Bobcat · Engine
Bobcat Cooling, reverse, hydraulic and tailgate fans fault codes
Bobcat machines cool the radiator and hydraulic cooler with an engine fan, hydraulic or electric fans, a reversing fan that blows debris out of the cores and, on some models, two tailgate fans. A code names the fan output or relay and whether the controller sees it on, off, open or shorted.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes VPV004-05 to M8030 are all about the cooling, reverse, hydraulic and tailgate fans. The most common failure type is shorted low (11 of 38); none needs an immediate stop. Start with this check: run the fan test or reverse cycle from the service menu and watch whether the fan responds; no response means look at the output circuit.
How urgent are they?
None of the 38 codes here means stop now; all 38 can wait until the shift ends, but find the cause before the next one.
- Check soon38
What should I check first?
Run the fan test or reverse cycle from the service menu and watch whether the fan responds; no response means look at the output circuit.
Shared checks38 of 38
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat VPV004-05Fan control P/V (j), current below normal
The controller measured less current than expected through the fan control valve while commanding it, which usually means an open wire, a poor connection or a coil that has failed open, so the cooling fan does not respond to temperature and the machine can overheat.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded at the fan connector near the radiator
- Wire broken near a bend
- Controller output weak
Checks
- 1Measure the resistance of the fan control output with the plug off; an open or very high reading confirms the part.
- 2Check the fan control valve connector at the fan connector near the radiator for corrosion and for pins pushed back in the shell.
- 3Check the wire for resistance between the controller and the plug while flexing the harness.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VSV004-05Reverse fan S/V (d), current below normal
The controller measured less current than expected through the reverse fan while commanding it, which usually means an open wire, a poor connection or a coil that has failed open, so the reverse cleaning cycle does not run and debris stays in the cores.· Open circuitOpen circuitCheck soonCauses
- Coil open or very high resistance
- Connector pin backed out or corroded at the reverse fan valve on the fan drive
- Wire broken near a bend
- Controller output weak
Checks
- 1Measure the resistance of the reverse fan solenoid coil with the plug off; an open or very high reading confirms the part.
- 2Check the reverse fan connector at the reverse fan valve on the fan drive for corrosion and for pins pushed back in the shell.
- 3Check the wire for resistance between the controller and the plug while flexing the harness.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat VPV004-06Fan control P/V (j), current above normal
The controller measured more current than expected through the fan control valve while commanding it, which points to a shorted coil or a wire shorted to ground, and the cooling fan does not respond to temperature and the machine can overheat until it is cleared.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground at the fan connector near the radiator
- Water in the connector
- Wrong part fitted
Checks
- 1Measure the resistance of the fan control output with the plug off and compare it with a matching part.
- 2Test the fan control valve output wire to ground with the plug off for a short.
- 3Look at the harness at the fan connector near the radiator for chafing that shorts to ground only when the machine moves.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat VSV004-06Reverse fan S/V (d), current above normal
The controller measured more current than expected through the reverse fan while commanding it, which points to a shorted coil or a wire shorted to ground, and the reverse cleaning cycle does not run and debris stays in the cores until it is cleared.· Shorted lowShorted lowCheck soonCauses
- Coil shorted between turns
- Wire chafed to ground at the reverse fan valve on the fan drive
- Water in the connector
- Wrong part fitted
Checks
- 1Measure the resistance of the reverse fan solenoid coil with the plug off and compare it with a matching part.
- 2Test the reverse fan output wire to ground with the plug off for a short.
- 3Look at the harness at the reverse fan valve on the fan drive for chafing that shorts to ground only when the machine moves.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat 35-02Two-speed fan error on
The controller sees the two speed fan switched on when it was commanded off, so the fan runs flat out. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the two speed fan at the fan connector near the radiator with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the fan control output energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 35-03Two-speed fan error off
The controller sees the two speed fan off when it was commanded on, so the cooling fan does not respond to temperature and the machine can overheat. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The fan control output failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the two speed fan circuit with the key on.
- 2Measure the resistance of the fan control output and look for an open or a short to its body.
