JCB Pressure transducers, hydraulic oil temperature, cooling fan and controls enable fault codes

The pump and pilot pressure transducers read hydraulic pressure for the controller so it can match the operator's movements. The hydraulic oil temperature sensor warns of hot oil.

More about these parts

It is monitored by the controller for the hydraulic oil temperature sensor. The cooling fan solenoid on the hydraulic fan drive sets how fast the fan turns according to coolant and oil temperature. If it fails, the fan usually goes to full speed or stops, depending on the valve. The controls enable circuit stops hydraulic movement unless the operator enables it, and the lever lock switches confirm the lock state.

FaultCheckC1023JCB · Pressure transducers, hydraulic oil temperature, cooling fan and controls enable
Code shows hereFAULTC1023

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes C031E to C1318 are all about the pressure transducers, hydraulic oil temperature, cooling fan and controls enable. The most common failure type is open circuit (7 of 22); 1 needs an immediate stop. Start with this check: measure the supply voltage at the pressure transducer plug with the key on.

How urgent are they?

1 of 22 codes here means stop now; the other 21 can wait until the shift ends, but find the cause before the next one.

  • Stop now1
  • Check soon21

What should I check first?

Measure the supply voltage at the pressure transducer plug with the key on

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB C031ELow flow pressure transducer output out of range low

    The low flow pressure transducer output is below its allowed range.· Shorted low
    Check soon

    Causes

    • Low flow pressure transducer signal wire shorted to ground
    • Low flow pressure transducer failed with its output stuck low

    Checks

    1. 1Unplug the low flow pressure transducer and check the signal wire for a short to ground
    2. 2Compare the low flow pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C031FLow flow pressure transducer output out of range high

    The low flow pressure transducer output is above its allowed range.· Open circuit
    Check soon

    Causes

    • Low flow pressure transducer signal wire shorted to its 5 V supply
    • Low flow pressure transducer failed with its output stuck high

    Checks

    1. 1Check the 5 V reference at the low flow pressure transducer plug, then the signal voltage with the engine off
    2. 2Compare the low flow pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C102BCooling fan solenoid fault condition

    Cooling fan solenoid fault condition.· Other
    Check soon

    Causes

    • Cooling fan solenoid fault condition or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the cooling fan solenoid fault condition and look for a value that is stuck or implausible
    2. 2Check the cooling fan solenoid fault condition connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB C102CCooling fan solenoid short circuit

    The controller found the cooling fan solenoid output shorted, drawing too much current or sitting at ground or supply, and it switched the output off to protect itself.· Lost message
    Check soon

    Causes

    • Cooling fan proportional solenoid shorted
    • Fan solenoid wire chafed against the fan shroud or radiator frame
    • Water in the fan solenoid plug

    Checks

    1. 1Measure the fan solenoid coil resistance and look for a very low reading
    2. 2Test the solenoid wires for a short to ground with the connector unplugged
    3. 3Check the harness near the fan shroud for rubbing and heat damage
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB C102DCooling fan solenoid open circuit

    The controller sees no current through the cooling fan solenoid output, so the circuit is open.· Open circuit
    Check soon

    Causes

    • Cooling fan solenoid coil open
    • Broken wire or loose pin in the fan solenoid plug
    • Wiring pulled or snapped at the engine bay

    Checks

    1. 1Measure the fan solenoid coil resistance across its two pins
    2. 2Check continuity of both wires from the solenoid plug back to the controller
    3. 3Inspect the plug for corrosion and backed-out pins
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C131ALever lock switches plausibility error

    Lever lock switches plausibility error.· Erratic or implausible
    Check soon

    Causes

    • Lever lock switches plausibility drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the lever lock switches plausibility circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the lever lock switches plausibility value on live data with a known good value or a reference gauge
    2. 2Check the lever lock switches plausibility connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB C0320High flow pressure transducer output below range

    The high flow pressure transducer output is below its allowed range.· Shorted low
    Check soon

    Causes

    • High flow pressure transducer signal wire shorted to ground
    • High flow pressure transducer failed with its output stuck low

