JCB · Hydraulic controller (HECU)
JCB Main flow solenoids fault codes
The hydraulic controller drives low flow, high flow, merge flow and ARV solenoids that set pump flow to each function, and the pump 1 output.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes C030C to C1336 are all about the main flow solenoids. The most common failure type is short circuit (9 of 22); none needs an immediate stop. Start with this check: measure the solenoid resistance (on the flow solenoid, with the diagnostic tool and a multimeter).
How urgent are they?
None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.
- Check soon22
What should I check first?
Measure the solenoid resistance (on the flow solenoid, with the diagnostic tool and a multimeter)
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB C030CMerge flow A solenoid short circuit
The hydraulic controller found the merge flow A solenoid, which joins two pump flows together for function A, shorted or drawing too much current, and switched the output off to protect itself; function A cannot combine pump flow, so it moves slowly when a lot of oil is needed. Merge A cannot add the second pump flow.· Short circuitShort circuitCheck soonCauses
- Wire to the merge flow A solenoid chafed against the frame or the valve block
- Merge flow a solenoid coil shorted internally
- Merge A spool jammed by debris
- Merge valve seat scored by debris
Checks
- 1Unplug the merge flow A solenoid and measure the coil resistance against the manual value
- 2With the plug off, check each merge flow A wire for a short to ground
- 3Check the plug seal for hydraulic oil inside the connector
- 4Check the hydraulic filters for debris that could jam the merge A spool
- 5Operate merge A with two pump flows demanded and watch the pump 2 output
- 6Pull the merge A valve cartridge and inspect the seat
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C030DMerge flow A solenoid open circuit
The hydraulic controller sees no current path through the merge flow A solenoid, which joins two pump flows together for function A, an open circuit, so the output cannot be driven; function A cannot combine pump flow, so it moves slowly when a lot of oil is needed. Merge A cannot add the second pump flow.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin at the merge flow A solenoid plug
- Merge flow a solenoid coil burnt open
- Merge A spool jammed by debris
- Merge A coil open after a hose burst soaked the plug
Checks
- 1Measure the merge flow A solenoid coil; an open coil reads as no continuity
- 2Check the merge flow A wires for continuity from the solenoid plug to the controller
- 3Compare commanded current with measured current on the live data screen
- 4Check the hydraulic filters for debris that could jam the merge A spool
- 5Operate merge A with two pump flows demanded and watch the pump 2 output
- 6Look for signs of a past hose failure near the valve
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C030EMerge flow B solenoid short circuit
The hydraulic controller found the merge flow B solenoid, which joins two pump flows together for function B, shorted or drawing too much current, and switched the output off to protect itself; function B cannot combine pump flow, so it moves slowly under heavy demand. Merge B cannot add the second pump flow.· Short circuitShort circuitCheck soonCauses
- Wire to the merge flow B solenoid chafed against the frame or the valve block
- Merge flow b solenoid coil shorted internally
- Merge B spool jammed by debris
- Merge valve seat scored by debris
Checks
- 1Unplug the merge flow B solenoid and measure the coil resistance against the manual value
- 2With the plug off, check each merge flow B wire for a short to ground
- 3Check the pilot pressure to the valve, because low pilot pressure looks like a weak solenoid
- 4Check the hydraulic filters for debris that could jam the merge B spool
- 5Operate merge B with two pump flows demanded and watch the pump 2 output
- 6Pull the merge B valve cartridge and inspect the seat
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C030FMerge flow B solenoid open circuit
The hydraulic controller sees no current path through the merge flow B solenoid, which joins two pump flows together for function B, an open circuit, so the output cannot be driven; function B cannot combine pump flow, so it moves slowly under heavy demand. Merge B cannot add the second pump flow.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin at the merge flow B solenoid plug
- Merge flow b solenoid coil burnt open
- Merge B spool jammed by debris
- Merge B coil open after a hose burst soaked the plug
Checks
- 1Measure the merge flow B solenoid coil; an open coil reads as no continuity
- 2Check the merge flow B wires for continuity from the solenoid plug to the controller
