EF Logo

Detroit · EGR system

Detroit EGR valve actuator and EGR flow fault codes

The EGR valve is moved by a smart remote actuator (SRA3) that talks to the MCM on its own CAN line. Detroit logs actuator communication, supply voltage, learn cycle, position, frozen-valve and slow-response faults, as well as flow target, cooler and delta pressure errors.

FaultCheckSPN 2791FMI 7Detroit · EGR valve actuator and EGR flow
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.

What do these codes mean?

Detroit codes SPN 411 FMI 2 to SPN 521179 FMI 18 are all about the eGR valve actuator and EGR flow. The most common failure type is real condition (10 of 29); none needs an immediate stop. Start with this check: check the EGR actuator connector and its supply voltage and ground.

How urgent are they?

None of the 29 codes here means stop now; all 29 can wait until the shift ends, but find the cause before the next one.

  • Check soon29

What should I check first?

Check the EGR actuator connector and its supply voltage and ground.

Shared checks

29 of 29

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Detroit SPN 411 FMI 2Exhaust Gas Recirculation Delta P Sensor Out Of Calibration

    Detroit lists SPN 411 FMI 2 as "Exhaust Gas Recirculation Delta P Sensor Out Of Calibration".· Erratic or implausible
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3Zero the delta pressure sensor with the engine off and see whether it reads near zero; if not, the sensor is out of calibration.
    4. 4Read the delta pressure with the engine off; it should be near zero, and an offset means the sensor must be replaced or re-zeroed.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 411 FMI 3EGR Delta Pressure Sensor Circuit Failed High

    Detroit lists SPN 411 FMI 3 as "EGR Delta Pressure Sensor Circuit Failed High".· Shorted high
    Check soon

    Causes

    • Output wire of the EGR valve actuator rubbed through and touching a live wire
    • Internal short in the EGR valve actuator

    Checks

    1. 1Unplug the EGR valve actuator and look for voltage on the output wire with the key on.
    2. 2Measure the EGR valve actuator winding resistance and compare it with a good unit.
    3. 3Unplug the EGR delta pressure sensor and check for a signal near the supply voltage, then inspect the two pressure hoses.
    4. 4High delta pressure reading: check the two sensor hoses for water or blockage that can hold the reading high.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 411 FMI 4EGR Delta Pressure Sensor Circuit Failed Low

    Detroit lists SPN 411 FMI 4 as "EGR Delta Pressure Sensor Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • Output wire of the EGR valve actuator rubbed through against the engine
    • Internal short in the EGR valve actuator

    Checks

    1. 1Unplug the EGR valve actuator and check the output wire for continuity to ground.
    2. 2Measure the EGR valve actuator winding resistance and look for a very low value.
    3. 3Check the sensor signal wire for a short to ground and the hoses for water, which can drag the reading down.
    4. 4Low reading: check the sensor signal for a short to ground and the hose connections for leaks.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 411 FMI 13EGR Delta Pressure Sensor Out Of Calibration

    Detroit lists SPN 411 FMI 13 as "EGR Delta Pressure Sensor Out Of Calibration".· Part or controller
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3Check that the calibration of the delta pressure sensor was not lost during a software change and redo the offset learn.
    4. 4Out of calibration: re-learn the sensor offset and check the software version for a known correction.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 2659 FMI 0Exhaust Gas Recirculation Flow Target Error Diagnostic - High Flow

    Detroit lists SPN 2659 FMI 0 as "Exhaust Gas Recirculation Flow Target Error Diagnostic - High Flow".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3High EGR flow: check whether the EGR valve is stuck open or the delta pressure sensor is under-reading.
    4. 4Flow too high: check for an EGR valve that sticks open and for an under-reading delta pressure sensor.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 2659 FMI 18Exhaust Gas Recirculation Flow Target Error Diagnostic - Low Flow

    Detroit lists SPN 2659 FMI 18 as "Exhaust Gas Recirculation Flow Target Error Diagnostic - Low Flow".· Real condition
    Check soon

    Causes

    • EGR valve not opening fully because of carbon
    • Restricted EGR passage or cooler

