Cummins · Data link
Cummins Connectivity module and over-the-air updates fault codes
The connectivity (telematics) module links the engine to remote services over a cellular connection. The connectivity module can receive firmware and software updates over the air.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 8154 to 16193 are all about the connectivity module and over-the-air updates. The most common failure type is lost message (4 of 17); none needs an immediate stop. Start with this check: check the module power, ground and connector for corrosion and damage.
How urgent are they?
None of the 17 codes here means stop now; 12 can wait until the shift ends, but find the cause before the next one; 5 are information only.
- Check soon12
- Info5
What should I check first?
Check the module power, ground and connector for corrosion and damage
Shared checks17 of 17
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Connectivity module10 codes
Cummins 8154Connectivity module: Bad device or component
The ECM judges the connectivity module to be an internal failure of the device or module. That usually means replacement or reprogramming rather than wiring repair.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the device
- Supply or ground problem causing it to reset
- Corrupt software
Checks
- 1Check supply and ground at the device before condemning it
- 2Reflash with the correct software where possible
- 3Replace the device if the fault persists after the supply tests are good
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 8155Connectivity module: Out of calibration
The ECM reports the connectivity module as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controllerPart or controllerCheck soonCauses
- Sensor or device out of tolerance
- Wrong calibration or learn data after a repair
Checks
- 1Check whether a learn or calibration procedure is needed after the last repair
- 2Compare with a related sensor and replace the part if the offset is real
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 8156Connectivity module: Abnormal update rate
The ECM is not receiving fresh data for the connectivity module at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Cummins 8157Connectivity module: Condition exists
The ECM sets this code when it recognises a defined condition for the connectivity module. It reports that the condition exists rather than naming a failed part.· OtherOtherInfoCauses
- A monitor or protection condition that has been met
- A related fault that set first
Checks
- 1Read the code description and freeze-frame in INSITE for the exact condition
- 2Work the related active codes first, then recheck
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Cummins 8219Connectivity module: Current low / open circuit
The ECM commands the connectivity module but sees little or no current flow. The circuit is open somewhere between the ECM output and the part, or the part's winding is open.· Open circuitOpen circuitCheck soonCauses
- Open wire or a terminal pushed back in the connector
- Open winding in the component
- Blown fuse or failed relay feeding the circuit
Checks
- 1Check continuity from the ECM pin to the connectivity module connector, wiggling the harness as you test
- 2Measure the component resistance with the connector unplugged; an open reading means the part has failed
- 3Check the fuse and relay feeding the circuit
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Connectivity module - current low or open circuit
Cummins 8221Connectivity module: Voltage high / shorted high
The ECM sees the connectivity module signal circuit above its normal voltage range, which points to a short to a power wire or a failed input rather than a real condition.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to a power feed
- Failed input or damaged connector at the module
Checks
- 1Check the wiring and connector for shorts to battery voltage
- 2Compare the reading with the related signal in INSITE
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Connectivity module - voltage high (shorted to a high source)
Cummins 8222Connectivity module: Root cause not known
The ECM detects a problem with the connectivity module but cannot tie it to one specific cause. It is a catch-all result, so the surrounding codes and the freeze-frame matter more than this one alone.· OtherOtherInfoCauses
- A related fault that set first
- An intermittent connection or supply problem
Checks
- 1Read all active and inactive codes and work the others first
- 2Check the supply, ground and connectors of the circuit involved
- 3Read the freeze-frame data for the conditions when it set
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Cummins 8223Connectivity module: Above normal· least severe
The connectivity module is above its normal operating range and the ECM rates it as least severe. The signal itself is valid, so this reflects a real operating condition or a sensor reading that no longer matches reality.· Real conditionReal conditionInfoCauses
- The monitored condition really is too high because of the system it measures
- A related fault that set first and is pushing the reading out of range
Checks
- 1Compare the live connectivity module with a second reading or gauge to see whether the condition is real
- 2Read the freeze-frame for speed, load and temperature when the code set
- 3Clear any other active codes first and retest under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Connectivity module - above normal - least severe
Cummins 8224Connectivity module: Above normal· moderately severe
The connectivity module is above its normal operating range and the ECM rates it as moderately severe. The signal itself is valid, so this reflects a real operating condition or a sensor reading that no longer matches reality.· Real conditionReal conditionCheck soonCauses
- The monitored condition really is too high because of the system it measures
- A related fault that set first and is pushing the reading out of range
Checks
- 1Compare the live connectivity module with a second reading or gauge to see whether the condition is real
- 2Read the freeze-frame for speed, load and temperature when the code set
- 3Clear any other active codes first and retest under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Connectivity module - above normal - moderately severe
Cummins 8225Connectivity module: Network data in error
