EF Logo

Cummins · Data link

Cummins Route parameter manager, GPS antenna and hybrid status fault codes

The route parameter manager (a navigation control module) supplies map and route data for predictive features, and it uses a GPS antenna to know where the vehicle is. The ECM flags an open or shorted antenna circuit, missing input, and module problems with its supply, software, USB, map loading, CAN links and hardware self-tests.

More about these parts

On hybrid applications the engine ECM receives hybrid system OBD status messages from the hybrid controller.

FaultCheck5684Cummins · Hybrid system OBD related DTC status
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 5684 to 6764 are all about the route parameter manager, GPS antenna and hybrid status. The most common failure type is lost message (3 of 21); none needs an immediate stop. Start with this check: check the GPS antenna cable and connector for damage and corrosion, and measure its circuit for opens and shorts.

How urgent are they?

None of the 21 codes here means stop now; 10 can wait until the shift ends, but find the cause before the next one; 11 are information only.

  • Check soon10
  • Info11

What should I check first?

Check the GPS antenna cable and connector for damage and corrosion, and measure its circuit for opens and shorts

Shared checks

21 of 21

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

    • Cummins 5684Hybrid system OBD related DTC status: Abnormal update rate

      The ECM is not receiving fresh data for the hybrid system OBD related DTC status at the expected rate.· Lost message
      Check soon

      Causes

      • Data link wiring fault or a poor connector contact
      • The module that sends the message for the hybrid system OBD related DTC status is offline or failing
      • Power or ground problem at the sending module

      Checks

      1. 1Look for other modules reporting timeouts to find where the link is broken
      2. 2Check the data link wiring, connectors and both terminators near the hybrid system OBD related DTC status source
      3. 3Read the module that sends the hybrid system OBD related DTC status for its own codes and for power or ground faults
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Cummins 5685Hybrid system OBD related DTC status: Condition exists

      The ECM has flagged a condition on the hybrid system OBD related DTC status.· Other
      Info

      Causes

      • The underlying system problem that the ECM is reporting on the hybrid system OBD related DTC status
      • A related sensor or circuit fault that triggered this condition
      • Operating conditions outside what the strategy expects

      Checks

      1. 1Read all active and inactive codes and work the circuit or sensor codes for the hybrid system OBD related DTC status first
      2. 2Check the live data around the hybrid system OBD related DTC status while reproducing the operating condition
      3. 3Inspect the system the hybrid system OBD related DTC status belongs to for leaks, blockage or damage
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 5691Hybrid system OBD related DTC status: Root cause not known

      The ECM logged a fault on the hybrid system OBD related DTC status but could not narrow down the cause.· Other
      Info

      Causes

      • A related circuit or sensor fault that has not been read yet
      • Intermittent connection that did not repeat during the test
      • Real operating problem that the strategy could not classify

      Checks

      1. 1Read every code on the engine and work the more specific ones first
      2. 2Check the hybrid system OBD related DTC status wiring and connectors for damage and corrosion
      3. 3Review the freeze-frame data, if stored, for the operating conditions when the code set
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Cummins 6315Hybrid system OBD related DTC status- root cause not known: Root cause not known

      Same failure as 5691 on the hybrid system OBD related DTC status- root cause not known: the same fault condition as 5691, reported for this part.· Other
      Info

      Causes

      • Same causes as 5691, applied to the hybrid system OBD related DTC status- root cause not known
      • Wiring or connector problem local to the hybrid system OBD related DTC status- root cause not known

      Checks

      1. 1Run a cylinder cutout or power balance test in INSITE to confirm which cylinder is weak.
      2. 2Work through the checks listed for 5691, starting at the hybrid system OBD related DTC status- root cause not known and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Route parameter manager module software malfunction1 code

    • Cummins 6737Route parameter manager module software malfunction: Bad device or component

      Same failure as 6745 on the route parameter manager module software malfunction: the same fault condition as 6745, reported for this part.· Part or controller
      Check soon

      Causes

      • Same causes as 6745, applied to the route parameter manager module software malfunction
      • Wiring or connector problem local to the route parameter manager module software malfunction

      Checks

      1. 1Reflash the manager with the current software.
      2. 2Work through the checks listed for 6745, starting at the route parameter manager module software malfunction and its connector
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Route parameter manager module3 codes

    • Cummins 6738Route parameter manager module: Voltage high / shorted high

      The ECM reads the route parameter manager module above its allowed voltage band.· Shorted high
      Check soon

      Causes

      • Short to a 5 V reference or a battery wire in the harness to the route parameter manager module
      • Open or high-resistance return wire that lets the signal float high
      • Water or corrosion in the connector bridging two pins together

      Checks

      1. 1Key on, unplug the route parameter manager module and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
      2. 2Jumper the signal wire of the route parameter manager module to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
      3. 3Check continuity and resistance of the return wire from the route parameter manager module back to the ECM
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Route parameter manager module - voltage high (shorted to a high source)

