Bobcat DPF regeneration, DeSOx and DEF messages fault codes

On Tier 4 engines the diesel particulate filter burns off soot in a regeneration. These codes are status and request messages: regeneration active, needed, inhibited, remote or service regeneration required, switch faults and DeSOx or DEF messages from the aftertreatment system.

FaultCheckM5902Bobcat · DPF regeneration, DeSOx and DEF messages
Code shows hereFAULTM5902

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes M5902 to M8564 are all about the dPF regeneration, DeSOx and DEF messages. The most common failure type is real condition (2 of 19); none needs an immediate stop. Start with this check: read the message literally: active means wait, required means park and start a regeneration, service required means the dealer must run a forced regeneration.

How urgent are they?

None of the 19 codes here means stop now; 10 can wait until the shift ends, but find the cause before the next one; 9 are information only.

  • Check soon10
  • Info9

What should I check first?

Read the message literally: active means wait, required means park and start a regeneration, service required means the dealer must run a forced regeneration.

Shared checks

19 of 19

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat M5902DPF regeneration switch error on

    The controller sees the dpf regeneration switch switched on when it was commanded off, so the switch is read as pressed all the time.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the dpf regeneration switch at the switch plug under the instrument panel with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the switch contacts energising while it should be off.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6002DPF inhibit regen switch error on

    The controller sees the dpf inhibit regen switch switched on when it was commanded off, so the switch is read as pressed all the time.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the dpf inhibit regen switch at the switch plug under the instrument panel with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the switch contacts energising while it should be off.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6102Remote parked regeneration switch error on

    The controller sees the remote parked regeneration switch switched on when it was commanded off, so the switch is read as pressed all the time.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the remote parked regeneration switch at the switch plug under the instrument panel with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the switch contacts energising while it should be off.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8228AdBlue/DEF sensor mismatch

    The AdBlue (DEF) level or quality sensor reading does not agree with what the system expects, so the aftertreatment controller cannot trust the DEF information and may limit the engine.· Other
    Check soon

    Causes

    • DEF tank filled with the wrong fluid or diluted DEF
    • DEF sensor or its connector damaged
    • Cold DEF that has not thawed yet

    Checks

    1. 1Check the DEF tank contains clean DEF, and drain and refill with correct fluid if it is contaminated.
    2. 2Look at the DEF sensor connector in the tank for corrosion and damage.
    3. 3Let a frozen tank thaw with the engine running, then clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8402DeSOx service requested

    The machine is asking for a DeSOx service, a high-temperature cleaning run that removes sulphur built up in the aftertreatment system, which is needed after running on high-sulphur fuel.· Other
    Check soon

    Causes

    • High-sulphur fuel used
    • Long periods at low load keeping exhaust temperature down

    Checks

    1. 1Check what fuel was used and refuel with low-sulphur diesel.
    2. 2Start the DeSOx service from the panel when the machine is parked outdoors and let it finish.
    3. 3Contact the dealer if the request returns soon after.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8450DeSOx required but inhibited

    A DeSOx cleaning is required but the controller has inhibited it, usually because a switch is set to inhibit or the engine conditions are not right for the high-temperature run.· Other
    Check soon

    Causes

    • Inhibit switch set
    • Engine temperature or load not suitable
    • Another aftertreatment fault blocking the run

    Checks

    1. 1Turn off the inhibit switch and repeat the request.
    2. 2Check for other active engine codes that block the cleaning run.
    3. 3Warm the engine fully and park outdoors before retrying.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8541DPF automatic regeneration active

    This is a status message, not a fault: the DPF is cleaning itself by an automatic regeneration, burning off soot at high exhaust temperature while you work.· Other
    Info

    Causes

    • Soot load reached the limit and the engine started a regeneration
    • Exhaust temperature raised on purpose by the engine controller

    Checks

    1. 1Keep working normally or let the machine idle until the message clears.
    2. 2Do not shut the engine off during the regeneration; keep flammable material away from the exhaust.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8542DPF automatic regeneration active

    DPF automatic regeneration active: same fault as M8541 (an automatic regeneration is running), here on the dpf automatic regeneration active.· Other
    Info

    Causes

    • Soot load reached the limit and the engine started a regeneration
    • Exhaust temperature raised on purpose by the engine controller

    Checks

    1. 1Keep the engine running until the message clears.
    2. 2Test steps: see M8541.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8543DPF regeneration required

    The DPF has collected enough soot that a regeneration is required, but the machine has not started one itself, usually because the work cycle is too light to heat the exhaust.· Other
    Check soon

    Causes

    • Long light-duty running or idling
    • Regeneration inhibit active
    • Exhaust temperature too low

    Checks

    1. 1Start a parked regeneration from the panel and let it complete.
    2. 2Make sure the inhibit switch is not set.
    3. 3Run the machine under load for longer periods after the regeneration.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8551DPF regeneration needed inhibit active