- 3Check the continuity of both coil pins separately to ground to catch a leaky coil
- 4Check the hydraulic filters for debris that could jam the merge B spool
- 5Operate merge B with two pump flows demanded and watch the pump 2 output
- 6Look for signs of a past hose failure near the valve
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C031ALow flow A solenoid target current not achieved
The low flow A solenoid is switched on but the current does not reach its target. The coil and wiring are not open or shorted, but the current is too low, which points to high resistance or a weak supply. Low flow A is energised but weak.· Real conditionReal conditionCheck soonCauses
- High resistance in the low flow A plug or wire
- Low supply voltage reaching the solenoid driver
- Low flow A valve spool sticky from old oil
- Under-voltage from a tired battery at start-up
Checks
- 1Measure current and voltage at the low flow A solenoid while it is commanded
- 2Clean and check the low flow A connector pins
- 3Check for contamination on the solenoid spool by looking at the filter condition
- 4Cycle the low flow A function a few times and note whether it frees
- 5Run the low flow A function with a flow meter if available
- 6Check cranking voltage dip and charging voltage at the controller
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB C031BLow flow B solenoid not reaching target current or pressure
The low flow B solenoid is not reaching its target current or pressure, so the pressure it should set on the low flow B function is not achieved. Low flow B is energised but weak.· OtherOtherCheck soonCauses
- Low flow B solenoid weak or partly stuck
- High resistance in the low flow B circuit
- Hydraulic pressure supply low
- Low flow B valve spool sticky from old oil
- Pressure sensor drifting in the circuit that confirms the result
Checks
- 1Measure low flow B solenoid current while commanded
- 2Check the pilot or supply pressure to the valve
- 3Use the service tool output test to energise the solenoid and listen for the click
- 4Cycle the low flow B function a few times and note whether it frees
- 5Run the low flow B function with a flow meter if available
- 6Cross-check with a hand gauge at the test port
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB C031CHigh flow A solenoid not reaching target current or pressure
The high flow A solenoid is not reaching its target current or pressure, so the high flow A function is slow. High flow A is energised but weak.· OtherOtherCheck soonCauses
- High flow A solenoid weak or partly stuck
- High resistance in the high flow A circuit
- High flow A coil overheated from repeated hard use
- Valve spool wear letting pressure leak by
Checks
- 1Measure the high flow A solenoid current while commanded
- 2Check the supply pressure to the valve
- 3Inspect the harness clip near the valve block for chafing from vibration
- 4Feel the high flow A coil after work; a very hot or discoloured coil points to overheating
- 5Compare high flow A current with the high flow B current at the same demand
- 6Perform a pressure hold test on the valve
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB C031DHigh flow B solenoid not reaching target current or pressure
The high flow B solenoid is not reaching its target current or pressure, so the high flow B function is slow. High flow B is energised but weak.· OtherOtherCheck soonCauses
- High flow B solenoid weak or partly stuck
- High resistance in the high flow B circuit
- High flow B coil overheated from repeated hard use
- Valve spool wear letting pressure leak by
Checks
- 1Measure the high flow B solenoid current while commanded
- 2Check the supply pressure to the valve
- 3Check the earth connection of the hydraulic controller
- 4Feel the high flow B coil after work; a very hot or discoloured coil points to overheating
- 5Compare high flow B current with the high flow A current at the same demand
- 6Perform a pressure hold test on the valve
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB C0300Low flow A solenoid short circuit
The hydraulic controller found the low flow A solenoid, which sets the pump flow sent to the low flow function A, shorted or drawing too much current, and switched the output off to protect itself; the auxiliary function fed by low flow A runs weakly or not at all. The attachment on low flow A cannot get oil.· Short circuitShort circuitCheck soonCauses
- Wire to the low flow A solenoid chafed against the frame or the valve block
- Low flow a solenoid coil shorted internally
- Low flow A valve spool sticky from old oil
- Oil seepage into the solenoid plug of the low flow A valve
Checks
- 1Unplug the low flow A solenoid and measure the coil resistance against the manual value
- 2With the plug off, check each low flow A wire for a short to ground
