Cummins · Data link
Cummins Data link, fuel level and chassis signals fault codes
J1939 is the CAN-based data link that connects the ECM to the vehicle and other modules. The ECM receives fuel level and other multiplexed values from the vehicle.
More about these partsLess
These are values the ECM gets from other modules or tracks itself: cab temperature, parasitic loads, the malfunction lamp message, auxiliary sensors, the VIN, propulsion state and the oil change interval.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 285 to 15694 are all about the data link, fuel level and chassis signals. The most common failure type is lost message (8 of 25); none needs an immediate stop. Start with this check: check the data link wiring and connectors for damage and corrosion.
How urgent are they?
None of the 25 codes here means stop now; 22 can wait until the shift ends, but find the cause before the next one; 3 are information only.
- Check soon22
- Info3
What should I check first?
Check the data link wiring and connectors for damage and corrosion
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
J1939 data link3 codes
Cummins 285J1939 data link: Message timeout
The ECM did not receive an expected message from another module on the J1939 data link within the allowed time.· Lost messageLost messageCheck soonCauses
- Another module not transmitting (power or ground loss)
- J1939 data link wiring damaged, loose or corroded
- Terminating resistor missing or wrong
Checks
- 1Read all modules in INSITE and see which one is missing
- 2Check the power and ground at the silent module
- 3Check the J1939 high and low wires for continuity and shorts
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Cummins 286J1939 data link: Configuration error
The ECM sees a J1939 configuration error, meaning another module sent a message that does not match the expected configuration.· Lost messageLost messageCheck soonCauses
- Wrong or mismatched module configuration after a replacement
- Software mismatch between modules
- Data link wiring issue
Checks
- 1Check the configuration of the module that was recently changed
- 2Check the software versions of all modules in INSITE for a mismatch
- 3Check the J1939 data link wiring for damage and bad connections
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Cummins 427J1939 data link: Abnormal update rate
The J1939 data link messages are arriving at an unusual rate, which suggests noise, a damaged cable or a dying module.· Lost messageLost messageCheck soonCauses
- Data link wiring with an intermittent short or open
- Connector corrosion
- A module sending too many messages
Checks
- 1Check the J1939 high and low wires for continuity
- 2Check the terminating resistors on the bus, which should read about 60 ohms between CAN high and low with the key off
- 3Look at the data link connectors and splices for corrosion
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine oil change interval1 code
Cummins 649Engine oil change interval: Condition exists
The ECM sets this code when it recognises a defined condition for the engine oil change interval. It reports that the condition exists rather than naming a failed part.· OtherOtherInfoCauses
- A monitor or protection condition that has been met
- A related fault that set first
Checks
- 1Read the code description and freeze-frame in INSITE for the exact condition
- 2Work the related active codes first, then recheck
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Auxiliary equipment sensor input 31 code
Cummins 779Auxiliary equipment sensor input 3: Root cause not known
The ECM detects a problem with the auxiliary equipment sensor input 3 but cannot tie it to one specific cause. It is a catch-all result, so the surrounding codes and the freeze-frame matter more than this one alone.· OtherOtherInfoCauses
- A related fault that set first
- An intermittent connection or supply problem
Checks
- 1Read all active and inactive codes and work the others first
- 2Check the supply, ground and connectors of the circuit involved
- 3Read the freeze-frame data for the conditions when it set
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Fuel level (main tank) sensor circuit2 codes
Cummins 2222Fuel level (main tank) sensor circuit: Voltage high / shorted high
The ECM sees the fuel level (main tank) sensor signal circuit above its normal voltage band. That points to a short to the 5 V reference or a battery wire, a lost return, or a sensor that failed high, not a real change in what it measures.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V reference or battery voltage in the harness
- Open sensor return wire letting the signal float up
- Sensor failed high or its connector is corroded
Checks
- 1Read the live fuel level (main tank) sensor circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
- 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
- 3With the key off, test the signal wire for continuity to the reference and to battery positive
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Fuel level (main tank) sensor circuit - voltage high (shorted to a high source)
Cummins 2223Fuel level (main tank) sensor circuit: Voltage low / shorted low
