Thermo King Engine starting, glow plugs and engine speed fault codes

This page covers starting and speed: cranking and starting alarms, glow plugs and the intake air heater, engine speed and position sensors, and speed control with forced low speed. The controller starts the diesel by cranking, glow and fuel.

More about these parts

Glow plugs or an intake air heater warm the combustion air for cold starts. The engine speed sensor and the crankshaft and camshaft sensors tell the controller and the engine ECU how fast the engine turns and where the pistons are. The unit can run the engine at low or high speed.

FaultStop07Thermo King · Engine starting, glow plugs and engine speed
Code shows hereFAULT07

Where this code shows

Press the alarm key or open the Alarms menu on the controller display to list active alarms.

What do these codes mean?

Thermo King codes 07 to 845 are all about the engine starting, glow plugs and engine speed. 6 need an immediate stop. Start with this check: check battery voltage and the battery cable connections before a start attempt.

How urgent are they?

6 of 23 codes here mean stop now; 8 can wait until the shift ends, but find the cause before the next one; 9 are information only.

  • Stop now6
  • Check soon8
  • Info9

What should I check first?

Check battery voltage and the battery cable connections before a start attempt

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Thermo King 07Check engine RPM sensor

    The controller is not getting a valid speed signal from the engine RPM sensor, usually a magnetic pickup at the flywheel, so it cannot tell whether the engine is running or at what speed.· Other
    Stop now

    Causes

    • Magnetic pickup gap wrong or sensor loose in the bell housing
    • Pickup coil open or wiring broken
    • Metal debris on the pickup tip
    • Connector pins corroded on the engine harness

    Checks

    1. 1Check the pickup is seated and the tip is clean and free of metal swarf
    2. 2Measure the pickup coil resistance and compare to the manual
    3. 3Check the harness continuity to the controller and look for ground shorts
    4. 4Crank the engine while monitoring the RPM reading on the controller
    5. 5Check flywheel teeth for damage that could weaken the signal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 15Check glow plugs or intake air heater

    The glow plug or intake heater circuit shows a fault during pre-heat.· Other
    Check soon

    Causes

    • Glow plug burned out
    • Glow plug relay or fusible link failed
    • Wiring to the plugs corroded or loose
    • Intake air heater element open

    Checks

    1. 1Check the glow plug fuse or fusible link before anything else
    2. 2Measure voltage at the glow plug bus bar during pre-heat
    3. 3Check each glow plug resistance with the harness removed
    4. 4Test the glow plug relay output while pre-heat is commanded
    5. 5Inspect the heavy battery-feed wiring for corroded lugs
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 16Manual start not completed

    The unit was put in manual start mode but the start sequence was not finished within the allowed time.· Other
    Info

    Causes

    • Operator did not press the start key again after pre-heat
    • Start key or panel button stuck or worn
    • Start sequence interrupted by another alarm

    Checks

    1. 1Repeat the manual start and follow the prompts exactly
    2. 2Check the start button or key switch contacts for wear or sticking
    3. 3Look for other active alarms that block the start
    4. 4Check battery voltage under load during the attempt
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 17Engine failed to crank

    The controller commanded the starter but the engine did not turn over.· Other
    Stop now

    Causes

    • Weak or discharged battery
    • Corroded battery terminals or ground strap
    • Starter solenoid or starter motor failed
    • Starter relay not receiving a start command

    Checks

    1. 1Measure battery voltage at rest and while a start is attempted
    2. 2Clean and tighten the battery terminals and the engine ground
    3. 3Check the starter relay clicks when start is commanded
    4. 4Test voltage at the starter solenoid terminal during cranking
    5. 5Rule out a mechanical lock-up by turning the engine by hand
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 20Engine failed to start

    The engine cranked for the full attempt time but never fired and held RPM.· Other
    Stop now

    Causes

    • Out of fuel or fuel valve closed
    • Air in the fuel lines or clogged filter
    • Fuel solenoid not energised
    • Cold weather with failed glow plugs
    • Low battery cranking too slowly

    Checks

    1. 1Check the fuel tank level and the shutoff valve position
    2. 2Bleed the fuel system and replace the filter if it is dirty
    3. 3Check the fuel solenoid pulls in when run is commanded
    4. 4Check the glow plugs work, mainly in cold weather
    5. 5Listen to the cranking speed and test the battery under load
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 33Check engine RPM