- 3Check the valve block solenoid cartridge for a loose nut and a damaged O-ring
- 4Cycle the low flow A function a few times and note whether it frees
- 5Check that the low flow A attachment hose is connected to the right port
- 6Drain the plug of any oil and dry it with contact cleaner
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C0301Low flow A solenoid open circuit
The hydraulic controller sees no current path through the low flow A solenoid, which sets the pump flow sent to the low flow function A, an open circuit, so the output cannot be driven; the auxiliary function fed by low flow A runs weakly or not at all. The attachment on low flow A cannot get oil.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin at the low flow A solenoid plug
- Low flow a solenoid coil burnt open
- Low flow A valve spool sticky from old oil
- Vibration cracking the solder joint on the coil lead
Checks
- 1Measure the low flow A solenoid coil; an open coil reads as no continuity
- 2Check the low flow A wires for continuity from the solenoid plug to the controller
- 3Measure the supply voltage at the hydraulic controller plug while the engine runs
- 4Cycle the low flow A function a few times and note whether it frees
- 5Check that the low flow A attachment hose is connected to the right port
- 6Tug-test the coil leads gently for a hidden break
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C0302Low flow B solenoid short circuit
The hydraulic controller found the low flow B solenoid, the partner of low flow A for the second low flow function, shorted or drawing too much current, and switched the output off to protect itself; the function fed by low flow B runs weakly or not at all. The attachment on low flow B cannot get oil.· Short circuitShort circuitCheck soonCauses
- Wire to the low flow B solenoid chafed against the frame or the valve block
- Low flow b solenoid coil shorted internally
- Low flow B valve spool sticky from old oil
- Oil seepage into the solenoid plug of the low flow B valve
Checks
- 1Unplug the low flow B solenoid and measure the coil resistance against the manual value
- 2With the plug off, check each low flow B wire for a short to ground
- 3Swap the solenoid plug with a similar solenoid of the same valve block and see whether the code moves
- 4Cycle the low flow B function a few times and note whether it frees
- 5Check that the low flow B attachment hose is connected to the right port
- 6Drain the plug of any oil and dry it with contact cleaner
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C0303Low flow B solenoid open circuit
The hydraulic controller sees no current path through the low flow B solenoid, the partner of low flow A for the second low flow function, an open circuit, so the output cannot be driven; the function fed by low flow B runs weakly or not at all. The attachment on low flow B cannot get oil.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin at the low flow B solenoid plug
- Low flow b solenoid coil burnt open
- Low flow B valve spool sticky from old oil
- Vibration cracking the solder joint on the coil lead
Checks
- 1Measure the low flow B solenoid coil; an open coil reads as no continuity
- 2Check the low flow B wires for continuity from the solenoid plug to the controller
- 3Check the hydraulic oil level and temperature, since cold oil makes current faults more likely
- 4Cycle the low flow B function a few times and note whether it frees
- 5Check that the low flow B attachment hose is connected to the right port
- 6Tug-test the coil leads gently for a hidden break
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C0304High flow A solenoid short circuit
The hydraulic controller found the high flow A solenoid, which opens the larger flow path to high flow function A, shorted or drawing too much current, and switched the output off to protect itself; the high flow function A is slow or has no movement. High flow A movements are slow.· Short circuitShort circuitCheck soonCauses
- Wire to the high flow A solenoid chafed against the frame or the valve block
- High flow a solenoid coil shorted internally
- High flow A coil overheated from repeated hard use
- Overheated coil from continuous hammer or breaker work
Checks
- 1Unplug the high flow A solenoid and measure the coil resistance against the manual value
- 2With the plug off, check each high flow A wire for a short to ground
- 3Check for contamination on the solenoid spool by looking at the filter condition
- 4Feel the high flow A coil after work; a very hot or discoloured coil points to overheating
- 5Compare the high flow A cycle time with the figure in the manual
- 6Let the coil cool then retest, and note whether the code returns when hot
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C0305High flow A solenoid open circuit
