErratic or implausibleCheck soonCauses
- The causes listed under SPN 1243 FMI 12, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1243 FMI 12, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 1483 FMI 12MCM data - CAN timeout
Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 1483 FMI 12 as "MCM data - CAN timeout". The MCM sends data to the other controllers; the receiving module logs this when it cannot trust or no longer sees the MCM data.· Part or controllerPart or controllerCheck soonCauses
- The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 1590 FMI 12VRDU Data - CAN Timeout
Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 1590 FMI 12 as "VRDU Data - CAN Timeout". The VRDU is the vehicle radar and distance unit used for adaptive cruise; its data is read by the engine controller over CAN.· Part or controllerPart or controllerCheck soonCauses
- The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 3236 FMI 9Exhaust Mass Signal Not Available via CAN
Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 3236 FMI 9 as "Exhaust Mass Signal Not Available via CAN". Exhaust mass flow is sent over CAN and is needed to calculate the DEF dose; without it the dosing falls back to a safe mode.· Lost messageLost messageCheck soonCauses
- The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 3613 FMI 12ICUC Data - CAN Timeout
Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 3613 FMI 12 as "ICUC Data - CAN Timeout". The ICUC is the instrument cluster controller; engine data it shows (gauges and lamps) depends on its CAN messages.· Part or controllerPart or controllerCheck soonCauses
- The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 4206 FMI 2J1939 TSC1 Message Counter Failure
Detroit lists SPN 4206 FMI 2 as "J1939 TSC1 Message Counter Failure". The MCM stopped receiving the message it expects from the module named in the title. The TSC1 torque request message from another controller carries a counter that the engine checks for sequence errors.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3The TSC1 torque message counter is wrong; check which module sends the torque request and the bus quality.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 4207 FMI 2J1939 TSC1 Checksum Failure
Detroit lists SPN 4207 FMI 2 as "J1939 TSC1 Checksum Failure". The MCM stopped receiving the message it expects from the module named in the title. The TSC1 message also carries a checksum so the engine can reject corrupted torque requests.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3The TSC1 checksum failed; check the sender module and the bus for noise.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Detroit SPN 520222 FMI 12ACM Data not Plausible
Same failure as SPN 1243 FMI 12 ("ABS Data Not Plausible") on a sibling part: Detroit lists SPN 520222 FMI 12 as "ACM Data not Plausible". The ACM data seen by another controller is not plausible, so that controller discards it.· Part or controllerPart or controllerCheck soonCauses
- The causes listed under SPN 1243 FMI 12, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 1243 FMI 12, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 520230 FMI 12IPPC Data - CAN Timeout
Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 520230 FMI 12 as "IPPC Data - CAN Timeout". The IPPC (predictive cruise) data message timed out on the CAN.· Part or controllerPart or controllerCheck soonCauses
- The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Detroit SPN 520232 FMI 9NOx Mass Signal Not Available via Controller Area Network
Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 520232 FMI 9 as "NOx Mass Signal Not Available via Controller Area Network". The NOx mass signal normally arrives over CAN from the ACM; without it the engine cannot report NOx mass.· Lost messageLost messageCheck soonCauses
- The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Detroit SPN 521004 FMI 14Automatic Gear Selection - Incompatible or Missing Dataset
Detroit lists SPN 521004 FMI 14 as "Automatic Gear Selection - Incompatible or Missing Dataset". The MCM stopped receiving the message it expects from the module named in the title. Automatic gear selection needs a matching data set; an incompatible or missing one disables it.· OtherOtherCheck soonCauses
- Power or ground missing at that module
- CAN wiring fault between the modules
Checks
- 1Check the power and ground feeds of the module that is not reporting.
- 2Check the CAN wiring and terminating resistance.
- 3The gear selection data set is missing or incompatible; load the right data set.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Read which module the code names and check whether that module also has stored faults.
- 2Check the power and ground feeds of the module that stopped reporting.
- 3Compare the software versions of the modules in the diagnostic tool.
- 4Look at the CAN wiring to that module for chafing and corrosion.
Causes
- The other module has lost power, reset or failed
- Software or parameter mismatch between the modules
- CAN wiring chafed or a connector corroded
- A message counter or checksum error caused by a noisy link
Most common here: part or controller (8 of 18)
Check power and ground at the module connector with the key on, then its fuses.
When to stop
You'll notice: Gear selection, cruise, dash lamps or the aftertreatment may misbehave, and the check-engine lamp comes on.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Detroit Diesel DD15 Gen 5 (2023) Fault Codes List, Diesel Repair (SPN/FMI with Detroit descriptions)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.