JCB · Engine ECU (Dieselmax / Ecomax) - electrical
JCB ECU power relay, 5 V supply, injector power supply and starter circuit fault codes
The main relay powers the ECU or the dosing control unit (DCU) once the key is on, and holds power while the unit saves its data. The ECU feeds most sensors from regulated 5 V supplies.
More about these partsLess
A fault on a supply affects every sensor on it at once. The ECU boosts the supply to the injectors in a charge circuit and switches it to each bank. These codes cover the supply, the bank drivers and the relay that powers them. The ECU controls the starter relay and protects the starter from over-long cranking, repeated engagement and overheating.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes P06A7-00 to P3302 are all about the eCU power relay, 5 V supply, injector power supply and starter circuit. The most common failure type is shorted low (2 of 26); 2 need an immediate stop. Start with this check: check the relay and fuse and swap the relay with a known good one.
How urgent are they?
2 of 26 codes here mean stop now; the other 24 can wait until the shift ends, but find the cause before the next one.
- Stop now2
- Check soon24
What should I check first?
Check the relay and fuse and swap the relay with a known good one
Shared checks26 of 26
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB P06A7-00Sensor supply monitoring error through DCU
Sensor supply monitoring error through DCU. The controller logged a fault on the sensor supply monitoring error through DCU, which affects how the 5 V sensor supply works until the cause is found.· OtherOtherCheck soonCauses
- Sensor supply monitoring error through DCU or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the sensor supply monitoring error through DCU and look for a value that is stuck or implausible
- 2Check the sensor supply monitoring error through DCU connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P20EB-71DCU relay stuck
DCU relay stuck. The controller sees the DCU relay stuck behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- DCU relay stuck drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the DCU relay stuck circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the DCU relay stuck value on live data with a known good value or a reference gauge
- 2Check the DCU relay stuck connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P20EA-72DCU relay opens early
DCU relay opens early. The controller finds no current path in the DCU relay opens early circuit, so the ECU / DCU power relay cannot be driven or read as expected.· Open circuitOpen circuitCheck soonCauses
- Open wire or pushed-back pin between the controller and the DCU relay opens early
- DCU relay opens early coil, element or sensor internally open
Checks
- 1Unplug the DCU relay opens early and measure across its pins, an open reading means the part is faulty
- 2Check continuity of each wire from the DCU relay opens early plug to the controller pin
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P062BControl module fuel injector control performance
Control module fuel injector control performance. The controller sees the control module fuel injector control performance behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Control module fuel injector control performance drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the control module fuel injector control performance circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the control module fuel injector control performance value on live data with a known good value or a reference gauge
- 2Check the control module fuel injector control performance connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P062DInjector bank 0 shorted to ground
The ECU found the injector driver for bank 0 pulled to ground, so those injectors may not fire.· Shorted lowShorted lowStop nowCauses
- Injector wiring on bank 0 shorted to ground, often by chafing on the head or valve cover
- An injector coil on bank 0 shorted internally
- Water or oil in the bank 0 harness connector pulling the driver to ground
Checks
- 1Unplug the bank 0 injectors one at a time and see which one clears the short
- 2Measure each injector coil resistance and check each pin to engine ground
- 3Check the harness from the valve cover to the ECU for rub marks and pinch points
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JCB P062EInjector bank 1 shorted to ground
The ECU found the injector driver for bank 1 pulled to ground, the same fault as P062D but on the second injector bank. The affected cylinders may not fire, causing rough running, misfire or a no-start.· Shorted lowShorted lowStop nowCauses
- Injector wiring on bank 1 shorted to ground
- An injector coil on bank 1 shorted to its body
- Oil soaked connector at the valve cover shorting a pin to ground
Checks
- 1Disconnect the bank 1 injectors one at a time to find the one that clears the fault
- 2Measure each bank 1 injector coil for a short between pin and body
- 3Inspect the bank 1 harness for rub marks, burns or pinches
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JCB P0612Fuel injector control module relay control fault
Fuel injector control module relay control fault. The controller logged a fault on the fuel injector control module relay control, which affects how the injector supply and driver bank works until the cause is found.· OtherOtherCheck soonCauses
- Fuel injector control module relay control or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the fuel injector control module relay control and look for a value that is stuck or implausible
- 2Check the fuel injector control module relay control connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P0615Starter relay circuit fault
The controller sees a fault in the starter relay circuit, so the starter may not crank, or may stay engaged after the engine fires. The operator notices a no-crank or a starter that clicks.· OtherOtherCheck soonCauses
- Starter relay failed, or its contacts stuck or burnt
- Open or shorted starter relay control wire from the controller
- Weak battery or poor starter feed so the relay drops out