The hydraulic controller sees no current path through the high flow A solenoid, which opens the larger flow path to high flow function A, an open circuit, so the output cannot be driven; the high flow function A is slow or has no movement. High flow A movements are slow.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin at the high flow A solenoid plug
- High flow a solenoid coil burnt open
- High flow A coil overheated from repeated hard use
- Cracked coil housing
Checks
- 1Measure the high flow A solenoid coil; an open coil reads as no continuity
- 2Check the high flow A wires for continuity from the solenoid plug to the controller
- 3Use the service tool output test to energise the solenoid and listen for the click
- 4Feel the high flow A coil after work; a very hot or discoloured coil points to overheating
- 5Compare the high flow A cycle time with the figure in the manual
- 6Inspect the coil housing for cracks
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C0306High flow B solenoid short circuit
The hydraulic controller found the high flow B solenoid, which opens the larger flow path to high flow function B, shorted or drawing too much current, and switched the output off to protect itself; the high flow function B is slow or has no movement. High flow B movements are slow.· Short circuitShort circuitCheck soonCauses
- Wire to the high flow B solenoid chafed against the frame or the valve block
- High flow b solenoid coil shorted internally
- High flow B coil overheated from repeated hard use
- Overheated coil from continuous hammer or breaker work
Checks
- 1Unplug the high flow B solenoid and measure the coil resistance against the manual value
- 2With the plug off, check each high flow B wire for a short to ground
- 3Inspect the harness clip near the valve block for chafing from vibration
- 4Feel the high flow B coil after work; a very hot or discoloured coil points to overheating
- 5Compare the high flow B cycle time with the figure in the manual
- 6Let the coil cool then retest, and note whether the code returns when hot
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C0307High flow B solenoid open circuit
The hydraulic controller sees no current path through the high flow B solenoid, which opens the larger flow path to high flow function B, an open circuit, so the output cannot be driven; the high flow function B is slow or has no movement. High flow B movements are slow.· Open circuitOpen circuitCheck soonCauses
- Broken wire or loose pin at the high flow B solenoid plug
- High flow b solenoid coil burnt open
- High flow B coil overheated from repeated hard use
- Cracked coil housing
Checks
- 1Measure the high flow B solenoid coil; an open coil reads as no continuity
- 2Check the high flow B wires for continuity from the solenoid plug to the controller
- 3Check the earth connection of the hydraulic controller
- 4Feel the high flow B coil after work; a very hot or discoloured coil points to overheating
- 5Compare the high flow B cycle time with the figure in the manual
- 6Inspect the coil housing for cracks
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C0310Low flow ARV solenoid short circuit
The controller found the low flow ARV solenoid shorted. The ARV (anti-reaction valve) steadies the low flow circuit, so without it that function may jerk or lose smoothness. The low flow circuit may bounce when load changes.· Short circuitShort circuitCheck soonCauses
- Low flow ARV solenoid coil shorted
- Chafed ARV lead touching the frame
- Low flow ARV orifice blocked
- Anti-reaction cartridge worn in the low flow line
Checks
- 1Measure the low flow ARV coil resistance
- 2Check the ARV lead for a short to ground
- 3Check the valve block solenoid cartridge for a loose nut and a damaged O-ring
- 4Check the ARV valve for a blocked damping orifice
- 5Open the low flow circuit abruptly and watch for pressure spikes on the gauge
- 6Pull the low flow ARV cartridge and inspect the piston
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C0311Low flow ARV solenoid open circuit
The controller finds no current in the low flow ARV solenoid, so the anti-reaction valve cannot be commanded and the low flow function may feel unstable. The low flow circuit may bounce when load changes.· Open circuitOpen circuitCheck soonCauses
- Low flow ARV coil open or its plug loose
- Broken lead to the ARV solenoid
- Low flow ARV connector contaminated with oil
- Anti-reaction coil lead stretched on a moving hose bundle
Checks
- 1Check continuity of the low flow ARV coil and its lead
- 2Inspect the ARV plug for a pushed-back pin
- 3Measure the supply voltage at the hydraulic controller plug while the engine runs
- 4Dry and inspect the ARV plug for oil
- 5Open the low flow circuit abruptly and watch for pressure spikes on the gauge
