Deutz · Cooling and fan

Deutz Fan drive, fan control and fan speed fault codes

The cooling fan system the EMR4 controls: the fan drive output (a valve or clutch), the fan control and the fan speed signal. Each code names which part failed and whether it is a short, an open circuit or an implausible speed.

FaultCheckSPN 975FMI 3Deutz · Engine - Fan
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 975 FMI 3 to SPN 524196 FMI 13 are all about the fan drive, fan control and fan speed. The most common failure type is real condition (5 of 22); none needs an immediate stop. Start with this check: measure the fan drive coil resistance and check its plug.

How urgent are they?

None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.

  • Check soon22

What should I check first?

Measure the fan drive coil resistance and check its plug

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Engine - Fan8 codes

    • Deutz SPN 975 FMI 3Engine - Fan: Voltage high / shorted high

      The EMR4 sees the output for the fan drive output (at the fan control (hydraulic or electric fan drive) on the cooling system) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Fan drive output shorted internally
      • Fan control valve connector corroded
      • Connector pin touching a live pin

      Checks

      1. 1With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      2. 2Measure the winding or coil resistance of the part
      3. 3Unplug the fan drive output: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      4. 4Command the fan from SerDia and confirm it responds
      5. 5Check that the fan control valve and its harness are intact
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Fan - Voltage above normal or shorted to high source

    • Deutz SPN 975 FMI 4Engine - Fan: Voltage low / shorted low

      The EMR4 sees the output for the fan drive output (at the fan control (hydraulic or electric fan drive) on the cooling system) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Water in the connector bridging the pins
      • Fan control valve connector corroded
      • Output wire chafed to ground or the engine block
      • Fan drive output winding shorted to its housing

      Checks

      1. 1Check that the fan control valve and its harness are intact
      2. 2Command the fan from SerDia and confirm it responds
      3. 3Unplug the fan drive output: if the code changes, the part is the shorted one; if it stays, look at the harness
      4. 4Measure the winding resistance of the part and look for a very low value
      5. 5With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Fan - Voltage below normal or shorted to low source

    • Deutz SPN 975 FMI 5Engine - Fan: Current low / open circuit

      The EMR4 sees too little current through the fan drive output (at the fan control (hydraulic or electric fan drive) on the cooling system), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Connector left unplugged after earlier work
      • Fan control valve connector corroded
      • Broken wire or a pin pushed out of the connector

      Checks

      1. 1Command the fan from SerDia and confirm it responds
      2. 2Check that the fan control valve and its harness are intact
      3. 3Inspect both ends of the fan drive output circuit (EMR4 plug and part connector) for pins pushed back in the housing
      4. 4Continuity-test each wire to the matching EMR4 pin
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Engine - Fan - Current below normal or open circuit

    • Deutz SPN 523992 FMI 9Engine - Fan: Abnormal update rate timeout

      The EMR4 sees the fan (at the fan control (hydraulic or electric fan drive) on the cooling system) update at an abnormal rate or time out.· Lost message
      Check soon

      Causes

      • Interrupted wiring or connector to the sending unit
      • Sending unit not powered or in reset

      Checks

      1. 1Check the supply and ground of the sending unit with the key on
      2. 2Inspect the connector and wiring for chafe, moisture and loose pins
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524159 FMI 0Engine - Fan: Reading too high· most severe

      The EMR4 sees the fan (at the fan control (hydraulic or electric fan drive) on the cooling system) above its allowed range.· Real condition
      Check soon

      Causes

      • Part driven beyond its limit
      • Failed part or a real condition behind the signal

      Checks

      1. 1Read the actual value against the target in SerDia
      2. 2Check the fan moves freely through its range by hand with the key off
      3. 3Inspect the supply and control wiring of the fan for chafe, water and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Fan - Data above normal operational range (Most severe level)

    • Deutz SPN 524159 FMI 1Engine - Fan: Reading too low· most severe

      The EMR4 sees the fan (at the fan control (hydraulic or electric fan drive) on the cooling system) below its allowed range.· Real condition
      Check soon

      Causes

      • Part not reaching its commanded value
      • Failed part or a real condition behind the signal

      Checks

      1. 1Read the actual value against the target in SerDia
      2. 2Check the part moves through its full travel by hand with the key off
      3. 3Inspect the supply and control wiring of the fan for chafe, water and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Fan - Data below normal operational range (Most severe level)