Checks
- 1Swap the starter relay with a known good relay of the same type
- 2Check the relay socket terminals for burning or corrosion
- 3Measure the voltage at the relay coil with the key turned to start
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P0616Starter relay circuit low
Starter relay circuit low. The reading or voltage for the starter relay is below the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- Starter relay signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the starter relay value on live data and compare it with the expected value
- 2Unplug the starter relay and check the signal wire for a short to ground and the supply for 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P0617Starter relay circuit high
Starter relay circuit high. The reading or voltage for the starter relay is above the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- Starter relay signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the starter relay value on live data and compare it with the expected value
- 2Unplug the starter relay and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P0641ECU 5 V sensor supply 1 fault
The 5 V reference line from the ECU is out of range for over 2 seconds. Sensors on that line give bad data.· OtherOtherCheck soonCauses
- 5 V supply 1 line shorted to ground by a damaged sensor or wire
- 5 V supply 1 shorted to battery or a signal wire
- A sensor on this supply failed internally and dragging the voltage down
- Connector fault at one of the sensors on this supply
- ECU internal supply failure, only after all else is cleared
Checks
- 1With the key on, measure the 5 V supply 1 voltage at the ECU or a sensor plug
- 2Unplug the sensors on supply 1 one at a time and see if the voltage recovers
- 3Use the ECU wiring diagram to find every sensor on supply 1
- 4Check the supply wire for chafing or shorts to ground or battery
- 5Check each sensor connector for water and corrosion
- 6Look at the other stored sensor codes for a pattern pointing to the shared supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P0651ECU 5 V sensor supply 2 fault
The second 5 V sensor supply from the ECU is out of range, so all sensors on that line give bad data. Expect several sensor codes at once, reduced power and possibly limp mode.· OtherOtherCheck soonCauses
- Supply 2 wire pinched or rubbed through and touching ground
- Supply 2 wire touching battery voltage or a signal wire
- One of the sensors fed from supply 2 failed and pulling the voltage down
Checks
- 1Measure the supply 2 voltage at the ECU connector with the key on
- 2Disconnect the sensors fed by supply 2 one at a time and watch the voltage
- 3Read the wiring diagram to list which sensors share this supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P0685ECU power relay control circuit open
The relay that powers the engine ECU is not being controlled properly, so ECU power may drop out.· Open circuitOpen circuitCheck soonCauses
- ECU main power relay failed, or its contacts burnt
- Relay control wire open between the ECU and the relay
- Corroded relay socket or loose terminals
- Blown fuse in the ECU supply
- Poor battery or earth connection to the relay
Checks
- 1Swap the relay with a known good one of the same type
- 2Check the relay socket terminals for burning, corrosion and looseness
- 3Check the fuse feeding the relay and the supply circuit
- 4Measure the voltage at the ECU supply pins with key on and the relay energised
- 5Check the relay coil control wire for continuity back to the ECU
- 6Listen for the relay to click when the key is turned on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P0687Main relay system fault (closed)
Main relay system fault (closed). The controller logged a fault on the main relay system, which affects how the ECU / DCU power relay works until the cause is found.· OtherOtherCheck soonCauses
- Main relay system or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the main relay system and look for a value that is stuck or implausible
- 2Check the main relay system connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P0697ECU 5 V sensor supply 3 fault
The third 5 V sensor supply from the ECU is out of range, so every sensor on that line gives bad data. Expect several sensor codes at once and possibly reduced power or limp mode.· OtherOtherCheck soonCauses
- Supply 3 wire shorted to ground
- Supply 3 wire shorted to battery or another signal
- A single sensor on supply 3 failed internally and pulling the line down
Checks
- 1Measure the supply 3 voltage at the ECU or at a sensor plug with the key on
- 2Unplug each sensor on supply 3 in turn to find one that restores the voltage
- 3Check the ECU wiring diagram to see which sensors are fed from supply 3
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P1261Cylinder 1 fuel injector circuit malfunction
Cylinder 1 fuel injector circuit malfunction. The controller logged a fault on the cylinder 1 fuel injector circuit malfunction, which affects how the injector supply and driver bank works until the cause is found.· OtherOtherCheck soonCauses
- Cylinder 1 fuel injector circuit malfunction or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the cylinder 1 fuel injector circuit malfunction and look for a value that is stuck or implausible
- 2Check the cylinder 1 fuel injector circuit malfunction connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P1262Charge circuit fault on bank 2
Charge circuit fault on bank 2. The controller logged a fault on the charge circuit fault on bank 2, which affects how the injector supply and driver bank works until the cause is found.· OtherOtherCheck soonCauses
- Charge circuit fault on bank 2 or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the charge circuit fault on bank 2 and look for a value that is stuck or implausible
- 2Check the charge circuit fault on bank 2 connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P1602Starter relay control circuit global fault
Starter relay control circuit global fault. The controller logged a fault on the starter relay control circuit global, which affects how the starter relay and starter protection works until the cause is found.· OtherOtherCheck soonCauses
