John Deere · Main controller (MCZ) - attachment levers
John Deere Auxiliary function lever (AFL) outputs, sensors and levers fault codes
The auxiliary function lever system runs hydraulic attachments. OPT 1 (1A, Y61) and OPT 2 (1B, Y62) drive the two directions of the attachment spool, and OPT 3 and OPT 4 are extra outputs.
More about these partsLess
Electric lever operating pressure sensors 1 (B85, PS1) and 2 report lever demand. The right (S29) and left analog stroke sensors give proportional control from each joystick, and optional electric levers 1 and 2 enable attachment functions through the PiC pilot shutoff solenoid (Y66).
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes MCZ 11810.03 to MCZ 15017.04 are all about the auxiliary function lever (AFL) outputs, sensors and levers. The most common failure type is real condition (8 of 24); none needs an immediate stop. Start with this check: find which part the code names (OPT output, pressure sensor, analog stroke sensor or lever) and test only that one.
How urgent are they?
None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.
- Check soon24
What should I check first?
Find which part the code names (OPT output, pressure sensor, analog stroke sensor or lever) and test only that one
Shared checks24 of 24
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere MCZ 11810.03Electric lever operating pressure sensor 1 high voltage
The controller reads the electric lever operating pressure sensor 1 (B85, PS1) signal above its normal range (the list gives above 4.5 V), so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted highShorted highCheck soonCauses
- Signal wire of the electric lever operating pressure sensor 1 (B85, PS1) shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the electric lever operating pressure sensor 1 (B85, PS1), which lets the signal float high
- The electric lever operating pressure sensor 1 (B85, PS1) failed internally with a stuck high output
Checks
- 1Unplug the electric lever operating pressure sensor 1 (B85, PS1) and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the electric lever operating pressure sensor 1 (B85, PS1) return wire to the controller sensor ground with both ends disconnected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11810.04Electric lever operating pressure sensor 1 low voltage
The controller reads the electric lever operating pressure sensor 1 (B85, PS1) signal below its normal range (the list gives below 0.1 V), so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the electric lever operating pressure sensor 1 (B85, PS1) shorted to ground
- Broken or unplugged 5 V supply wire to the electric lever operating pressure sensor 1 (B85, PS1)
- The electric lever operating pressure sensor 1 (B85, PS1) failed internally with a stuck low output
Checks
- 1With the electric lever operating pressure sensor 1 (B85, PS1) unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere MCZ 11811.03Electric lever operating pressure sensor 2 high voltage
The controller reads the electric lever operating pressure sensor 2 signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted highShorted highCheck soonCauses
- Signal wire of the electric lever operating pressure sensor 2 shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the electric lever operating pressure sensor 2, which lets the signal float high
- The electric lever operating pressure sensor 2 failed internally with a stuck high output
Checks
- 1Unplug the electric lever operating pressure sensor 2 and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the electric lever operating pressure sensor 2 return wire to the controller sensor ground with both ends disconnected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11811.04Electric lever operating pressure sensor 2 low voltage
The controller reads the electric lever operating pressure sensor 2 signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the electric lever operating pressure sensor 2 shorted to ground
- Broken or unplugged 5 V supply wire to the electric lever operating pressure sensor 2
- The electric lever operating pressure sensor 2 failed internally with a stuck low output
Checks
- 1With the electric lever operating pressure sensor 2 unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere MCZ 11812.02Optional electric lever 1 neutral abnormal
The first optional (auxiliary) electric lever reports a non-neutral signal at rest. The PiC solenoid (Y66) signal is about 0.1 V or less.· OtherOtherCheck soonCauses
- Optional lever not centring back to neutral
- Lever potentiometer out of range
- Wiring fault in the lever signal circuit
Checks
- 1Check the lever centres mechanically and moves freely without binding
- 2Read the lever signal on the monitor service screen at rest
- 3Unplug the lever and check its supply and signal voltages
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11813.02Optional electric lever 1 abnormal operation
The first optional auxiliary electric lever shows an abnormal current in its PiC proportional solenoid circuit. The operator finds the attachment (breaker, tilt, rotator) slow, jerky or not responding to the lever.· Part or controllerPart or controllerCheck soonCauses
- Coil of the PiC solenoid failing
- Chafed solenoid wires