    • Deutz SPN 524196 FMI 2Engine - Fan: Erratic reading

      The EMR4 sees the fan (at the fan control (hydraulic or electric fan drive) on the cooling system) behave erratically against the command, which can mean a sticking part or an intermittent connection.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector
      • Failed part or a real condition behind the signal

      Checks

      1. 1Command the fan from SerDia and watch actual versus commanded behaviour for lag or dropouts
      2. 2Wiggle the fan harness and connector while watching the live status in SerDia for dropouts
      3. 3Check both connector halves of the fan for loose, bent or fretted pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - Fan - Data erratic intermittent or incorrect

    • Deutz SPN 524196 FMI 13Engine - Fan: Out of calibration

      The EMR4 reports the fan (at the fan control (hydraulic or electric fan drive) on the cooling system) as out of calibration.· Part or controller
      Check soon

      Causes

      • Fan replaced without a recalibration
      • Mechanical wear or play shifting the end positions

      Checks

      1. 1Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the fan
      2. 2Check the fan for mechanical play or a loose linkage that shifts its end positions
      3. 3Replace the fan if the end-position learn routine in SerDia fails repeatedly
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Engine - Fan rotation speed4 codes

    • Deutz SPN 1639 FMI 0Engine - Fan rotation speed: Reading too high· most severe

      The EMR4 sees the fan rotation speed above its normal range.· Real condition
      Check soon

      Causes

      • Fan drive valve stuck open
      • Speed sensor reading high
      • Fan control signal shorted high

      Checks

      1. 1Compare the fan speed command and the actual fan speed in SerDia to see how far apart they are
      2. 2Check the fan control valve for a stuck spool that holds the fan at full speed
      3. 3Check the fan speed sensor signal for a false high value
      4. 4Check the fan control wiring for a short to supply that holds the command high
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Fan rotation speed - Data above normal operational range (Most severe level)

    • Deutz SPN 1639 FMI 1Engine - Fan rotation speed: Reading too low· most severe

      The EMR4 sees the fan rotation speed below its normal range.· Real condition
      Check soon

      Causes

      • Fan drive valve stuck closed
      • Fan belt or hydraulic supply weak
      • Speed sensor reading low
      • Fan blades blocked

      Checks

      1. 1Compare the fan speed command and the actual fan speed in SerDia to see how far apart they are
      2. 2Check the fan drive pressure or belt condition, depending on the fan type
      3. 3Check the fan for obstruction or debris around the blades and shroud
      4. 4Check the fan speed sensor signal for a false low value
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Fan rotation speed - Data below normal operational range (Most severe level)

    • Deutz SPN 1639 FMI 12Engine - Fan rotation speed: Bad device or component

      The EMR4 judges the fan rotation speed signal to be a bad device.· Part or controller
      Check soon

      Causes

      • Fan speed sensor failed
      • Sensor harness chafed at the fan shroud
      • Sensor gap too large
      • Connector corroded

      Checks

      1. 1Compare the fan speed shown in SerDia with what you see at the fan
      2. 2Check the fan speed sensor mounting and gap at the fan shroud
      3. 3Inspect the harness and connector at the fan for chafing and water
      4. 4Replace the fan speed sensor if its signal is missing while the fan visibly turns
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Fan rotation speed - Bad intelligent device or component

    • Deutz SPN 523602 FMI 0Engine - Fan rotation speed: Reading too high· most severe

      The EMR4 rates the fan rotation speed (at the fan speed sensor on the cooling fan drive) as above its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really above its limit, for example from overload or a blockage
      • Signal or part drifting high with age

      Checks

      1. 1Read the fan rotation speed value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of an excessive value, such as a restriction or an overloaded function
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Fan rotation speed - Data above normal operational range (Most severe level)

  • Machine - CAN fan control1 code

    • Deutz SPN 524157 FMI 9Machine - CAN fan control: Abnormal update rate timeout

      The EMR4 sees the CAN fan control (on the electronic fan control of the cooling system) update at an abnormal rate or time out.· Lost message
      Check soon

      Causes

      • Interrupted wiring or connector to the sending unit
      • Sending unit not powered or in reset

      Checks

      1. 1Check the supply and ground of the sending unit with the key on
      2. 2Inspect the connector and wiring for chafe, moisture and loose pins
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - Fan control8 codes

    • Deutz SPN 524160 FMI 3Engine - Fan control: Voltage high / shorted high

      The EMR4 sees the output for the fan control (on the electronic fan control of the cooling system) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • Fan control shorted internally