- 3Command the function and measure voltage at the two speed fan plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C102B-11Reverse fan short to ground
The controller reads the reverse fan circuit pulled to ground, so it cannot drive the load. The output is shut off and the reverse cleaning cycle does not run and debris stays in the cores until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the reverse fan valve on the fan drive
- The reverse fan solenoid coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the reverse fan output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the reverse fan solenoid coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the reverse fan valve on the fan drive.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C102B-12Reverse fan short to battery
The controller reads the reverse fan circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the reverse cleaning cycle does not run and debris stays in the cores.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the reverse fan valve on the fan drive and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the reverse fan at the reverse fan valve on the fan drive and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the reverse fan solenoid coil for chafing next to live supply wires and for melted insulation.
- 3Replace the reverse fan solenoid coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat C102B-13Reverse fan open circuit
The controller sees an open circuit on the reverse fan, so no current can flow through it and the reverse cleaning cycle does not run and debris stays in the cores. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the reverse fan valve on the fan drive
- Wire broken inside its insulation near a bend or clamp
- The reverse fan solenoid coil burnt open or its internal lead broken
Checks
- 1Check that the reverse fan connector at the reverse fan valve on the fan drive is fully seated and its lock tab engaged.
- 2Measure the resistance of the reverse fan solenoid coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the reverse fan plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H2105Reverse fan solenoid short to battery
Reverse fan solenoid short to battery: same fault as C102B-12 (the circuit reads tied to battery voltage), here on the reverse fan solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the reverse fan solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see C102B-12.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H2106Reverse fan solenoid short to ground
Reverse fan solenoid short to ground: same fault as C102B-11 (the circuit reads pulled to ground), here on the reverse fan solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The reverse fan solenoid coil shorted to its housing
Checks
- 1Test the reverse fan solenoid output wire to chassis ground with the plug off.
- 2Test steps: see C102B-11.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H2107Reverse fan solenoid open circuit
Reverse fan solenoid open circuit: same fault as C102B-13 (the circuit is open), here on the reverse fan solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the reverse fan solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see C102B-13.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H2132Reverse fan solenoid overcurrent
The controller measured too much current on the reverse fan output and switched it off to protect its driver, so the reverse cleaning cycle does not run and debris stays in the cores until the overload is cleared.· Real conditionReal conditionCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground at the reverse fan valve on the fan drive
- Wrong or damaged part fitted that loads the output
Checks
- 1Measure the resistance of the reverse fan solenoid coil with the plug off and compare it with a matching part on the same machine.
- 2Check the reverse fan wire for a partial short to ground that only shows when the machine is hot or vibrating.
- 3Replace the part and clear the code; if it returns at once, suspect the controller output.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M3505Hydraulic fan short to battery
The controller reads the hydraulic fan circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the hydraulic fan speed is not controlled.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the hydraulic fan valve and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the hydraulic fan at the hydraulic fan valve and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the fan valve coil for chafing next to live supply wires and for melted insulation.
- 3Replace the fan valve coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M3506Hydraulic fan short to ground
The controller reads the hydraulic fan circuit pulled to ground, so it cannot drive the load. The output is shut off and the hydraulic fan speed is not controlled until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the hydraulic fan valve
- The fan valve coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the hydraulic fan output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the fan valve coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the hydraulic fan valve.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M3507Hydraulic fan open circuit
The controller sees an open circuit on the hydraulic fan, so no current can flow through it and the hydraulic fan speed is not controlled. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the hydraulic fan valve
- Wire broken inside its insulation near a bend or clamp
- The fan valve coil burnt open or its internal lead broken
Checks
- 1Check that the hydraulic fan connector at the hydraulic fan valve is fully seated and its lock tab engaged.
- 2Measure the resistance of the fan valve coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the hydraulic fan plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M3532Hydraulic fan overcurrent
The controller measured too much current on the hydraulic fan output and switched it off to protect its driver, so the hydraulic fan speed is not controlled until the overload is cleared.· Real conditionReal conditionCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground at the hydraulic fan valve
- Wrong or damaged part fitted that loads the output
Checks
- 1Measure the resistance of the fan valve coil with the plug off and compare it with a matching part on the same machine.
- 2Check the hydraulic fan wire for a partial short to ground that only shows when the machine is hot or vibrating.
- 3Replace the part and clear the code; if it returns at once, suspect the controller output.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M6202Tailgate fan 1 error on
The controller sees the tailgate fan switched on when it was commanded off, so the fan runs when it should be off. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the tailgate fan at the tailgate fan connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the fan motor energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6203Tailgate fan 1 error off
The controller sees the tailgate fan off when it was commanded on, so that tailgate fan does not run, so cooling air is reduced. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The fan motor failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the tailgate fan circuit with the key on.
