EF Logo

Cummins · Engine control module

Cummins Sensor supply circuits and ECM internal faults fault codes

The ECM provides separate 5 V reference supplies to groups of sensors. These codes cover the ECM's own hardware, calibration memory and checksum checks.

More about these parts

A memory card in the ECM stores datalogger information. The ECM keeps a real-time clock for time stamps on fault codes and some maintenance functions.

FaultStop111Cummins · Engine control module
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 111 to 8196 are all about the sensor supply circuits and ECM internal faults. The most common failure type is shorted high (6 of 24); 1 needs an immediate stop. Start with this check: note which sensors share the failed supply and which codes set together.

How urgent are they?

1 of 24 codes here means stop now; 20 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Stop now1
  • Check soon20
  • Info3

What should I check first?

Note which sensors share the failed supply and which codes set together

Shared checks

24 of 24

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Engine control module3 codes

    • Cummins 111Engine control module: Critical internal failure

      The engine control module has detected a critical failure inside itself.· Other
      Stop now

      Causes

      • Internal ECM failure
      • Power or ground supply to the ECM unstable
      • Water or corrosion in the ECM connectors
      • Wrong or corrupt calibration

      Checks

      1. 1Read the code with INSITE and note whether it is active or only stored
      2. 2Check the ECM power, ground and battery supply for steady voltage
      3. 3Inspect the ECM connectors and the harness near the ECM for water and corrosion
      4. 4Check that the calibration is correct and current
      5. 5Replace the ECM only after supply and harness checks pass
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 343Engine control module: Warning internal hardware failure

      The ECM has found a non-critical internal hardware fault.· Other
      Check soon

      Causes

      • Early ECM internal fault
      • Marginal battery or ground supply
      • Water in the ECM connector

      Checks

      1. 1Read all ECM codes and see whether 343 appears with other ECM codes
      2. 2Check battery and ground voltage at the ECM under load
      3. 3Inspect the ECM connectors for water and corrosion
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 6155Engine control module: Root cause not known

      The ECM logged a fault on the engine control module but could not narrow down the cause.· Other
      Info

      Causes

      • A related circuit or sensor fault that has not been read yet
      • Intermittent connection that did not repeat during the test
      • Real operating problem that the strategy could not classify

      Checks

      1. 1Read every code on the engine and work the more specific ones first
      2. 2Check the engine control module wiring and connectors for damage and corrosion
      3. 3Review the freeze-frame data, if stored, for the operating conditions when the code set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Sensor supply 2 circuit2 codes

    • Cummins 187Sensor supply 2 circuit: Voltage low / shorted low

      Same failure as 352 on the sensor supply 2 circuit: the same fault condition as 352, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 352, applied to the sensor supply 2 circuit
      • Wiring or connector problem local to the sensor supply 2 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 352, starting at the sensor supply 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Sensor supply 2 circuit - voltage low (shorted to a low source)

    • Cummins 227Sensor supply 2 circuit: Voltage high / shorted high

      Same failure as 386 on the sensor supply 2 circuit: the same fault condition as 386, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 386, applied to the sensor supply 2 circuit
      • Wiring or connector problem local to the sensor supply 2 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 386, starting at the sensor supply 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Sensor supply 2 circuit - voltage high (shorted to a high source)

  • Sensor supply 3 circuit2 codes

    • Cummins 238Sensor supply 3 circuit: Voltage low / shorted low

      Same failure as 352 on the sensor supply 3 circuit: the same fault condition as 352, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 352, applied to the sensor supply 3 circuit
      • Wiring or connector problem local to the sensor supply 3 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 352, starting at the sensor supply 3 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Sensor supply 3 circuit - voltage low (shorted to a low source)

    • Cummins 239Sensor supply 3 circuit: Voltage high / shorted high

      Same failure as 386 on the sensor supply 3 circuit: the same fault condition as 386, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 386, applied to the sensor supply 3 circuit
      • Wiring or connector problem local to the sensor supply 3 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 386, starting at the sensor supply 3 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Sensor supply 3 circuit - voltage high (shorted to a high source)

  • Real-time clock power interrupt1 code

    • Cummins 319Real-time clock power interrupt: Erratic reading

      The ECM judges the real-time clock power interrupt to be erratic or implausible: the value jumps, drifts or disagrees with related readings, which suggests a poor connection or a part on its way out.· Erratic or implausible
      Check soon

      Causes

      • Intermittent connector or wiring contact on the real-time clock power interrupt
      • Part ageing or failing and giving unstable output
      • Electrical noise from a poorly routed wire or a bad ground

