Bobcat · Electrical

Bobcat Rear light relays, outputs and lights controller fault codes

The rear light relays and outputs switch the rear lamp circuits, and the lights controller supplies them. A code names the relay, output or controller fault: error on, error off, open circuit, interrupted power, communication loss or a program problem.

FaultCheckU109C-08Bobcat · Rear light relays, outputs and lights controller
Code shows hereFAULTU109C-08

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes U109C-08 to M5128 are all about the rear light relays, outputs and lights controller. The most common failure type is shorted low (2 of 10); none needs an immediate stop. Start with this check: check whether all the rear lamps fail together; that points to the relay, output or lights controller rather than a lamp.

How urgent are they?

None of the 10 codes here means stop now; all 10 can wait until the shift ends, but find the cause before the next one.

  • Check soon10

What should I check first?

Check whether all the rear lamps fail together; that points to the relay, output or lights controller rather than a lamp.

Shared checks

10 of 10

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat U109C-08Lights controller communication error

    The controller reports a failure on the lights controller communication without saying whether it is open, shorted or stuck, so lighting functions may be limited or off.· Lost message
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the lights controller connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the lights controller communication; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the lights controller connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    4. 4Check the fuse and ground for the lights controller and look for a loose connector on the lights controller itself before replacing it.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat U109C-51Lights controller not programmed

    The lights controller has no valid program loaded, so the controller will not run its functions and lighting functions may be limited or off.· Other
    Check soon

    Causes

    • New or replaced controller never programmed
    • Software update interrupted
    • Memory corrupted

    Checks

    1. 1Program the lights controller with the dealer service tool and the correct software for the machine model.
    2. 2Check that supply stayed steady during the last update.
    3. 3After programming, calibrate and clear the code.
    4. 4Check the fuse and ground for the lights controller and look for a loose connector on the lights controller itself before replacing it.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U109C-57Lights controller software incompatible

    The software in the lights controller does not match the rest of the machine, so lighting functions may be limited or off.· Part or controller
    Check soon

    Causes

    • Controller replaced with a different software version
    • Update applied to one controller only
    • Wrong software file loaded

    Checks

    1. 1Read the software versions of each controller on the service screen.
    2. 2Update the lights controller to the version that matches the machine through the dealer service tool.
    3. 3Clear the code and restart to confirm the versions agree.
    4. 4Check the fuse and ground for the lights controller and look for a loose connector on the lights controller itself before replacing it.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat U1075-00Lights controller interrupted power failure

    The lights controller failure lost its supply briefly while the machine was running, so lighting functions may be limited or off.· Part or controller
    Check soon

    Causes

    • Battery terminal or main ground loose
    • Supply fuse or connector intermittent
    • Low battery during cranking

    Checks

    1. 1Check battery terminals and the main ground strap for tight clean connections.
    2. 2Check the controller supply fuse and connector for heat marks.
    3. 3Clear the code and watch whether it returns after the next start.
    4. 4Check the fuse and ground for the lights controller and look for a loose connector on the lights controller itself before replacing it.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat M4902Rear light relay error on

    The controller sees the rear light relay switched on when it was commanded off, so the lights stay on.· Lost message
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the rear light relay at the rear light relay socket with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the relay and its socket energising while it should be off.
    4. 4Press the relay socket terminals for heat marks, and measure the coil resistance of the relay out of its socket.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M4903Rear light relay error off

    The controller sees the rear light relay off when it was commanded on, so the rear lights do not switch.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The relay and its socket failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the rear light relay circuit with the key on.
    2. 2Measure the resistance of the relay and its socket and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the rear light relay plug; none means a wiring or controller fault.
    4. 4Press the relay socket terminals for heat marks, and measure the coil resistance of the relay out of its socket.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M5102Rear light output error on

    The controller sees the rear light output switched on when it was commanded off, so the lights stay on.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the rear light output at the rear light output connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the lamp feed energising while it should be off.
    4. 4Check the rear harness plug at the frame joint for water and corrosion, which affects several rear lamps together.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M5103Rear light output error off

    The controller sees the rear light output off when it was commanded on, so the rear lights do not switch as commanded.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The lamp feed failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the rear light output circuit with the key on.
    2. 2Measure the resistance of the lamp feed and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the rear light output plug; none means a wiring or controller fault.
    4. 4Check the rear harness plug at the frame joint for water and corrosion, which affects several rear lamps together.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M5107Rear light output open circuit

    The controller sees an open circuit on the rear light output, so no current can flow through it and the rear lights do not switch as commanded.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the rear light output connector
    • Wire broken inside its insulation near a bend or clamp
    • The lamp feed burnt open or its internal lead broken

    Checks

    1. 1Check that the rear light output connector at the rear light output connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the lamp feed with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the rear light output plug back to the controller connector, flexing the harness as you go.
    4. 4Check the rear harness plug at the frame joint for water and corrosion, which affects several rear lamps together.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M5128Rear light output failure

    The controller reports a failure on the rear light output without saying whether it is open, shorted or stuck, so the rear lights do not switch as commanded.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the rear light output connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the rear light output; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the rear light output connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    4. 4Check the rear harness plug at the frame joint for water and corrosion, which affects several rear lamps together.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Check whether all the rear lamps fail together; that points to the relay, output or lights controller rather than a lamp.
  2. 2Swap the rear light relay with an identical one and see whether the code follows it.
  3. 3Check the lights controller fuse, supply and ground at its connector.
  4. 4Check CAN wiring at the lights controller for chafing and water.
  5. 5After a controller change, program the lights controller through the dealer service tool.

Causes

  • Rear light relay stuck or its socket burnt
  • Output driver failed after an earlier short
  • Lights controller supply, ground or CAN connection lost
  • Lights controller not programmed or on incompatible software

Most common here: shorted low (2 of 10)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: Several rear lamps misbehave together, the lights stay on, or the lights controller reports a fault on the panel.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.