- Poor connector contact
Checks
- 1Measure the PiC solenoid coil resistance with the plug removed
- 2Check the solenoid wiring for continuity and shorts to ground
- 3Wiggle the connector with the machine running and watch the current
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
John Deere MCZ 11814.02OPT electric lever 2 neutral abnormal
The second optional electric lever does not show a clean neutral signal to the main controller, so the controller cannot confirm the lever is released.· OtherOtherCheck soonCauses
- Intermittent connection at the optional electric lever 2 plug or in its harness
- Chafed wire that touches ground only when the machine moves
- The optional electric lever 2 wearing out or failing intermittently
Checks
- 1Wiggle the optional electric lever 2 harness and plug with the key on while watching the live value for jumps or dropouts
- 2Compare the live reading with the machine state (stopped, idling, working) to see when it goes wrong
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11815.02OPT electric lever 2 abnormal operation
The controller sees an abnormal signal while optional electric lever 2 is used, so the attachment function it controls does not behave as the operator commands.· OtherOtherCheck soonCauses
- Intermittent connection at the optional electric lever 2 plug or in its harness
- Chafed wire that touches ground only when the machine moves
- The optional electric lever 2 wearing out or failing intermittently
Checks
- 1Wiggle the optional electric lever 2 harness and plug with the key on while watching the live value for jumps or dropouts
- 2Compare the live reading with the machine state (stopped, idling, working) to see when it goes wrong
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11816.02OPT solenoid 1 feedback abnormal
The current feedback of the auxiliary function lever (AFL) solenoid A (1A, Y61) is abnormal: the controller sees the drive current leaving its allowed band (the list gives above 920 mA and below 70 mA as the limits), so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the auxiliary function lever (AFL) solenoid A (1A, Y61)
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the auxiliary function lever (AFL) solenoid A (1A, Y61) coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11816.03OPT solenoid 1 feedback current high
The feedback current of the auxiliary function lever (AFL) solenoid A (1A, Y61) is too high (the list gives above 920 mA), so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the auxiliary function lever (AFL) solenoid A (1A, Y61) coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the auxiliary function lever (AFL) solenoid A (1A, Y61) coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11816.04OPT solenoid 1 feedback current low
The feedback current of the auxiliary function lever (AFL) solenoid A (1A, Y61) is too low (the list gives below 56 mA), so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the auxiliary function lever (AFL) solenoid A (1A, Y61)
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the auxiliary function lever (AFL) solenoid A (1A, Y61) coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11817.02OPT solenoid 2 feedback abnormal
The current feedback of the auxiliary function lever (AFL) solenoid B (1B, Y62) is abnormal: the controller sees the drive current leaving its allowed band (the list gives above 920 mA and below 70 mA as the limits), so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the auxiliary function lever (AFL) solenoid B (1B, Y62)
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the auxiliary function lever (AFL) solenoid B (1B, Y62) coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11817.03OPT solenoid 2 feedback current high
The feedback current of the auxiliary function lever (AFL) solenoid B (1B, Y62) is too high (the list gives above 920 mA), so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the auxiliary function lever (AFL) solenoid B (1B, Y62) coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the auxiliary function lever (AFL) solenoid B (1B, Y62) coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11817.04OPT solenoid 2 feedback current low
The feedback current of the auxiliary function lever (AFL) solenoid B (1B, Y62) is too low (the list gives below 56 mA), so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the auxiliary function lever (AFL) solenoid B (1B, Y62)
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the auxiliary function lever (AFL) solenoid B (1B, Y62) coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11818.02OPT solenoid 3 feedback abnormal
The current feedback of the optional (OPT) solenoid 3 is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the optional (OPT) solenoid 3
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the optional (OPT) solenoid 3 coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11818.03OPT solenoid 3 feedback current high
The feedback current of the optional (OPT) solenoid 3 is too high, so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the optional (OPT) solenoid 3 coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the optional (OPT) solenoid 3 coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11818.04OPT solenoid 3 feedback current low