The ECM sees the fuel level (main tank) sensor signal circuit below its normal voltage band. That is how a short to ground, an open 5 V reference or a sensor that failed low looks, rather than a real change in what it measures.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground in the harness
- Open 5 V reference wire so the signal collapses
- Sensor failed low or its connector is wet or corroded
Checks
- 1Read the live fuel level (main tank) sensor circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
- 2Unplug the sensor and check that the 5 V reference arrives at the connector
- 3With the key off, test the signal wire for a short to ground
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Fuel level (main tank) sensor circuit - voltage low (shorted to a low source)
Malfunction indicator lamp1 code
Cummins 3535Malfunction indicator lamp: Abnormal update rate
The ECM is not receiving fresh data for the malfunction indicator lamp at the expected rate, so the value is late or has stopped updating.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Wiring or connector contact fault
- Sending module offline or failing
Checks
- 1Check the wiring and connector for loose terminals
- 2Look for related data link or module faults
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Estimated engine parasitic losses4 codes
Cummins 3838Estimated engine parasitic losses: Abnormal update rate
The ECM is not receiving fresh data for the estimated engine parasitic losses at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Cummins 6637Estimated engine parasitic losses: Erratic reading
The ECM judges the estimated engine parasitic losses to be erratic, intermittent or implausible. The value jumps, drifts or disagrees with a related reading, which suggests a poor connection or a failing sensor.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent connector or wiring contact
- Sensor ageing or failing
- A real fluctuation in the system it measures
Checks
- 1Watch the estimated engine parasitic losses live and wiggle the harness and connector to catch dropouts
- 2Compare it with a related sensor to see which one is wrong
- 3Check the connector for moisture and corrosion
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Estimated engine parasitic losses - data erratic or incorrect
Cummins 15693Estimated engine parasitic losses: Erratic reading
The ECM judges the estimated engine parasitic losses to be erratic, intermittent or implausible. The value jumps, drifts or disagrees with a related reading, which suggests a poor connection or a failing sensor.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent connector or wiring contact
- Sensor ageing or failing
- A real fluctuation in the system it measures
Checks
- 1Watch the estimated engine parasitic losses live and wiggle the harness and connector to catch dropouts
- 2Compare it with a related sensor to see which one is wrong
- 3Check the connector for moisture and corrosion
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Estimated engine parasitic losses - data erratic or incorrect
Cummins 15694Estimated engine parasitic losses: Abnormal update rate
The ECM is not receiving fresh data for the estimated engine parasitic losses at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Vehicle identification number1 code
Cummins 4517Vehicle identification number: Out of calibration
The ECM reports the vehicle identification number as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Part or controllerPart or controllerCheck soonCauses
- Parameter set for a feature that is not fitted
- Wrong or outdated calibration in the ECM
- Source module sending an invalid value
Checks
- 1Compare the ECM parameters with the vehicle equipment
- 2Reflash the ECM with the correct calibration
- 3Read the source module for its own codes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
J1939 network #11 code
Cummins 6338J1939 network #1: Out of calibration
The ECM reports the J1939 network #1 as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Lost messageLost messageCheck soonCauses
- Parameter set for a feature that is not fitted
- Wrong or outdated calibration in the ECM
- Source module sending an invalid value
Checks
- 1Compare the ECM parameters with the vehicle equipment
- 2Reflash the ECM with the correct calibration
- 3Read the source module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
SAE J1939 multiplexing PGN timeout error2 codes
Cummins 6339SAE J1939 multiplexing PGN timeout error: Abnormal update rate
The ECM is not receiving fresh data for the SAE J1939 multiplexing PGN timeout error at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Cummins 6342SAE J1939 multiplexing PGN timeout error: Abnormal update rate
The ECM is not receiving fresh data for the SAE J1939 multiplexing PGN timeout error at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
SAE J1939 multiplexing configuration error2 codes
Cummins 6341SAE J1939 multiplexing configuration error: Out of calibration
The ECM reports the SAE J1939 multiplexing configuration error as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Part or controllerPart or controllerCheck soonCauses
- Parameter set for a feature that is not fitted
- Wrong or outdated calibration in the ECM
- Source module sending an invalid value
Checks
- 1Compare the ECM parameters with the vehicle equipment
- 2Reflash the ECM with the correct calibration