    • Cummins 6739Route parameter manager module: Voltage low / shorted low

      The ECM reads the route parameter manager module below its allowed voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire to the route parameter manager module rubbed through and shorted to ground or to the engine block
      • Open 5 V reference or open signal wire that lets the input drop to zero
      • Corroded or backed-out pin in the route parameter manager module connector

      Checks

      1. 1Key on, unplug the route parameter manager module and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
      2. 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
      3. 3Measure resistance from the route parameter manager module signal wire to ground with the ECM unplugged to find a short
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Route parameter manager module - voltage low (shorted to a low source)

    • Cummins 6744Route parameter manager module: Out of calibration

      The ECM reports the route parameter manager module as out of calibration: the value or setting it received does not match what the ECM was programmed to expect.· Part or controller
      Check soon

      Causes

      • Parameter set for a feature that is not fitted on this vehicle
      • Wrong or outdated calibration in the ECM
      • Source module sending an invalid or unscaled value for the route parameter manager module

      Checks

      1. 1Compare the ECM parameters with the vehicle equipment, especially those that enable the route parameter manager module
      2. 2Reflash the ECM with the correct calibration if the software level does not match
      3. 3Read the source module for its own codes and check its configuration
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Route parameter manager module CAN 1 malfunction1 code

    • Cummins 6741Route parameter manager module CAN 1 malfunction: Special instructions

      The ECM reports a special-instruction fault on the route parameter manager module CAN 1 malfunction.· Lost message
      Info

      Causes

      • Condition described by the manufacturer procedure for this code
      • Related data link or module fault
      • Configuration or software mismatch

      Checks

      1. 1Follow the manufacturer troubleshooting procedure for this code step by step
      2. 2Check the route parameter manager module CAN 1 malfunction wiring, connectors and related module for faults
      3. 3Check the module software and configuration if the procedure points to a mismatch
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Route parameter manager module GPS antenna current1 code

    • Cummins 6742Route parameter manager module GPS antenna current: Condition exists

      Same failure as 5685 on the route parameter manager module GPS antenna current: the same fault condition as 5685, reported for this part.· Other
      Info

      Causes

      • Same causes as 5685, applied to the route parameter manager module GPS antenna current
      • Wiring or connector problem local to the route parameter manager module GPS antenna current

      Checks

      1. 1Check compression, valve lash and the injector for this cylinder after ruling out fuel supply.
      2. 2Work through the checks listed for 5685, starting at the route parameter manager module GPS antenna current and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Route parameter manager module USB malfunction1 code

    • Cummins 6743Route parameter manager module USB malfunction: Root cause not known

      Same failure as 5691 on the route parameter manager module USB malfunction: the same fault condition as 5691, reported for this part.· Other
      Info

      Causes

      • Same causes as 5691, applied to the route parameter manager module USB malfunction
      • Wiring or connector problem local to the route parameter manager module USB malfunction

      Checks

      1. 1Run a cylinder cutout or power balance test in INSITE to confirm which cylinder is weak.
      2. 2Work through the checks listed for 5691, starting at the route parameter manager module USB malfunction and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Route parameter manager module map loading malfunction2 codes

    • Cummins 6745Route parameter manager module map loading malfunction: Bad device or component

      The ECM flags the route parameter manager module map loading malfunction as a bad device or component after a self-test or a response check failed.· Part or controller
      Check soon

      Causes

      • Failed route parameter manager module map loading malfunction or its internal electronics
      • Supply or ground fault that made the self-test fail
      • Connector or harness damage that stops the part from communicating

      Checks

      1. 1Check supply voltage and ground at the route parameter manager module map loading malfunction before replacing it
      2. 2Inspect the route parameter manager module map loading malfunction connector and wiring for water, corrosion and damage
      3. 3Read the route parameter manager module map loading malfunction for any stored status or self-test result with the service tool
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 6746Route parameter manager module map loading malfunction: Condition exists

      Same failure as 5685 on the route parameter manager module map loading malfunction: the same fault condition as 5685, reported for this part.· Other
      Info

      Causes

      • Same causes as 5685, applied to the route parameter manager module map loading malfunction
      • Wiring or connector problem local to the route parameter manager module map loading malfunction

      Checks

      1. 1Check compression, valve lash and the injector for this cylinder after ruling out fuel supply.
      2. 2Work through the checks listed for 5685, starting at the route parameter manager module map loading malfunction and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Route parameter manager module CAN 2 malfunction1 code

    • Cummins 6747Route parameter manager module CAN 2 malfunction: Special instructions

      Same failure as 6741 on the route parameter manager module CAN 2 malfunction: the same fault condition as 6741, reported for this part.· Lost message
      Info

      Causes

      • Same causes as 6741, applied to the route parameter manager module CAN 2 malfunction
      • Wiring or connector problem local to the route parameter manager module CAN 2 malfunction

      Checks

      1. 1Check the CAN 2 wiring and terminators and the other modules on that link.
      2. 2Work through the checks listed for 6741, starting at the route parameter manager module CAN 2 malfunction and its connector
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Route parameter manager module hardware malfunction1 code

    • Cummins 6748Route parameter manager module hardware malfunction: Condition exists