- 6Check the lead strain relief at the hose bundle
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C0312High flow ARV proportional solenoid short circuit
The controller found the high flow ARV proportional solenoid shorted. This valve is driven proportionally, so a short removes the smooth control of the high flow circuit. The high flow circuit may feel harsh when starting and stopping.· Short circuitShort circuitCheck soonCauses
- High flow ARV proportional coil shorted
- Lead touching the frame
- Proportional ARV driver stage damaged
- Proportional coil overheated by constant duty
Checks
- 1Measure the high flow ARV coil resistance
- 2Check the lead for a short to ground
- 3Swap the solenoid plug with a similar solenoid of the same valve block and see whether the code moves
- 4Check the proportional drive current waveform with the tool if supported
- 5Compare the proportional ARV current ramp against a good machine's trace
- 6Feel the proportional ARV coil temperature after a long digging run
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB C0313High flow ARV solenoid open circuit
The controller finds no current in the high flow ARV solenoid, so the anti-reaction valve cannot be commanded and high flow movements may be harsh. The high flow circuit may feel harsh when starting and stopping.· Open circuitOpen circuitCheck soonCauses
- High flow ARV coil open or plug loose
- Broken lead
- High flow ARV lead chafed at the valve block
- Proportional ARV plug pins bent on refit
Checks
- 1Check continuity of the high flow ARV coil and its lead
- 2Inspect the plug for a pushed-back pin
- 3Check the hydraulic oil level and temperature, since cold oil makes current faults more likely
- 4Inspect the ARV lead for chafe where it leaves the block
- 5Compare the proportional ARV current ramp against a good machine's trace
- 6Inspect the ARV plug pins for bending
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C1335Pump 1 output open circuit
The controller finds an open circuit on the pump 1 output, the signal that sets the main pump displacement. With no current path, the pump may stay at a default setting. The main pump may stay at one displacement regardless of demand.· Open circuitOpen circuitCheck soonCauses
- Pump 1 regulator coil open
- Broken wire or loose plug at the pump 1 regulator
- Pump regulator connector pulled by hose movement
- Regulator coil lead brittle from heat near the pump
Checks
- 1Measure the pump 1 regulator coil for continuity
- 2Check the pump 1 harness plug and wires
- 3Check the plug seal for hydraulic oil inside the connector
- 4Check the pump regulator connector strain relief
- 5Check the pump regulator coil for continuity at the pump itself, not only at the cab harness
- 6Inspect the lead insulation near the pump for heat hardening
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB C1336Pump 1 output short circuit
The controller finds a short on the pump 1 output, the signal that sets the main pump displacement. The output is switched off, so the pump may drop to a default setting and the machine feels weak. The main pump may drop to a safe low displacement and feel weak across all functions.· Short circuitShort circuitCheck soonCauses
- Pump 1 regulator coil shorted
- Chafed wire to the pump regulator
- Pump regulator coil overheated by heat from the pump
- Regulator solenoid housing flooded with oil
Checks
- 1Measure the pump 1 regulator coil resistance
- 2Check the harness for a short to ground near the pump
- 3Compare commanded current with measured current on the live data screen
- 4Check for heat damage on the regulator lead near the pump body
- 5Check the pump regulator coil for a short at the pump itself, not only at the cab harness
- 6Dry the regulator plug and check for oil in the harness conduit
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Shared checks
Checks, in order
- 1Measure the solenoid resistance (on the flow solenoid, with the diagnostic tool and a multimeter)
- 2Check the wiring to the flow solenoid for opens, shorts to ground or battery, and chafing
- 3Run the output test on the diagnostic tool and listen or feel for the flow solenoid to operate
- 4Measure the hydraulic pressure at the flow solenoid with a gauge and compare with the manual
Causes
- Solenoid coil failed
- Wiring fault
- Connector corrosion
- Hydraulic restriction
Most common here: short circuit (9 of 22)
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
When to stop
You'll notice: The machine may have weak or no movement on the affected function.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Partao JCB fault code list, page 1 (code table)
- Partao JCB fault code list, page 2 (code table)
- Partao JCB fault code list, page 3 (code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.