- 3Read the source module for its own codes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 6343SAE J1939 multiplexing configuration error: Out of calibration
The ECM reports the SAE J1939 multiplexing configuration error as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Part or controllerPart or controllerCheck soonCauses
- Parameter set for a feature that is not fitted
- Wrong or outdated calibration in the ECM
- Source module sending an invalid value
Checks
- 1Compare the ECM parameters with the vehicle equipment
- 2Reflash the ECM with the correct calibration
- 3Read the source module for its own codes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Propulsion system active1 code
Cummins 6412Propulsion system active: Root cause not known
The ECM detects a problem with the propulsion system active but cannot tie it to one specific cause. It is a catch-all result, so the surrounding codes and the freeze-frame matter more than this one alone.· OtherOtherInfoCauses
- A related fault that set first
- An intermittent connection or supply problem
Checks
- 1Read all active and inactive codes and work the others first
- 2Check the supply, ground and connectors of the circuit involved
- 3Read the freeze-frame data for the conditions when it set
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Cab interior temperature2 codes
Cummins 8344Cab interior temperature: Abnormal update rate
The ECM is not receiving fresh data for the cab interior temperature at the expected rate, so the value is late or has stopped updating.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Wiring or connector contact fault
- Sending module offline or failing
Checks
- 1Check the wiring and connector for loose terminals
- 2Look for related data link or module faults
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Cummins 8347Cab interior temperature: Out of calibration
The ECM reports the cab interior temperature as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controllerPart or controllerCheck soonCauses
- Sensor or device out of tolerance
- Wrong calibration or learn data after a repair
Checks
- 1Check whether a learn or calibration procedure is needed after the last repair
- 2Compare with a related sensor and replace the part if the offset is real
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Fuel level 12 codes
Cummins 15686Fuel level 1: Out of calibration
The ECM reports the fuel level 1 as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controllerPart or controllerCheck soonCauses
- Sensor or device out of tolerance
- Wrong calibration or learn data after a repair
Checks
- 1Check whether a learn or calibration procedure is needed after the last repair
- 2Compare with a related sensor and replace the part if the offset is real
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 15687Fuel level 1: Abnormal update rate
The ECM is not receiving fresh data for the fuel level 1 at the expected rate, so the value is late or has stopped updating.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Wiring or connector contact fault
- Sending module offline or failing
Checks
- 1Check the wiring and connector for loose terminals
- 2Look for related data link or module faults
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Fuel level 22 codes
Cummins 15688Fuel level 2: Out of calibration
The ECM reports the fuel level 2 as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controllerPart or controllerCheck soonCauses
- Sensor or device out of tolerance
- Wrong calibration or learn data after a repair
Checks
- 1Check whether a learn or calibration procedure is needed after the last repair
- 2Compare with a related sensor and replace the part if the offset is real
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 15689Fuel level 2: Abnormal update rate
The ECM is not receiving fresh data for the fuel level 2 at the expected rate, so the value is late or has stopped updating.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Wiring or connector contact fault
- Sending module offline or failing
Checks
- 1Check the wiring and connector for loose terminals
- 2Look for related data link or module faults
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Shared checks
Checks, in order
- 1Check the data link wiring and connectors for damage and corrosion
- 2Check the source module for its own codes and power supply
- 3Check the termination resistors at both ends of the link
- 4Check the data link wiring for damage and corrosion
- 5Unplug modules one at a time and see whether the link recovers
- 6Verify the message configuration matches the vehicle
- 7Check the related ECM parameters against the vehicle configuration
Causes
- Damaged data link wiring or connector
- Message source module offline
- Source module offline or faulted
- Missing or failed termination
Most common here: lost message (8 of 25)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Several modules may report missing messages, and features that depend on the data link may stop working.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Cummins ISX15 (2013-2018) Fault Codes List (Diesel Repair)
- Cummins ISX15 (2010-2012) Fault Code List (Diesel Repair)
- Cummins ISB6.7 (2013-2018) Fault Code List (Diesel Repair)
- Cummins L9 (2024-2025) Fault Code List (Diesel Repair)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.