      Checks

      1. 1Unplug the fan control: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Fan control - Voltage above normal or shorted to high source

    • Deutz SPN 524160 FMI 4Engine - Fan control: Voltage low / shorted low

      The EMR4 sees the output for the fan control (on the electronic fan control of the cooling system) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • Fan control winding shorted to its housing
      • Water in the connector bridging the pins

      Checks

      1. 1Unplug the fan control: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Fan control - Voltage below normal or shorted to low source

    • Deutz SPN 524160 FMI 5Engine - Fan control: Current low / open circuit

      The EMR4 sees too little current through the fan control (on the electronic fan control of the cooling system), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • Fan control winding open
      • Connector left unplugged after earlier work

      Checks

      1. 1Measure the resistance across the fan control terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the fan control circuit (EMR4 plug and part connector) for pins pushed back in the housing
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Engine - Fan control - Current below normal or open circuit

    • Deutz SPN 524161 FMI 3Engine - Fan control: Voltage high / shorted high

      The EMR4 sees the output for the fan control (on the electronic fan control of the cooling system) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • Fan control shorted internally

      Checks

      1. 1Unplug the fan control: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Fan control - Voltage above normal or shorted to high source

    • Deutz SPN 524161 FMI 4Engine - Fan control: Voltage low / shorted low

      The EMR4 sees the output for the fan control (on the electronic fan control of the cooling system) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • Fan control winding shorted to its housing
      • Water in the connector bridging the pins

      Checks

      1. 1Unplug the fan control: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Fan control - Voltage below normal or shorted to low source

    • Deutz SPN 524161 FMI 5Engine - Fan control: Current low / open circuit

      The EMR4 sees too little current through the fan control (on the electronic fan control of the cooling system), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • Fan control winding open
      • Connector left unplugged after earlier work

      Checks

      1. 1Measure the resistance across the fan control terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the fan control circuit (EMR4 plug and part connector) for pins pushed back in the housing
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Engine - Fan control - Current below normal or open circuit

    • Deutz SPN 524163 FMI 12Engine - Fan control: Bad device or component

      The EMR4 judges the fan control (on the electronic fan control of the cooling system) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Internal failure of the fan control
      • Water or soot inside the part
      • Driver stage in the EMR4 failing

      Checks

      1. 1Read the fan control status in SerDia and run any actuator test
      2. 2Measure supply voltage and ground at the fan control connector with the key on to confirm the part is powered
      3. 3Fit a known good fan control if you can borrow one and see whether the code clears for good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Fan control - Bad intelligent device or component

    • Deutz SPN 524192 FMI 12Engine - Fan control: Bad device or component

      The EMR4 judges the fan control (on the electronic fan control of the cooling system) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Internal failure of the fan control
      • Water or soot inside the part
      • Driver stage in the EMR4 failing

      Checks

      1. 1Read the fan control status in SerDia and run any actuator test
      2. 2Measure supply voltage and ground at the fan control connector with the key on to confirm the part is powered
      3. 3Fit a known good fan control if you can borrow one and see whether the code clears for good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Fan control - Bad intelligent device or component

  • Engine - Fan control angle sensor1 code

    • Deutz SPN 524162 FMI 12Engine - Fan control angle sensor: Bad device or component

      The EMR4 judges the fan control angle sensor (on the electronic fan control of the cooling system) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Internal failure of the fan control angle sensor
      • Water or soot inside the part
      • Driver stage in the EMR4 failing

      Checks

      1. 1Read the fan control angle sensor status in SerDia and run any actuator test
      2. 2Measure supply voltage and ground at the fan control angle sensor connector with the key on to confirm the part is powered
      3. 3Fit a known good fan control angle sensor if you can borrow one and see whether the code clears for good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Fan control angle sensor - Bad intelligent device or component

Shared checks

Checks, in order

  1. 1Measure the fan drive coil resistance and check its plug
  2. 2Read commanded and actual fan speed in SerDia
  3. 3Inspect the speed sensor and its tone wheel for debris
  4. 4Turn the fan by hand with the key off to check it is free

Causes

  • Fan drive valve or clutch coil open or shorted
  • Fan speed sensor dirty or its signal lost
  • Wiring or connector fault between the EMR4 and the fan drive
  • Fan mechanically stuck or the belt slipping

Most common here: real condition (5 of 22)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A warning lamp or limited function.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.