    The measured engine speed does not match the speed the controller asked for, high or low, outside the allowed margin.· Other
    Check soon

    Causes

    • Speed actuator or throttle linkage sticking
    • Fuel supply restricted
    • RPM sensor reading wrong

    Checks

    1. 1Watch the displayed RPM during a speed change and note the error
    2. 2Check the speed solenoid or actuator moves freely
    3. 3Replace the fuel filter and check for air in the lines
    4. 4Check the RPM sensor signal at the controller
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 40Check high speed circuit

    The controller found a fault in the circuit that selects high engine speed, so the unit may be stuck in low speed.· Other
    Check soon

    Causes

    • Speed solenoid coil open or shorted
    • High speed relay failed
    • Wiring loose at the governor solenoid

    Checks

    1. 1Command high speed in a test and check the solenoid moves
    2. 2Measure the solenoid coil resistance with the plug off
    3. 3Check relay and fuse for the high speed circuit
    4. 4Inspect the speed solenoid plug and wiring for loose, spread or corroded pins
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 42Unit forced to low speed

    The controller has locked the unit into low engine speed, usually to protect it from another fault.· Other
    Check soon

    Causes

    • Another active alarm forcing the limit
    • Speed solenoid fault
    • Overheating or high pressure protection

    Checks

    1. 1Read the other active alarms and clear them first
    2. 2Check coolant temperature and discharge pressure
    3. 3Test that the speed solenoid pulls in when commanded
    4. 4Clear the alarms and retest both speeds to confirm the unit now reaches high speed
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 43Unit forced to low speed modulation

    The unit has been forced to low speed with modulation, a reduced-capacity protection mode used when another system limit has been reached.· Other
    Check soon

    Causes

    • High compressor temperature or pressure protection active
    • Modulation valve fault
    • Engine overload

    Checks

    1. 1Check for high temperature or pressure alarms alongside
    2. 2Check the modulation valve circuit and its coil for the fault that forces this mode
    3. 3Clean the condenser coil of dirt, since high load often triggers this limit
    4. 4Clear the alarm and observe the speeds and capacity over a full cooling cycle
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 55Check engine speeds

    The engine speeds for low and high do not match the setpoints, indicating governor or speed control trouble.· Other
    Check soon

    Causes

    • Throttle or speed linkage out of adjustment
    • Speed solenoid weak
    • Fuel filter blocked

    Checks

    1. 1Measure engine speed in low and high with a tachometer
    2. 2Adjust the speed linkage and stops per the manual until both speeds are correct
    3. 3Check the speed solenoid for a weak pull, that fails to move the lever fully
    4. 4Replace the fuel filters, since a restricted flow can stop the engine reaching speed
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 511Engine wait to start time delay expired

    The delay before an engine start attempt has run out.· Other
    Info

    Causes

    • Start delay timer finished
    • Several starts attempted close together

    Checks

    1. 1Check whether the unit started normally afterwards
    2. 2Clear the alarm and restart if the unit is still off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 600Check crankshaft speed sensor

    The engine ECU is not getting a usable crankshaft speed signal, so it cannot time the injection or know the engine speed.· Other
    Stop now

    Causes

    • Crankshaft sensor connector loose or corroded
    • Sensor wire chafed against the block
    • Sensor gap wrong or tip contaminated
    • Damaged trigger wheel

    Checks

    1. 1Inspect the crankshaft sensor plug and wires for chafing near the block
    2. 2Measure the sensor resistance and compare with the engine manual
    3. 3Check the sensor is seated and its tip is clean
    4. 4Look at the trigger wheel for missing or damaged teeth
    5. 5Read the ECU data for engine speed while cranking
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 601Check camshaft speed sensor

    The engine ECU is not receiving a valid camshaft position signal, which it uses to tell which cylinder is on compression.· Other
    Check soon

    Causes

    • Camshaft sensor wiring damaged
    • Connector corroded
    • Sensor failed or loose in its bore
    • Timing gear or reluctor problem

    Checks

    1. 1Inspect the camshaft sensor connector and its wires for damage
    2. 2Check the sensor is fully seated and its mounting bolt is tight
    3. 3Measure the sensor resistance or signal against the manual
    4. 4Compare the cam signal with the crank signal in the ECU data
    5. 5Check the engine timing if signals are present but out of step
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 611Check glow plug circuit