      Same failure as 5685 on the route parameter manager module hardware malfunction: the same fault condition as 5685, reported for this part.· Other
      Info

      Causes

      • Same causes as 5685, applied to the route parameter manager module hardware malfunction
      • Wiring or connector problem local to the route parameter manager module hardware malfunction

      Checks

      1. 1Check compression, valve lash and the injector for this cylinder after ruling out fuel supply.
      2. 2Work through the checks listed for 5685, starting at the route parameter manager module hardware malfunction and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Route parameter manager module flash test malfunction1 code

    • Cummins 6749Route parameter manager module flash test malfunction: Condition exists

      Same failure as 5685 on the route parameter manager module flash test malfunction: the same fault condition as 5685, reported for this part.· Other
      Info

      Causes

      • Same causes as 5685, applied to the route parameter manager module flash test malfunction
      • Wiring or connector problem local to the route parameter manager module flash test malfunction

      Checks

      1. 1Check compression, valve lash and the injector for this cylinder after ruling out fuel supply.
      2. 2Work through the checks listed for 5685, starting at the route parameter manager module flash test malfunction and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Navigation control module1 code

    • Cummins 6753Navigation control module: Abnormal update rate

      Same failure as 5684 on the navigation control module: the same fault condition as 5684, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 5684, applied to the navigation control module
      • Wiring or connector problem local to the navigation control module

      Checks

      1. 1Check the supply, ground and data link at the manager.
      2. 2Work through the checks listed for 5684, starting at the navigation control module and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Route parameter manager module GPS antenna3 codes

    • Cummins 6761Route parameter manager module GPS antenna: Current high / grounded

      The ECM sees too much current, or a shorted path to ground, in the route parameter manager module GPS antenna.· Shorted low
      Check soon

      Causes

      • Wire to the route parameter manager module GPS antenna shorted to ground
      • Failed part drawing excessive current
      • Water or corrosion inside the connector

      Checks

      1. 1Unplug the route parameter manager module GPS antenna and see whether the high-current code goes away, which separates a failed part from a wiring short
      2. 2Measure the resistance from each wire of the route parameter manager module GPS antenna circuit to ground with the ECM unplugged
      3. 3Inspect the connector and harness for pinch points and water entry
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Route parameter manager module GPS antenna - current high or grounded circuit

    • Cummins 6762Route parameter manager module GPS antenna: Abnormal update rate

      Same failure as 5684 on the route parameter manager module GPS antenna: the same fault condition as 5684, reported for this part.· Erratic or implausible
      Check soon

      Causes

      • Same causes as 5684, applied to the route parameter manager module GPS antenna
      • Wiring or connector problem local to the route parameter manager module GPS antenna

      Checks

      1. 1Check the GPS antenna cable and connector and that the antenna has a clear view of the sky.
      2. 2Work through the checks listed for 5684, starting at the route parameter manager module GPS antenna and its connector
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

    • Cummins 6763Route parameter manager module GPS antenna: Current low / open circuit

      The ECM sees too little current, or no current, in the route parameter manager module GPS antenna.· Open circuit
      Check soon

      Causes

      • Broken or pulled-out wire in the harness to the route parameter manager module GPS antenna
      • Connector at the route parameter manager module GPS antenna unplugged, loose or with a pin pushed back
      • Burnt-out coil or element in the part itself

      Checks

      1. 1Unplug the route parameter manager module GPS antenna and measure the resistance of the part itself against the service manual value, since an infinite reading means the part is open
      2. 2Check continuity of both wires between the route parameter manager module GPS antenna connector and the ECM connector
      3. 3Wiggle the harness and connector at the route parameter manager module GPS antenna while watching the live status to catch an intermittent open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Route parameter manager module GPS antenna - current low or open circuit

  • Route parameter manager module GPS antenna input signal1 code

    • Cummins 6764Route parameter manager module GPS antenna input signal: Root cause not known

      Same failure as 5691 on the route parameter manager module GPS antenna input signal: the same fault condition as 5691, reported for this part.· Other
      Info

      Causes

      • Same causes as 5691, applied to the route parameter manager module GPS antenna input signal
      • Wiring or connector problem local to the route parameter manager module GPS antenna input signal

      Checks

      1. 1Run a cylinder cutout or power balance test in INSITE to confirm which cylinder is weak.
      2. 2Work through the checks listed for 5691, starting at the route parameter manager module GPS antenna input signal and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Check the GPS antenna cable and connector for damage and corrosion, and measure its circuit for opens and shorts
  2. 2Check the hybrid controller for its own codes
  3. 3Check the module supply voltage and ground at its connector
  4. 4Check the data link wiring for damage and corrosion
  5. 5Inspect the module and antenna mounting for water ingress and loose connections
  6. 6Read the module status and update rate live to see whether data is being received
  7. 7Check the high-voltage system status with the hybrid tool

Causes

  • GPS antenna cable or connector damaged, open or shorted
  • Hybrid controller offline
  • Antenna or module failed or poorly mounted
  • Data link fault

Most common here: lost message (3 of 21)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: Predictive features such as route-based cruise or gear control stop working and a lamp may light; the engine runs normally.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.