    Checks

    1. 1Command the valve to full open in the tool and watch the position feedback.
    2. 2Inspect the EGR passages and cooler for carbon and restriction.
    3. 3Low EGR flow: check for a blocked EGR cooler, a stuck valve or a leak that bypasses the measured path.
    4. 4Flow too low: check for a restricted EGR cooler, carbon in the valve, and an over-reading delta pressure sensor.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 2791 FMI 2EGR Valve Actuator, Position Deviation Error

    Detroit lists SPN 2791 FMI 2 as "EGR Valve Actuator, Position Deviation Error".· Erratic or implausible
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3Command the EGR valve to a set position and watch the position feedback; a gap between them means the valve is sticking.
    4. 4The commanded position and the feedback differ; command a sweep and note where the valve lags.
    5. 5Position deviation shows up when the valve is slowed by deposits or by a weak motor; log the commanded and measured position through a few steps to see the lag.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 2791 FMI 7EGR Valve Actuator, Fail Safe Mode, Motor On

    The EGR valve actuator went into its fail-safe mode with the motor switched off.· Part or controller
    Check soon

    Causes

    • Actuator seized with carbon
    • Actuator motor or its electronics failed
    • Low supply voltage or poor connector contact
    • Communication loss on the CAN3 line

    Checks

    1. 1Check the supply voltage and the ground at the EGR actuator connector with the key on.
    2. 2Command a learn cycle in the tool and watch whether the valve moves and reports its position.
    3. 3Remove the valve and inspect the flap and passage for carbon and sticking.
    4. 4Check the CAN3 wiring between the actuator and the MCM for continuity and shorts.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 2791 FMI 9Smart Remote Actuator 3 (EGR), No Communication

    Detroit lists SPN 2791 FMI 9 as "Smart Remote Actuator 3 (EGR), No Communication".· Lost message
    Check soon

    Causes

    • Open or shorted CAN3 wiring between the MCM and the actuator
    • Actuator without supply or ground

    Checks

    1. 1Check the CAN3 wires to the actuator for continuity and shorts.
    2. 2Check the actuator supply and ground at the connector.
    3. 3Check CAN3 between the MCM and SRA3 for continuity, and the actuator supply, since the MCM hears nothing from it.
    4. 4No communication with SRA3: measure the CAN3 wires for continuity and the actuator supply and ground.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 2791 FMI 11EGR Valve Actuator Common Fault

    Detroit lists SPN 2791 FMI 11 as "EGR Valve Actuator Common Fault".· Other
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The actuator reports a general internal fault; check the supply and ground and replace the actuator if the wiring is good.
    4. 4A common fault means the actuator reports an unspecific internal problem; check the supply and ground then replace the actuator.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Detroit SPN 2791 FMI 12EGR Valve Actuator Frozen

    Detroit lists SPN 2791 FMI 12 as "EGR Valve Actuator Frozen".· Part or controller
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3Remove the valve and check whether the shaft turns by hand; a valve frozen with carbon will not move when commanded.
    4. 4A frozen valve shows no movement; remove it and turn the shaft by hand to feel for carbon binding.
    5. 5A frozen valve normally follows a long period of low-load running, when soot and oil bake onto the shaft; after cleaning, run the learn so the end stops are known again.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 2791 FMI 13Smart Remote Actuator 3 (EGR), Calibration Error

    Detroit lists SPN 2791 FMI 13 as "Smart Remote Actuator 3 (EGR), Calibration Error".· Part or controller
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3Redo the actuator calibration with the tool and check that it completes without error.
    4. 4A calibration error needs the actuator to relearn; run the learn with the engine off and check it completes.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 2791 FMI 14EGR Valve Actuator, Wrong Fail Safe Calibration

    Detroit lists SPN 2791 FMI 14 as "EGR Valve Actuator, Wrong Fail Safe Calibration".· Part or controller
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The failsafe calibration stored in the actuator is wrong; reload the actuator data or replace the actuator.
    4. 4The wrong fail-safe calibration is stored in the actuator; reload the actuator data or fit a correct unit.
    5. 5Failsafe calibration decides where the valve rests when power is lost; a wrong stored value can leave it partly open, so compare it with the data of a known good actuator.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 2791 FMI 16EGR Valve Actuator Learn Cycle Too Large

    Detroit lists SPN 2791 FMI 16 as "EGR Valve Actuator Learn Cycle Too Large".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The learned travel is larger than expected, which suggests a worn or loose linkage or a valve that no longer stops at its seat.
    4. 4A learn cycle that is too large means the valve travels further than expected; check the linkage and valve seat.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 2791 FMI 18EGR Valve Actuator Learn Cycle Too Small