    The engine ECU found a fault in the glow plug circuit, which is its own control of the pre-heat rather than the unit controller.· Other
    Check soon

    Causes

    • Burnt glow plug
    • Glow plug relay or its driver failed
    • Corroded glow plug supply cable
    • Open fuse

    Checks

    1. 1Check the glow plug fuse and supply cable for corrosion
    2. 2Measure resistance of each plug with the supply lead removed
    3. 3Listen for the glow relay clicking during pre-heat
    4. 4Check the ECU output command in the data list
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 620No RPM detected during start attempt

    While cranking, the engine ECU never saw an engine speed signal, so it will not allow the injection to start.· Other
    Stop now

    Causes

    • Speed sensor not producing a signal
    • Sensor wiring open
    • Starter cranking too slowly

    Checks

    1. 1Check the speed sensor wiring and connector for breaks while cranking
    2. 2Check the battery voltage during cranking to rule out a slow crank
    3. 3Look at the live engine speed value while cranking for any signal
    4. 4Check the sensor air gap and the tone wheel it reads
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 642ECU forced low speed

    The engine ECU forced the engine to low speed, usually to protect it.· Other
    Info

    Causes

    • Engine protection limit reached
    • Sensor fault

    Checks

    1. 1Look for other engine alarms
    2. 2Check coolant and oil
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 800Crankshaft position sensor error

    The crankshaft position sensor reports an error.· Other
    Info

    Causes

    • Sensor wire damaged
    • Gap wrong

    Checks

    1. 1Check the sensor plug and gap
    2. 2Measure the sensor resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 801Camshaft position sensor error

    The camshaft position sensor reports an error.· Other
    Info

    Causes

    • Sensor wire damaged
    • Gap wrong

    Checks

    1. 1Check the sensor plug and gap
    2. 2Measure the sensor resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 811Glow plug circuit error

    The glow plug circuit reports an error.· Other
    Info

    Causes

    • Open glow plug or wiring
    • Relay fault

    Checks

    1. 1Check the glow plugs and relay
    2. 2Measure the glow plug current
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 839Engine speed error

    The engine ECU reports an error in the engine speed signal.· Other
    Info

    Causes

    • Speed sensor wiring damaged
    • Sensor gap wrong

    Checks

    1. 1Check the speed sensor plug and wiring
    2. 2Compare the speed on the display with a tachometer
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 842Engine running in safe mode - Low speed

    The engine runs in a safe mode limited to low speed.· Other
    Info

    Causes

    • ECU found a serious fault
    • Sensor fault

    Checks

    1. 1Read the stored ECU codes with the service tool
    2. 2Check coolant and oil
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 844Engine failed to crank (engine ECU)

    The engine ECU commanded cranking but the engine did not turn over, which is its own version of the failed-to-crank condition.· Other
    Stop now

    Causes

    • Weak battery
    • Starter relay failed
    • Starter motor failed
    • Corroded cable

    Checks

    1. 1Measure battery voltage at rest and during cranking
    2. 2Check the starter relay and its fuse for a click and continuity
    3. 3Check the starter cables and the ground strap for voltage drop
    4. 4Check the starter motor draws current when powered directly
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 845Starter relay error

    The starter relay circuit reports a fault.· Other
    Info

    Causes

    • Starter relay or its socket faulty
    • Wiring fault to the starter

    Checks

    1. 1Swap the starter relay with a known good one
    2. 2Check the starter wiring and battery cable
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Check battery voltage and the battery cable connections before a start attempt
  2. 2Measure the current drawn by the glow plugs or the heater when energised
  3. 3Check the sensor mounting bolt and the gap between the sensor and the pulse wheel
  4. 4Check the high speed circuit with a meter for supply and ground at the solenoid
  5. 5Listen for the starter relay and the starter when a start is attempted
  6. 6Check the glow relay and its fuse in the unit electrical box
  7. 7Inspect the wiring and plug for chafing, oil and corrosion

Causes

  • Weak battery or loose battery cables
  • Burnt-out glow plug or heater element
  • Sensor gap wrong or loose mounting
  • High speed solenoid or its wiring faulty

When to stop

You'll notice: The unit does not start or has to be started manually, with the alarm number on the display.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.