- 2Measure the resistance of the fan motor and look for an open or a short to its body.
- 3Command the function and measure voltage at the tailgate fan plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M6228Tailgate fan 1 failure
The controller reports a failure on the tailgate fan without saying whether it is open, shorted or stuck, so that tailgate fan does not run, so cooling air is reduced. It is a general output fault rather than one failure mode.· OtherOtherCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector at the tailgate fan connector
- Intermittent break in the harness
- Controller output stage failed
Checks
- 1Read the other active codes for the tailgate fan; a short or open code beside this one narrows the cause.
- 2Reseat the connector at the tailgate fan connector and clear the code to see whether it returns.
- 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6302Tailgate fan 2 error on
Tailgate fan 2 error on: same fault as M6202 (the output reads on when it should be off), here on the tailgate fan 2.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the tailgate fan 2 with the key on and see whether the controller still reads it on.
- 2Test steps: see M6202.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6303Tailgate fan 2 error off
Tailgate fan 2 error off: same fault as M6203 (the output reads off when it was commanded on), here on the tailgate fan 2.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The fan motor failed open
Checks
- 1Check the fuse and the supply voltage at the tailgate fan 2 plug with the output commanded.
- 2Test steps: see M6203.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6328Tailgate fan 2 failure
Tailgate fan 2 failure: same fault as M6228 (the controller reports a general output failure), here on the tailgate fan 2.· OtherOtherCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector
Checks
- 1Read the other active codes for the tailgate fan 2 and reseat its connector.
- 2Test steps: see M6228.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M7102Electric fan output error on
The controller sees the electric fan output switched on when it was commanded off, so the fan runs continuously. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the electric fan output at the fan motor connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the fan motor circuit energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M7103Electric fan output error off
The controller sees the electric fan output off when it was commanded on, so the electric fan does not run and the radiator is not cooled at low speed. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The fan motor circuit failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the electric fan output circuit with the key on.
- 2Measure the resistance of the fan motor circuit and look for an open or a short to its body.
- 3Command the function and measure voltage at the electric fan output plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M7107Electric fan output open circuit
The controller sees an open circuit on the electric fan output, so no current can flow through it and the electric fan does not run and the radiator is not cooled at low speed. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the fan motor connector
- Wire broken inside its insulation near a bend or clamp
- The fan motor circuit burnt open or its internal lead broken
Checks
- 1Check that the electric fan output connector at the fan motor connector is fully seated and its lock tab engaged.
- 2Measure the resistance of the fan motor circuit with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the electric fan output plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M7202Electric fan relay error on
The controller sees the electric fan relay switched on when it was commanded off, so the fan runs continuously. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the electric fan relay at the fan motor connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the fan motor circuit energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M7203Electric fan relay error off
The controller sees the electric fan relay off when it was commanded on, so the electric fan does not run and the radiator is not cooled at low speed. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The fan motor circuit failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the electric fan relay circuit with the key on.
- 2Measure the resistance of the fan motor circuit and look for an open or a short to its body.
- 3Command the function and measure voltage at the electric fan relay plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M8004Cooling fan controller no communication
The controller has lost communication with the cooling fan controller, so the cooling fan does not respond to temperature and the machine can overheat. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the fan connector near the radiator
Checks
- 1Measure supply and ground at the cooling fan controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the fan connector near the radiator.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M8005Cooling fan short to battery
The controller reads the cooling fan circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the cooling fan does not respond to temperature and the machine can overheat.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the fan connector near the radiator and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the cooling fan at the fan connector near the radiator and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the fan control output for chafing next to live supply wires and for melted insulation.
- 3Replace the fan control output only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M8006Cooling fan short to ground
The controller reads the cooling fan circuit pulled to ground, so it cannot drive the load. The output is shut off and the cooling fan does not respond to temperature and the machine can overheat until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the fan connector near the radiator
- The fan control output shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the cooling fan output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the fan control output to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the fan connector near the radiator.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M8021Cooling fan out of range high
The controller reads the cooling fan signal above its normal range, which is usually a wire shorted to supply or a sensor that has failed high, so the cooling fan does not respond to temperature and the machine can overheat.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
- Ground wire open so the signal floats high
- Water in the connector bridging signal to supply
Checks
- 1Unplug the cooling fan and measure the signal wire with the key on; a high voltage with the sensor removed means a short in the harness.
