JCB Fault Code P203F‑68
DEF tank level low
What does JCB code P203F-68 mean?
The DEF level is below the warning limit. Running on will lead to inducement and a power derate. Urgency: check soon - the machine may derate or limit a function. Check first: look at the DEF tank and add the correct DEF to the filler neck.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Look at the DEF tank and add the correct DEF to the filler neck
Then 5 more checksWhere this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
Checks
0 of 6 done
Causes
- DEF tank genuinely running low
- DEF level sensor reading low in error
- Fluid not topped up after the earlier low warning
- Leak from the tank, line or pump module
1 more causeFewer causes
- Sensor connector fault giving a false low level
How it failed
You'll notice: The operator sees a DEF low lamp and a message on the display.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: DEF tank level and DEF tank temperature
- P203B-15DEF tank level signal exceeds maximum voltage limitShorted highCheck soon
- P203B-16DEF tank level plausibility errorErratic or implausibleCheck soon
- P203F-21DEF tank head unit level signal below minimum limitOtherCheck soon
- P203B-22DEF tank level signal above maximum limitOpen circuitCheck soon
- P203F-68DEF tank level lowOtherCheck soon
- P203B-81CAN bus message error from head unit (tank level)Lost messageCheck soon
- P203B-86CAN bus error for DEF tank levelLost messageCheck soon
- P203B-87CAN bus off error from head unit (tank level)Lost messageCheck soon
- P205B-00DEF tank overheatingReal conditionCheck soon
Show the other 18 codesHide the other codes
- P203B-00DEF tank level signal errorErratic or implausibleCheck soon
- P203F-7BDEF tank emptyReal conditionStop now
- P203B-14DEF tank level signal below minimum voltageShorted lowCheck soon
- P205B-06DEF tank temperature increase errorLost messageCheck soon
- P205B-16DEF tank temperature signal below minimumShorted lowCheck soon
- P205C-16DEF tank temperature signal voltage below minimum limitOtherCheck soon
- P205B-17DEF tank head unit temperature signal above maximum limitOpen circuitCheck soon
- P205D-17DEF tank temperature signal voltage above maximum limitShorted highCheck soon
- P205B-23DEF tank temperature sensor plausibility below minimumErratic or implausibleCheck soon
- P205B-24DEF tank temperature sensor plausibility above maximumErratic or implausibleCheck soon
- P205E-81DEF tank temperature signal error on CANLost messageCheck soon
- P205E-87CAN bus message error for DEF tank temperature from head unitLost messageCheck soon
- P2043-81CAN bus message error from head unit (DEF temperature)Lost messageCheck soon
- P2043-86DEF temperature message error from head unitLost messageCheck soon
- P2043-87CAN bus off error from head unit (DEF temperature)Lost messageCheck soon
- P3411-87Critically low DEF level detectedOtherCheck soon
- P3412-87DEF tank sensor open circuitOpen circuitCheck soon
- P3413-87DEF tank sensor short circuitShort circuitCheck soon
Other JCB codes: Aftertreatment ECU - SCR / DEF
Related on Equipments Finder
Source
Partao JCB fault code list, page 10 (code table)
This source lists P203F-68 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Tier 4 Final / Stage V machines with SCR.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.