The ECM received the connectivity module over the data link but the message is flagged as invalid, so it cannot be used. The fault is usually in the sending module or the link, not the ECM.· Lost messageLost messageCheck soonCauses
- Sending module reporting an invalid value
- Data link wiring or connector fault
Checks
- 1Find which module sends the message and read its codes
- 2Check the data link wiring and connectors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Source wording:Connectivity module - network data received in error
Connectivity module RAM memory1 code
Cummins 8197Connectivity module RAM memory: Bad device or component
The ECM judges the connectivity module RAM memory to be an internal failure of the device or module. That usually means replacement or reprogramming rather than wiring repair.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the device
- Supply or ground problem causing it to reset
- Corrupt software
Checks
- 1Check supply and ground at the device before condemning it
- 2Reflash with the correct software where possible
- 3Replace the device if the fault persists after the supply tests are good
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Connectivity module firmware1 code
Cummins 8226Connectivity module firmware: Network data in error
The ECM received the connectivity module firmware over the data link but the message is flagged as invalid, so it cannot be used. The fault is usually in the sending module or the link, not the ECM.· Lost messageLost messageCheck soonCauses
- Sending module reporting an invalid value
- Data link wiring or connector fault
Checks
- 1Find which module sends the message and read its codes
- 2Check the data link wiring and connectors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Source wording:Connectivity module firmware - network data received in error
Connectivity module operating system1 code
Cummins 8227Connectivity module operating system: Network data in error
The ECM received the connectivity module operating system over the data link but the message is flagged as invalid, so it cannot be used. The fault is usually in the sending module or the link, not the ECM.· Lost messageLost messageCheck soonCauses
- Sending module reporting an invalid value
- Data link wiring or connector fault
Checks
- 1Find which module sends the message and read its codes
- 2Check the data link wiring and connectors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Source wording:Connectivity module operating system - network data received in error
Connectivity module firmware (over the air)2 codes
Cummins 15997Connectivity module firmware (over the air): Condition exists
The ECM sets this code when it recognises a defined condition for the connectivity module firmware (over the air). It reports that the condition exists rather than naming a failed part.· OtherOtherInfoCauses
- A monitor or protection condition that has been met
- A related fault that set first
Checks
- 1Read the code description and freeze-frame in INSITE for the exact condition
- 2Work the related active codes first, then recheck
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Cummins 15998Connectivity module firmware (over the air): Condition exists
The ECM sets this code when it recognises a defined condition for the connectivity module firmware (over the air). It reports that the condition exists rather than naming a failed part.· OtherOtherInfoCauses
- A monitor or protection condition that has been met
- A related fault that set first
Checks
- 1Read the code description and freeze-frame in INSITE for the exact condition
- 2Work the related active codes first, then recheck
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Connectivity module temperature sensor2 codes
Cummins 16192Connectivity module temperature sensor: Voltage high / shorted high
The ECM sees the connectivity module temperature sensor signal circuit above its normal voltage band. That points to a short to the 5 V reference or a battery wire, a lost return, or a sensor that failed high, not a real change in what it measures.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V reference or battery voltage in the harness
- Open sensor return wire letting the signal float up
- Sensor failed high or its connector is corroded
Checks
- 1Read the live connectivity module temperature sensor value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
- 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
- 3With the key off, test the signal wire for continuity to the reference and to battery positive
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Connectivity module temperature sensor - voltage high (shorted to a high source)
Cummins 16193Connectivity module temperature sensor: Voltage low / shorted low
The ECM sees the connectivity module temperature sensor signal circuit below its normal voltage band. That is how a short to ground, an open 5 V reference or a sensor that failed low looks, rather than a real change in what it measures.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground in the harness
- Open 5 V reference wire so the signal collapses
- Sensor failed low or its connector is wet or corroded
Checks
- 1Read the live connectivity module temperature sensor value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
- 2Unplug the sensor and check that the 5 V reference arrives at the connector
- 3With the key off, test the signal wire for a short to ground
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Connectivity module temperature sensor - voltage low (shorted to a low source)
Shared checks
Checks, in order
- 1Check the module power, ground and connector for corrosion and damage
- 2Check the cellular signal and battery voltage and let the update finish
- 3Verify the module software is current and the configuration matches the engine
- 4Verify the module software version against the engine configuration
- 5Look at the data link for missing messages between the module and the ECM
- 6Check the module mounting temperature and ventilation
- 7Reflash the module with the service tool if the update repeatedly fails
Causes
- Module supply voltage low or interrupted
- Update interrupted by a poor signal or power loss
- Module software or memory fault
- Corrupt or incompatible software package
Most common here: lost message (4 of 17)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Remote monitoring and over-the-air services may stop.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.