- 2Check the sensor ground at the plug; an open ground drives the signal high.
- 3Measure the 5 V reference at the cooling fan plug to confirm it is not above 5 V.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M8022Cooling fan out of range low
The controller reads the cooling fan signal below its normal range, typically a wire shorted to ground, an open supply or a sensor failed low, so the cooling fan does not respond to temperature and the machine can overheat.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
- Sensor failed with its output pinned low
- Pin backed out of the connector
Checks
- 1Measure the 5 V reference at the cooling fan plug; no reference means the fault is in the supply wire, not the sensor.
- 2Unplug the sensor and measure the signal wire to ground for a short.
- 3Check the connector at the fan connector near the radiator for a backed-out pin.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M8025Cooling fan unresponsive
The controller sees no response from the cooling fan when the machine is commanded to move, so the cooling fan does not respond to temperature and the machine can overheat. A sensor that is frozen, disconnected or mechanically stuck looks the same.· Open circuitOpen circuitCheck soonCauses
- Sensor or its linkage stuck
- Connector or supply fault
- Spool or part not moving because of dirt
Checks
- 1Command a movement and watch the cooling fan value on the service screen; no change confirms an unresponsive signal.
- 2Check the sensor connector at the fan connector near the radiator and its supply.
- 3Check the part it measures moves freely by hand where accessible.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M8027Cooling fan CAN error
The controller reports a failure on the cooling fan can without saying whether it is open, shorted or stuck, so the cooling fan does not respond to temperature and the machine can overheat. It is a general output fault rather than one failure mode.· Lost messageLost messageCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector at the fan connector near the radiator
- Intermittent break in the harness
- Controller output stage failed
Checks
- 1Read the other active codes for the cooling fan can; a short or open code beside this one narrows the cause.
- 2Reseat the connector at the fan connector near the radiator and clear the code to see whether it returns.
- 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M8028Cooling fan failure
The controller reports a failure on the cooling fan without saying whether it is open, shorted or stuck, so the cooling fan does not respond to temperature and the machine can overheat. It is a general output fault rather than one failure mode.· Lost messageLost messageCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector at the fan connector near the radiator
- Intermittent break in the harness
- Controller output stage failed
Checks
- 1Read the other active codes for the cooling fan; a short or open code beside this one narrows the cause.
- 2Reseat the connector at the fan connector near the radiator and clear the code to see whether it returns.
- 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M8029Cooling fan wiring fault
The controller found a wiring fault on the cooling fan: the circuit does not behave like a connected, working part, so the cooling fan does not respond to temperature and the machine can overheat.· Lost messageLost messageCheck soonCauses
- Handle or sensor wiring broken inside the cable
- Connector corroded or loose
- Pin backed out at the handle plug
Checks
- 1Unplug the cooling fan connector and check the pins for corrosion and push-out.
- 2Flex the cable near the handle while watching the service screen for the fault to set and clear.
- 3Measure continuity of each wire from the handle plug to the controller.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M8030Cooling fan controller fault
Cooling fan controller fault: same fault as M8028 (the controller reports a general output failure), here on the cooling fan.· Part or controllerPart or controllerCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector
Checks
- 1Read the other active codes for the cooling fan and reseat its connector.
- 2Test steps: see M8028.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Shared checks
Checks, in order
- 1Run the fan test or reverse cycle from the service menu and watch whether the fan responds; no response means look at the output circuit.
- 2Check the relay by swapping it with an identical one and measure coil resistance of the solenoid or valve with the plug off.
- 3Look at the radiator and cooler cores for packed debris; a blocked core can mimic a fan fault.
- 4Inspect the harness at the tailgate hinge and fan shroud for fatigue breaks that only open when the door moves.
- 5Measure supply and ground at the fan connector while the output is commanded.
Causes
- Fan relay or driver stuck on or off
- Reverse fan solenoid or proportional valve coil failed
- Fan motor or hydraulic fan valve sticking
- Harness chafed near the fan shroud or tailgate hinge
Most common here: shorted low (11 of 38)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: The machine runs hot, the fan runs constantly at full speed, or the reverse-fan cleaning cycle does not work.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.