      Checks

      1. 1Watch the real-time clock power interrupt live in INSITE and wiggle the harness and connector to catch dropouts
      2. 2Compare the real-time clock power interrupt with a related reading to decide which one is wrong
      3. 3Check the connector for moisture and corrosion and the ground connection for tightness
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Real-time clock power interrupt - data erratic or incorrect

  • Engine control module calibration memory software1 code

    • Cummins 346Engine control module calibration memory software: Bad device or component

      The ECM flags the engine control module calibration memory software as a bad device or component after a self-test or a response check failed.· Part or controller
      Check soon

      Causes

      • Failed engine control module calibration memory software or its internal electronics
      • Supply or ground fault that made the self-test fail
      • Connector or harness damage that stops the part from communicating

      Checks

      1. 1Check supply voltage and ground at the engine control module calibration memory software before replacing it
      2. 2Inspect the engine control module calibration memory software connector and wiring for water, corrosion and damage
      3. 3Read the engine control module calibration memory software for any stored status or self-test result with the service tool
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Sensor supply 1 circuit2 codes

    • Cummins 352Sensor supply 1 circuit: Voltage low / shorted low

      The ECM reads the sensor supply 1 circuit below its allowed voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire to the sensor supply 1 circuit rubbed through and shorted to ground or to the engine block
      • Open 5 V reference or open signal wire that lets the input drop to zero
      • Corroded or backed-out pin in the sensor supply 1 circuit connector

      Checks

      1. 1Key on, unplug the sensor supply 1 circuit and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
      2. 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
      3. 3Measure resistance from the sensor supply 1 circuit signal wire to ground with the ECM unplugged to find a short
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Sensor supply 1 circuit - voltage low (shorted to a low source)

    • Cummins 386Sensor supply 1 circuit: Voltage high / shorted high

      The ECM reads the sensor supply 1 circuit above its allowed voltage band.· Shorted high
      Check soon

      Causes

      • Short to a 5 V reference or a battery wire in the harness to the sensor supply 1 circuit
      • Open or high-resistance return wire that lets the signal float high
      • Water or corrosion in the connector bridging two pins together

      Checks

      1. 1Key on, unplug the sensor supply 1 circuit and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
      2. 2Jumper the signal wire of the sensor supply 1 circuit to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
      3. 3Check continuity and resistance of the return wire from the sensor supply 1 circuit back to the ECM
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Sensor supply 1 circuit - voltage high (shorted to a high source)

  • Sensor supply 6 circuit2 codes

    • Cummins 515Sensor supply 6 circuit: Voltage high / shorted high

      Same failure as 386 on the sensor supply 6 circuit: the same fault condition as 386, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 386, applied to the sensor supply 6 circuit
      • Wiring or connector problem local to the sensor supply 6 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 386, starting at the sensor supply 6 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Sensor supply 6 circuit - voltage high (shorted to a high source)

    • Cummins 516Sensor supply 6 circuit: Voltage low / shorted low

      Same failure as 352 on the sensor supply 6 circuit: the same fault condition as 352, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 352, applied to the sensor supply 6 circuit
      • Wiring or connector problem local to the sensor supply 6 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 352, starting at the sensor supply 6 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Sensor supply 6 circuit - voltage low (shorted to a low source)

  • Sensor supply 52 codes

    • Cummins 1695Sensor supply 5: Voltage high / shorted high

      Same failure as 386 on the sensor supply 5: the same fault condition as 386, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 386, applied to the sensor supply 5
      • Wiring or connector problem local to the sensor supply 5

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 386, starting at the sensor supply 5 and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Sensor supply 5 - voltage high (shorted to a high source)

    • Cummins 1696Sensor supply 5: Voltage low / shorted low

      Same failure as 352 on the sensor supply 5: the same fault condition as 352, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 352, applied to the sensor supply 5
      • Wiring or connector problem local to the sensor supply 5

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 352, starting at the sensor supply 5 and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Sensor supply 5 - voltage low (shorted to a low source)

  • Sensor supply 4 circuit2 codes

    • Cummins 2185Sensor supply 4 circuit: Voltage high / shorted high

      Same failure as 386 on the sensor supply 4 circuit: the same fault condition as 386, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 386, applied to the sensor supply 4 circuit
      • Wiring or connector problem local to the sensor supply 4 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 386, starting at the sensor supply 4 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Sensor supply 4 circuit - voltage high (shorted to a high source)

    • Cummins 2186Sensor supply 4 circuit: Voltage low / shorted low

      Same failure as 352 on the sensor supply 4 circuit: the same fault condition as 352, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 352, applied to the sensor supply 4 circuit
      • Wiring or connector problem local to the sensor supply 4 circuit

      Checks

      1. 1Unplug the sensors on this supply one at a time and see which one restores the voltage.
      2. 2Work through the checks listed for 352, starting at the sensor supply 4 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Sensor supply 4 circuit - voltage low (shorted to a low source)