The feedback current of the optional (OPT) solenoid 3 is too low, so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the optional (OPT) solenoid 3
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the optional (OPT) solenoid 3 coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11819.02OPT solenoid 4 feedback abnormal
The current feedback of the optional (OPT) solenoid 4 is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the optional (OPT) solenoid 4
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the optional (OPT) solenoid 4 coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11819.03OPT solenoid 4 feedback current high
The feedback current of the optional (OPT) solenoid 4 is too high, so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the optional (OPT) solenoid 4 coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the optional (OPT) solenoid 4 coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11819.04OPT solenoid 4 feedback current low
The feedback current of the optional (OPT) solenoid 4 is too low, so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the optional (OPT) solenoid 4
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the optional (OPT) solenoid 4 coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 15016.03Right analog stroke sensor circuit high input
The controller reads the right analog stroke sensor (S29 proportional control switch) signal above its normal range (the list gives above 4.5 V), so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· OtherOtherCheck soonCauses
- Signal wire of the right analog stroke sensor (S29 proportional control switch) shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the right analog stroke sensor (S29 proportional control switch), which lets the signal float high
- The right analog stroke sensor (S29 proportional control switch) failed internally with a stuck high output
Checks
- 1Unplug the right analog stroke sensor (S29 proportional control switch) and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the right analog stroke sensor (S29 proportional control switch) return wire to the controller sensor ground with both ends disconnected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 15016.04Right analog stroke sensor circuit low input
The controller reads the right analog stroke sensor (S29 proportional control switch) signal below its normal range (the list gives below 0.1 V), so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· OtherOtherCheck soonCauses
- Signal wire of the right analog stroke sensor (S29 proportional control switch) shorted to ground
- Broken or unplugged 5 V supply wire to the right analog stroke sensor (S29 proportional control switch)
- The right analog stroke sensor (S29 proportional control switch) failed internally with a stuck low output
Checks
- 1With the right analog stroke sensor (S29 proportional control switch) unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 15017.03Left analog stroke sensor circuit high input
The controller reads the left analog stroke sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· OtherOtherCheck soonCauses
- Signal wire of the left analog stroke sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the left analog stroke sensor, which lets the signal float high
- The left analog stroke sensor failed internally with a stuck high output
Checks
- 1Unplug the left analog stroke sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the left analog stroke sensor return wire to the controller sensor ground with both ends disconnected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 15017.04Left analog stroke sensor circuit low input
The controller reads the left analog stroke sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· OtherOtherCheck soonCauses
- Signal wire of the left analog stroke sensor shorted to ground
- Broken or unplugged 5 V supply wire to the left analog stroke sensor
- The left analog stroke sensor failed internally with a stuck low output
Checks
- 1With the left analog stroke sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Find which part the code names (OPT output, pressure sensor, analog stroke sensor or lever) and test only that one
- 2For OPT outputs measure the coil resistance and read commanded against fed-back current while using the tool
- 3For sensors and stroke switches measure the signal pin for a short to the feed (near 5 V) or ground (near 0 V)
- 4Read the live stroke or pressure value while moving the lever slowly; it should change smoothly, not jump or sit at one value
- 5Check the joystick and valve connectors for water, oil and bent pins, and flex the cable at the boot while watching the value
Causes
- Solenoid coil open or with shorted turns
- Wire broken or chafed along the boom or in the joystick boot cable
- Sensor or lever switch failed, giving a fixed voltage
- Connector wet or corroded at the valve or under the armrest
Most common here: real condition (8 of 24)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: The attachment function does not work, runs at the wrong speed, loses proportional control or stays on, depending on which output, sensor or lever the code names.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.