    Detroit lists SPN 2791 FMI 18 as "EGR Valve Actuator Learn Cycle Too Small".· Real condition
    Check soon

    Causes

    • EGR valve not opening fully because of carbon
    • Restricted EGR passage or cooler

    Checks

    1. 1Command the valve to full open in the tool and watch the position feedback.
    2. 2Inspect the EGR passages and cooler for carbon and restriction.
    3. 3The learned travel is smaller than expected, which suggests carbon on the valve limiting its movement.
    4. 4A learn cycle that is too small means the travel is limited; look for carbon blocking the valve.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 2791 FMI 31EGR Valve Actuator Slow Response

    Detroit lists SPN 2791 FMI 31 as "EGR Valve Actuator Slow Response".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3Time the valve movement in the tool; a slow response points to carbon, low supply voltage or a weak actuator motor.
    4. 4Slow response: time the valve between positions and check the supply voltage while it moves.
    5. 5A valve that is slow only when cold often has stiff grease or deposits, while one that is slow hot often has a weak supply, so note the temperature when the code sets.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 3058 FMI 9Exhaust Gas Recirculation Slow Response - Low Box

    Detroit lists SPN 3058 FMI 9 as "Exhaust Gas Recirculation Slow Response - Low Box".· Lost message
    Check soon

    Causes

    • Open or shorted CAN3 wiring between the MCM and the actuator
    • Actuator without supply or ground

    Checks

    1. 1Check the CAN3 wires to the actuator for continuity and shorts.
    2. 2Check the actuator supply and ground at the connector.
    3. 3The EGR response is slow in the low box; check the actuator speed and the CAN link to the valve.
    4. 4Slow EGR response in the low box: check the actuator speed and the CAN link.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 3058 FMI 10Exhaust Gas Recirculation Slow Response

    Detroit lists SPN 3058 FMI 10 as "Exhaust Gas Recirculation Slow Response".· Erratic or implausible
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The EGR response is slow; command a step change in the valve position and time it in the tool.
    4. 4Slow EGR response: command a step and time the position change.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 4752 FMI 17Exhaust Gas Recirculation Cooler Performance Monitor

    Detroit lists SPN 4752 FMI 17 as "Exhaust Gas Recirculation Cooler Performance Monitor".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The EGR cooler performance monitor failed; check the cooler for fouling and the EGR temperatures.
    4. 4EGR cooler performance: compare the gas temperature before and after the cooler and look for a coolant leak.
    5. 5Cooler performance compares the temperature of the gas before and after the cooler with what the coolant flow should achieve, so a fouled core or low coolant flow gives the same code.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 5588 FMI 9Exhaust Gas Recirculation Actuator, CAN3 Communication Error

    Same failure as SPN 2791 FMI 9 ("Smart Remote Actuator 3 (EGR), No Communication") on a sibling part: Detroit lists SPN 5588 FMI 9 as "Exhaust Gas Recirculation Actuator, CAN3 Communication Error".· Lost message
    Check soon

    Causes

    • The causes listed under SPN 2791 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 2791 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 5588 FMI 14Chassis-CAN (VCAN/Prop Net #2) - Bus off

    Detroit lists SPN 5588 FMI 14 as "Chassis-CAN (VCAN/Prop Net #2) - Bus off".· Lost message
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The chassis CAN is bus off; check the chassis CAN wires for shorts and the modules on that bus.
    4. 4The chassis CAN is bus off; unplug the EGR actuator and see whether the bus recovers.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 5765 FMI 0EGR Temperature Alert

    Detroit lists SPN 5765 FMI 0 as "EGR Temperature Alert".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The EGR temperature alert means the EGR gas is too hot; check the cooler and the coolant flow.
    4. 4EGR temperature alert: check the coolant flow through the cooler and the thermostat.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520296 FMI 3Exhaust Gas Recirculation Valve Actuator, Low Supply Voltage

    Detroit lists SPN 520296 FMI 3 as "Exhaust Gas Recirculation Valve Actuator, Low Supply Voltage".· Shorted high
    Check soon

    Causes

    • Output wire of the EGR valve actuator rubbed through and touching a live wire
    • Internal short in the EGR valve actuator