  • Engine control module calibration memory checksum1 code

    • Cummins 2416Engine control module calibration memory checksum: Out of calibration

      The ECM reports the engine control module calibration memory checksum as out of calibration: the value or setting it received does not match what the ECM was programmed to expect.· Part or controller
      Check soon

      Causes

      • Parameter set for a feature that is not fitted on this vehicle
      • Wrong or outdated calibration in the ECM
      • Source module sending an invalid or unscaled value for the engine control module calibration memory checksum

      Checks

      1. 1Compare the ECM parameters with the vehicle equipment, especially those that enable the engine control module calibration memory checksum
      2. 2Reflash the ECM with the correct calibration if the software level does not match
      3. 3Read the source module for its own codes and check its configuration
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Real-time clock2 codes

    • Cummins 3492Real-time clock: Abnormal rate of change

      The real-time clock changed faster than it physically could, so the ECM treats the reading as a sensor or wiring problem and not as a real change.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the harness or connector of the real-time clock
      • Failing part giving unstable output
      • Poor ground or noisy supply feeding the circuit

      Checks

      1. 1Log the real-time clock while moving the harness and connector, and look for steps instead of smooth changes
      2. 2Inspect the real-time clock connector for water, corrosion and loose pins
      3. 3Check the supply and ground at the real-time clock while the engine runs
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 3656Real-time clock: Out of calibration

      Same failure as 2416 on the real-time clock: the same fault condition as 2416, reported for this part.· Part or controller
      Check soon

      Causes

      • Same causes as 2416, applied to the real-time clock
      • Wiring or connector problem local to the real-time clock

      Checks

      1. 1Check the ECM backup supply and the battery disconnect history.
      2. 2Work through the checks listed for 2416, starting at the real-time clock and its connector
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Engine control module calibration memory1 code

    • Cummins 3697Engine control module calibration memory: Bad device or component

      Same failure as 346 on the engine control module calibration memory: the same fault condition as 346, reported for this part.· Lost message
      Check soon

      Causes

      • Same causes as 346, applied to the engine control module calibration memory
      • Wiring or connector problem local to the engine control module calibration memory

      Checks

      1. 1Reflash the calibration with INSITE and check the ECM supply during the flash.
      2. 2Work through the checks listed for 346, starting at the engine control module calibration memory and its connector
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine control module calibration memory (rom) corruption1 code

    • Cummins 5874Engine control module calibration memory (rom) corruption: Root cause not known

      Same failure as 6155 on the engine control module calibration memory corruption: the same fault condition as 6155, reported for this part.· Part or controller
      Info

      Causes

      • Same causes as 6155, applied to the engine control module calibration memory corruption
      • Wiring or connector problem local to the engine control module calibration memory corruption

      Checks

      1. 1Run a cylinder cutout or power balance test in INSITE to confirm which cylinder is weak.
      2. 2Work through the checks listed for 6155, starting at the engine control module calibration memory corruption and its connector
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Datalog memory card2 codes

    • Cummins 8195Datalog memory card: Bad device or component

      Same failure as 346 on the datalog memory card: the same fault condition as 346, reported for this part.· Part or controller
      Check soon

      Causes

      • Same causes as 346, applied to the datalog memory card
      • Wiring or connector problem local to the datalog memory card

      Checks

      1. 1Remove and reseat the card, or replace it if it is damaged.
      2. 2Work through the checks listed for 346, starting at the datalog memory card and its connector
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 8196Datalog memory card: Root cause not known

      Same failure as 6155 on the datalog memory card: the same fault condition as 6155, reported for this part.· Part or controller
      Info

      Causes

      • Same causes as 6155, applied to the datalog memory card
      • Wiring or connector problem local to the datalog memory card

      Checks

      1. 1Run a cylinder cutout or power balance test in INSITE to confirm which cylinder is weak.
      2. 2Work through the checks listed for 6155, starting at the datalog memory card and its connector
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

Shared checks

Checks, in order

  1. 1Note which sensors share the failed supply and which codes set together
  2. 2Check the ECM power and ground connections and battery voltage
  3. 3Reseat the memory card and check that its slot is clean and undamaged
  4. 4Check the ECM power supply and look for power interruptions in the history
  5. 5Unplug the sensors on that supply one at a time and watch the voltage recover
  6. 6Reflash the calibration with the correct file and check it completes
  7. 7Try a different known-good card of the supported type

Causes

  • Short to ground or battery in a sensor harness
  • Corrupt calibration or interrupted reflash
  • Card removed or failed
  • Clock battery or power interruption

Most common here: shorted high (6 of 24)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: Several sensor codes at once (pressure, position, temperature) and often a derate.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.