- Starter relay control circuit global or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the starter relay control circuit global and look for a value that is stuck or implausible
- 2Check the starter relay control circuit global connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P16555 V power supply 4 voltage fault
5 V power supply 4 voltage fault. The controller logged a fault on the 5 V power supply 4 voltage, which affects how the 5 V sensor supply works until the cause is found.· OtherOtherCheck soonCauses
- 5 V power supply 4 voltage or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the 5 V power supply 4 voltage and look for a value that is stuck or implausible
- 2Check the 5 V power supply 4 voltage connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2146Injector supply voltage fault
Injector supply voltage fault. The controller logged a fault on the injector supply voltage, which affects how the injector supply and driver bank works until the cause is found.· OtherOtherCheck soonCauses
- Injector supply voltage or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the injector supply voltage and look for a value that is stuck or implausible
- 2Check the injector supply voltage connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2147Injector voltage source cutoff malfunction
Injector voltage source cutoff malfunction. The controller logged a fault on the injector voltage source cutoff malfunction, which affects how the injector supply and driver bank works until the cause is found.· OtherOtherCheck soonCauses
- Injector voltage source cutoff malfunction or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the injector voltage source cutoff malfunction and look for a value that is stuck or implausible
- 2Check the injector voltage source cutoff malfunction connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2148Injector voltage source cutoff malfunction (bank 2)
Injector voltage source cutoff malfunction (bank 2). The controller logged a fault on the injector voltage source cutoff malfunction, which affects how the injector supply and driver bank works until the cause is found.· OtherOtherCheck soonCauses
- Injector voltage source cutoff malfunction or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the injector voltage source cutoff malfunction and look for a value that is stuck or implausible
- 2Check the injector voltage source cutoff malfunction connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2149Injection nozzle common 2 drive system fault
Injection nozzle common 2 drive system fault. The controller logged a fault on the injection nozzle common 2 drive system, which affects how the injector supply and driver bank works until the cause is found.· OtherOtherCheck soonCauses
- Injection nozzle common 2 drive system or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the injection nozzle common 2 drive system and look for a value that is stuck or implausible
- 2Check the injection nozzle common 2 drive system connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3300Starter motor engagement protection fault
Starter motor engagement protection fault. The controller logged a fault on the starter motor engagement protection, which affects how the starter relay and starter protection works until the cause is found.· OtherOtherCheck soonCauses
- Starter motor engagement protection or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the starter motor engagement protection and look for a value that is stuck or implausible
- 2Check the starter motor engagement protection connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3301Starter motor overheat protection activated
Starter motor overheat protection activated. The reading or voltage for the starter motor overheat protection activated is above the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- Starter motor overheat protection activated signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the starter motor overheat protection activated value on live data and compare it with the expected value
- 2Unplug the starter motor overheat protection activated and check the signal wire for a short to 5 V or battery
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P3302Starter motor overrun protection fault
Starter motor overrun protection fault. The controller logged a fault on the starter motor overrun protection, which affects how the starter relay and starter protection works until the cause is found.· OtherOtherCheck soonCauses
- Starter motor overrun protection or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the starter motor overrun protection and look for a value that is stuck or implausible
- 2Check the starter motor overrun protection connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Check the relay and fuse and swap the relay with a known good one
- 2Unplug the sensors on the affected supply one at a time and see if the code clears
- 3Look at which cylinders are affected, because a single bank points to its wiring or one injector
- 4Check the starter relay and its coil circuit (on the starter relay and starter protection, with the diagnostic tool and a multimeter)
- 5Measure voltage at the relay output when it is commanded on
- 6Measure the 5 V at a sensor plug with the key on
- 7Unplug the injectors one at a time and see if the fault clears
Causes
- Relay or fuse faulty
- A shorted sensor pulling the supply down
- Injector bank wiring shorted to ground or supply
- Starter relay or its wiring faulty
Most common here: shorted low (2 of 26)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: The engine may not start, may stall or the ECU may lose power, and a check lamp is on.
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Partao JCB fault code P0685 page
- Partao JCB fault code list, page 9 (code table)
- Partao JCB fault code list, page 12 (code table)
- Partao JCB fault code list, page 8 (code table)
- Partao JCB fault code P0641 page
- Partao JCB fault code list, page 10 (code table)
- Partao JCB fault code list, page 15 (code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