    A regeneration is needed but the inhibit function is active, so the controller will not start it until the inhibit is released; soot keeps building meanwhile.· Other
    Info

    Causes

    • DPF inhibit switch pressed or stuck
    • Inhibit requested from another switch

    Checks

    1. 1Release the DPF inhibit switch and check it returns to its resting position.
    2. 2Start a regeneration from the panel once the inhibit is off.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8552DPF regeneration needed - Inhibit active

    DPF regeneration needed - inhibit active: same fault as M8551 (a regeneration is needed but inhibited), here on the dpf regeneration needed inhibit active.· Other
    Info

    Causes

    • DPF inhibit switch pressed or stuck
    • Inhibit requested from another switch

    Checks

    1. 1Release the inhibit switch and start a regeneration.
    2. 2Test steps: see M8551.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8553DPF remote parked regeneration required - Remote regeneration kit required

    A parked regeneration is required and it can only be done with the remote regeneration kit, so the machine itself cannot start the cleaning.· Lost message
    Check soon

    Causes

    • Machine configured to need the remote kit
    • Soot load too high for the normal methods

    Checks

    1. 1Connect the remote regeneration kit as the manual describes and start the regeneration.
    2. 2Contact the dealer if the kit is not available.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M8554DPF service regeneration required - Contact bobcat dealer

    The soot load is too high for a normal regeneration, so a service regeneration must be run by the dealer with the service tool.· Real condition
    Check soon

    Causes

    • Repeated regenerations interrupted or inhibited
    • Soot load beyond the normal regeneration limit

    Checks

    1. 1Contact a Bobcat dealer for a service regeneration.
    2. 2Avoid further heavy work until it is done.
    3. 3Ask the dealer to check the exhaust back-pressure sensor.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat M8555DPF service required

    The DPF needs service: a normal regeneration cannot clear it, so the filter needs a dealer service or cleaning.· Other
    Check soon

    Causes

    • Ash or soot beyond what regeneration can clear
    • Filter damaged or blocked

    Checks

    1. 1Contact a Bobcat dealer for DPF service.
    2. 2Check for other aftertreatment codes before the dealer visit.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8560DPF service regeneration active

    This is a status message, not a fault: a service regeneration started with the dealer tool is running, cleaning the DPF at high temperature.· Real condition
    Info

    Causes

    • Service regeneration was started with the service tool
    • Dealer is clearing a high soot load

    Checks

    1. 1Let the service regeneration finish; do not shut the engine off.
    2. 2Keep the exhaust clear of flammable material.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat M8561DPF service regeneration active

    DPF service regeneration active: same fault as M8560 (a service regeneration is running), here on the dpf service regeneration active.· Other
    Info

    Causes

    • Service regeneration was started with the service tool
    • Dealer is clearing a high soot load

    Checks

    1. 1Let the service regeneration finish.
    2. 2Test steps: see M8560.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8562DPF service regeneration active

    DPF service regeneration active: same fault as M8560 (a service regeneration is running), here on the dpf service regeneration active.· Other
    Info

    Causes

    • Service regeneration was started with the service tool
    • Dealer is clearing a high soot load

    Checks

    1. 1Let the service regeneration finish.
    2. 2Test steps: see M8560.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8563DPF service regeneration active

    DPF service regeneration active: same fault as M8560 (a service regeneration is running), here on the dpf service regeneration active.· Other
    Info

    Causes

    • Service regeneration was started with the service tool
    • Dealer is clearing a high soot load

    Checks

    1. 1Let the service regeneration finish.
    2. 2Test steps: see M8560.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8564DPF service regeneration active

    DPF service regeneration active: same fault as M8560 (a service regeneration is running), here on the dpf service regeneration active.· Other
    Info

    Causes

    • Service regeneration was started with the service tool
    • Dealer is clearing a high soot load

    Checks

    1. 1Let the service regeneration finish.
    2. 2Test steps: see M8560.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Read the message literally: active means wait, required means park and start a regeneration, service required means the dealer must run a forced regeneration.
  2. 2Check that the inhibit and regeneration switches are not stuck and that the panel shows the expected lamp state when each is pressed.
  3. 3Park outdoors on a non-flammable surface and keep the machine running through the whole regeneration; shutting down early causes repeat codes.
  4. 4Check DEF level and quality where fitted, and look for other active engine or sensor codes that stop a regeneration.
  5. 5If the service message returns quickly after a regeneration, have the exhaust back-pressure and sensors checked by the dealer.

Causes

  • Soot loading from long idling or light-duty work, so a regeneration is simply due
  • Regeneration inhibit switch left pressed or its circuit shorted
  • Exhaust or aftertreatment sensor fault blocking a regeneration
  • Low DEF level or poor-quality DEF on machines with SCR

Most common here: real condition (2 of 19)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A DPF lamp, regeneration request or service message shows; exhaust temperature rises during a regeneration and engine speed may be raised automatically.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.