    Checks

    1. 1Unplug the high flow pressure transducer and check the signal wire for a short to ground
    2. 2Compare the high flow pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C0321High flow pressure transducer output out of range high

    The high flow pressure transducer output is above its allowed range.· Open circuit
    Check soon

    Causes

    • High flow pressure transducer signal wire shorted to its 5 V supply
    • High flow pressure transducer failed with its output stuck high

    Checks

    1. 1Check the 5 V reference at the high flow pressure transducer plug, then the signal voltage with the engine off
    2. 2Compare the high flow pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C0322Low flow pilot pressure transducer output out of range low

    The low flow pilot pressure transducer output is below its allowed range.· Shorted low
    Check soon

    Causes

    • Low flow pilot pressure transducer signal wire shorted to ground
    • Low flow pilot pressure transducer failed with its output stuck low

    Checks

    1. 1Unplug the low flow pilot pressure transducer and check the signal wire for a short to ground
    2. 2Compare the low flow pilot pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C0323Low flow pilot pressure transducer output out of range high

    The low flow pilot pressure transducer output is above its allowed range.· Open circuit
    Check soon

    Causes

    • Low flow pilot pressure transducer signal wire shorted to its 5 V supply
    • Low flow pilot pressure transducer failed with its output stuck high

    Checks

    1. 1Check the 5 V reference at the low flow pilot pressure transducer plug, then the signal voltage with the engine off
    2. 2Compare the low flow pilot pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C0324High flow pilot pressure transducer output low

    The high flow pilot pressure transducer output is below its allowed range.· Shorted low
    Check soon

    Causes

    • High flow pilot pressure transducer signal wire shorted to ground
    • High flow pilot pressure transducer failed with its output stuck low

    Checks

    1. 1Unplug the high flow pilot pressure transducer and check the signal wire for a short to ground
    2. 2Compare the high flow pilot pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C0325High flow pilot pressure transducer output out of range high

    The high flow pilot pressure transducer output is above its allowed range.· Open circuit
    Check soon

    Causes

    • High flow pilot pressure transducer signal wire shorted to its 5 V supply
    • High flow pilot pressure transducer failed with its output stuck high

    Checks

    1. 1Check the 5 V reference at the high flow pilot pressure transducer plug, then the signal voltage with the engine off
    2. 2Compare the high flow pilot pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1023Hydraulic oil temperature high alarm

    Hydraulic oil temperature has gone above the alarm limit.· Other
    Check soon

    Causes

    • Hydraulic oil cooler blocked with dirt on the outside, or the fan not running
    • Low hydraulic oil level or the wrong oil grade
    • Hydraulic relief valve opening continuously from a worn pump or spool
    • Work cycle holding the machine against the relief, for example stalled attachments
    • Temperature sender reading high

    Checks

    1. 1Check hydraulic oil level and condition, and look for foaming or a burnt smell
    2. 2Clean the oil cooler core and check the cooling fan runs when warm
    3. 3Check the temperature with an infrared thermometer on the tank and compare it with the display
    4. 4Check whether the high temperature occurs only while an attachment is working against relief
    5. 5Test the system pressure with a gauge at a test point
    6. 6Check the sensor wiring and read live temperature in the diagnostic tool
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB C1024Hydraulic oil temperature sensor open circuit

    The hydraulic oil temperature sensor circuit is open, so the controller reads no valid temperature.· Open circuit
    Check soon

    Causes

    • Hydraulic oil temperature sensor open circuit
    • Sensor unplugged or pins corroded
    • Broken wire in the sensor harness at the tank

    Checks

    1. 1Read the oil temperature live and see if it is stuck at the minimum value
    2. 2Check the sensor plug is fitted and the pins are clean
    3. 3Measure sensor resistance and see if it reads open
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1032Hydraulic oil temperature critical alarm

    Hydraulic oil temperature has reached the critical limit.· Real condition
    Stop now

    Causes

    • Hydraulic oil cooler or fan not working during a long hard work cycle
    • Very low oil level so the same oil is overworked
    • Pump or valve internal leakage generating heat

    Checks

    1. 1Stop the machine, let it idle and watch the temperature fall
    2. 2Check oil level in the sight glass and inspect the oil for burning
    3. 3Check the hydraulic cooler for blockage and the fan for correct speed
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB C1035Hydraulic oil temperature sensor short circuit