    Checks

    1. 1Unplug the EGR valve actuator and look for voltage on the output wire with the key on.
    2. 2Measure the EGR valve actuator winding resistance and compare it with a good unit.
    3. 3The EGR actuator supply voltage is low; measure the supply at the actuator connector under load.
    4. 4Low EGR actuator supply: measure at the connector while the valve moves.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 520296 FMI 11Smart Remote Actuator 3 (EGR), Learn Command Pending

    Detroit lists SPN 520296 FMI 11 as "Smart Remote Actuator 3 (EGR), Learn Command Pending".· Shorted low
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3An EGR actuator learn command is pending; run the learn procedure in the tool.
    4. 4A learn command is waiting; run the learn so the actuator can complete the pending request.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 520296 FMI 31Exhaust Gas Recirculation Valve Actuator, Learn Cycle Incomplete

    Detroit lists SPN 520296 FMI 31 as "Exhaust Gas Recirculation Valve Actuator, Learn Cycle Incomplete".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The EGR actuator learn cycle did not finish; repeat the learn with the engine off and the key on.
    4. 4The learn cycle did not complete; repeat it and watch for a reason in the tool.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 521027 FMI 9EGR Valve Actuator No Longer Communicating On MCM CAN3

    Same failure as SPN 2791 FMI 9 ("Smart Remote Actuator 3 (EGR), No Communication") on a sibling part: Detroit lists SPN 521027 FMI 9 as "EGR Valve Actuator No Longer Communicating On MCM CAN3".· Lost message
    Check soon

    Causes

    • The causes listed under SPN 2791 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 2791 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 521030 FMI 9Smart Remote Actuator 3 (EGR), No Communication

    Same failure as SPN 2791 FMI 9 ("Smart Remote Actuator 3 (EGR), No Communication") on a sibling part: Detroit lists SPN 521030 FMI 9 as "Smart Remote Actuator 3 (EGR), No Communication".· Lost message
    Check soon

    Causes

    • The causes listed under SPN 2791 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 2791 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 521179 FMI 16EGR PID Controller Limit High Side

    Detroit lists SPN 521179 FMI 16 as "EGR PID Controller Limit High Side".· Real condition
    Check soon

    Causes

    • Wiring, supply or mechanical problem on the EGR valve actuator
    • Controller output fault

    Checks

    1. 1Read the freeze-frame data for this code and note the engine state.
    2. 2Command the EGR valve actuator in the tool and watch the result.
    3. 3The EGR controller is at its high limit; check for a stuck valve or a sensor error.
    4. 4The EGR control loop reached its high limit; look for a valve stuck closed or a delta pressure sensor reading too high.
    5. 5The EGR PID limit on the high side means the controller keeps asking for more opening and cannot get the flow it wants; check for a restriction after the valve.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 521179 FMI 18EGR PID Controller Limit Low Side

    Detroit lists SPN 521179 FMI 18 as "EGR PID Controller Limit Low Side".· Real condition
    Check soon

    Causes

    • EGR valve not opening fully because of carbon
    • Restricted EGR passage or cooler

    Checks

    1. 1Command the valve to full open in the tool and watch the position feedback.
    2. 2Inspect the EGR passages and cooler for carbon and restriction.
    3. 3The EGR controller is at its low limit; check for a restricted EGR path.
    4. 4The EGR control loop reached its low limit; look for a valve stuck open or a delta pressure sensor reading too low.
    5. 5The EGR PID limit on the low side means the controller keeps asking for less flow and the valve cannot close enough, which points at a leaking or stuck-open valve.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Check the EGR actuator connector and its supply voltage and ground.
  2. 2Command the actuator in the tool and watch whether the valve moves and learns.
  3. 3Inspect the CAN3 wiring between the MCM and the actuator for damage.
  4. 4Remove the EGR valve and inspect it for carbon and sticking.
  5. 5Check the EGR delta pressure sensor and the cooler for leaks and plugging.

Causes

  • EGR valve stuck with carbon or a failed actuator motor
  • Actuator connector or CAN wiring damaged
  • Low supply voltage to the actuator
  • EGR cooler or delta pressure sensor problem

Most common here: real condition (10 of 29)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A loss of power, rough running, high smoke or a derate, and the check-engine lamp.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.