    The hydraulic oil temperature sensor circuit is shorted, so the controller reads an impossible temperature.· Short circuit
    Check soon

    Causes

    • Hydraulic oil temperature sensor signal shorted to ground
    • Sensor internally shorted
    • Water in the sensor plug at the tank

    Checks

    1. 1Read the oil temperature live and see if it shows an extreme high value
    2. 2Unplug the sensor and see whether the reading changes to the opposite extreme
    3. 3Measure the sensor resistance and see if it is close to zero
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB B1302Controls enable switch fault

    Controls enable switch fault.· Other
    Check soon

    Causes

    • Controls enable switch or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the controls enable switch and look for a value that is stuck or implausible
    2. 2Check the controls enable switch connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB C1307Controls enable solenoid open circuit

    The controller sees no current through the controls enable solenoid output, so the circuit is open.· Open circuit
    Check soon

    Causes

    • Controls enable solenoid coil open
    • Broken wire or backed-out pin in the controls enable connector
    • Wiring broken where it is clamped near the pilot manifold or in the cab loom

    Checks

    1. 1Measure the controls enable solenoid coil resistance with the plug removed
    2. 2Check continuity of the supply and return wires back to the controller
    3. 3Check the lever lock or armrest switch moves and sends a signal to the controller
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1308Controls enable solenoid short circuit

    The controller found the controls enable solenoid output shorted, drawing too much current or sitting at ground or supply, and it switched the output off to protect itself.· Short circuit
    Check soon

    Causes

    • Controls enable solenoid coil shorted or drawing too much current
    • Solenoid wire chafed against the pilot manifold or bracket and touching ground
    • Water in the solenoid plug causing a short between pins

    Checks

    1. 1Measure the coil resistance and look for a reading much lower than the other solenoids
    2. 2Test both solenoid wires for a short to ground with the connector unplugged
    3. 3Check the pilot manifold area for rubbed wires and damaged conduit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C1316Pilot pressure transducer voltage above normal

    The pilot pressure transducer output is above its allowed range.· Shorted high
    Check soon

    Causes

    • Pilot pressure transducer signal wire shorted to its 5 V supply
    • Pilot pressure transducer failed with its output stuck high

    Checks

    1. 1Check the 5 V reference at the pilot pressure transducer plug, then the signal voltage with the engine off
    2. 2Compare the pilot pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB C1317Pilot pressure transducer voltage below normal

    The pilot pressure transducer output is below its allowed range.· Shorted low
    Check soon

    Causes

    • Pilot pressure transducer signal wire shorted to ground
    • Pilot pressure transducer failed with its output stuck low

    Checks

    1. 1Unplug the pilot pressure transducer and check the signal wire for a short to ground
    2. 2Compare the pilot pressure transducer reading with a test gauge at the same port
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C1318Controls enable pressure out of range

    Controls enable pressure out of range.· Erratic or implausible
    Check soon

    Causes

    • Controls enable pressure out of range drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the controls enable pressure out of range circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the controls enable pressure out of range value on live data with a known good value or a reference gauge
    2. 2Check the controls enable pressure out of range connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

Shared checks

Checks, in order

  1. 1Measure the supply voltage at the pressure transducer plug with the key on
  2. 2Check the cooler and oil level (on the hydraulic oil temperature sensor, with the diagnostic tool and a multimeter)
  3. 3Measure the fan solenoid coil resistance at the plug and compare it with the manual value
  4. 4Check the switch and solenoid (on the controls enable circuit, with the diagnostic tool and a multimeter)
  5. 5Check the wiring to the pressure transducer for opens, shorts to ground or battery, and chafing
  6. 6Compare the hydraulic oil temperature sensor reading on live data with a known good value
  7. 7Check the harness near the fan shroud for rubbing and heat damage

Causes

  • Transducer failed
  • Oil too hot
  • Fan drive solenoid coil failed
  • Switch or solenoid failed

Most common here: open circuit (7 of 22)

Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

When to stop

You'll notice: Controls may respond poorly.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.