EF Logo

Cummins · Engine brake

Cummins Engine brake solenoid drivers and lamp fault codes

The compression brake has solenoid drivers that the ECM switches to apply braking, and a lamp that shows when the brake is active. The ECM checks each driver circuit for shorts and opens.

FaultCheck2182Cummins · Engine brake actuator driver 1
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 2182 to 6422 are all about the engine brake solenoid drivers and lamp. The most common failure type is shorted high (5 of 10); none needs an immediate stop. Start with this check: measure each brake solenoid coil resistance at the connector and compare with the manual.

How urgent are they?

None of the 10 codes here means stop now; all 10 can wait until the shift ends, but find the cause before the next one.

  • Check soon10

What should I check first?

Measure each brake solenoid coil resistance at the connector and compare with the manual

Shared checks

10 of 10

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Engine brake actuator driver 11 code

    • Cummins 2182Engine brake actuator driver 1: Voltage high

      The ECM reads the engine brake actuator driver 1 above its allowed voltage band.· Shorted high
      Check soon

      Causes

      • Short to a 5 V reference or a battery wire in the harness to the engine brake actuator driver 1
      • Open or high-resistance return wire that lets the signal float high
      • Water or corrosion in the connector bridging two pins together

      Checks

      1. 1Key on, unplug the engine brake actuator driver 1 and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
      2. 2Jumper the signal wire of the engine brake actuator driver 1 to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
      3. 3Check continuity and resistance of the return wire from the engine brake actuator driver 1 back to the ECM
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • Engine brake actuator driver output 2 circuit4 codes

    • Cummins 2363Engine brake actuator driver output 2 circuit: Voltage low / shorted low

      Same failure as 2183 on the engine brake actuator driver output 2 circuit: the same fault condition as 2183, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 2183, applied to the engine brake actuator driver output 2 circuit
      • Wiring or connector problem local to the engine brake actuator driver output 2 circuit

      Checks

      1. 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
      2. 2Work through the checks listed for 2183, starting at the engine brake actuator driver output 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine brake actuator driver output 2 circuit - voltage low (shorted to a low source)

    • Cummins 2367Engine brake actuator driver output 2 circuit: Voltage high / shorted high

      Same failure as 2182 on the engine brake actuator driver output 2 circuit: the same fault condition as 2182, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 2182, applied to the engine brake actuator driver output 2 circuit
      • Wiring or connector problem local to the engine brake actuator driver output 2 circuit

      Checks

      1. 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
      2. 2Work through the checks listed for 2182, starting at the engine brake actuator driver output 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine brake actuator driver output 2 circuit - voltage high (shorted to a high source)

    • Cummins 6421Engine brake actuator driver output 2 circuit: Voltage high / shorted high

      Same failure as 2182 on the engine brake actuator driver output 2 circuit: the same fault condition as 2182, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 2182, applied to the engine brake actuator driver output 2 circuit
      • Wiring or connector problem local to the engine brake actuator driver output 2 circuit

      Checks

      1. 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
      2. 2Work through the checks listed for 2182, starting at the engine brake actuator driver output 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine brake actuator driver output 2 circuit - voltage high (shorted to a high source)

    • Cummins 6422Engine brake actuator driver output 2 circuit: Voltage low / shorted low

      Same failure as 2183 on the engine brake actuator driver output 2 circuit: the same fault condition as 2183, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 2183, applied to the engine brake actuator driver output 2 circuit
      • Wiring or connector problem local to the engine brake actuator driver output 2 circuit

      Checks

      1. 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
      2. 2Work through the checks listed for 2183, starting at the engine brake actuator driver output 2 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine brake actuator driver output 2 circuit - voltage low (shorted to a low source)

  • Engine brake active lamp2 codes

    • Cummins 4293Engine brake active lamp: Voltage high / shorted high

      Same failure as 2182 on the engine brake active lamp: the same fault condition as 2182, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 2182, applied to the engine brake active lamp
      • Wiring or connector problem local to the engine brake active lamp

      Checks

      1. 1Check the lamp, its bulb and its circuit at the dash.
      2. 2Work through the checks listed for 2182, starting at the engine brake active lamp and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine brake active lamp - voltage high (shorted to a high source)

    • Cummins 4294Engine brake active lamp: Voltage low / shorted low

      Same failure as 2183 on the engine brake active lamp: the same fault condition as 2183, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 2183, applied to the engine brake active lamp
      • Wiring or connector problem local to the engine brake active lamp

      Checks

      1. 1Check the lamp, its bulb and its circuit at the dash.
      2. 2Work through the checks listed for 2183, starting at the engine brake active lamp and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine brake active lamp - voltage low (shorted to a low source)

  • Engine brake actuator driver 1 circuit2 codes

    • Cummins 6418Engine brake actuator driver 1 circuit: Voltage high / shorted high

      Same failure as 2182 on the engine brake actuator driver 1 circuit: the same fault condition as 2182, reported for this part.· Shorted high
      Check soon

      Causes

      • Same causes as 2182, applied to the engine brake actuator driver 1 circuit
      • Wiring or connector problem local to the engine brake actuator driver 1 circuit

      Checks

      1. 1Check the harness and solenoid connector for the first brake circuit and compare with driver output 2.
      2. 2Work through the checks listed for 2182, starting at the engine brake actuator driver 1 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine brake actuator driver 1 circuit - voltage high (shorted to a high source)

    • Cummins 6419Engine brake actuator driver 1 circuit: Voltage low / shorted low

      Same failure as 2183 on the engine brake actuator driver 1 circuit: the same fault condition as 2183, reported for this part.· Shorted low
      Check soon

      Causes

      • Same causes as 2183, applied to the engine brake actuator driver 1 circuit
      • Wiring or connector problem local to the engine brake actuator driver 1 circuit

      Checks

      1. 1Check the harness and solenoid connector for the first brake circuit and compare with driver output 2.
      2. 2Work through the checks listed for 2183, starting at the engine brake actuator driver 1 circuit and its connector
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine brake actuator driver 1 circuit - voltage low (shorted to a low source)

  • Other codes1 code

    • Cummins 2183Engine brake solenoid driver shorted low or driver voltage low

      The ECM reads the engine brake solenoid driver shorted low or driver voltage low below its allowed voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire to the engine brake solenoid driver shorted low or driver voltage low rubbed through and shorted to ground or to the engine block
      • Open 5 V reference or open signal wire that lets the input drop to zero
      • Corroded or backed-out pin in the engine brake solenoid driver shorted low or driver voltage low connector

      Checks

      1. 1Key on, unplug the engine brake solenoid driver shorted low or driver voltage low and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
      2. 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
      3. 3Measure resistance from the engine brake solenoid driver shorted low or driver voltage low signal wire to ground with the ECM unplugged to find a short
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Measure each brake solenoid coil resistance at the connector and compare with the manual
  2. 2Test the driver wiring for shorts to ground and battery with the connector unplugged
  3. 3Inspect the valve cover connector and harness for oil, chafing and corrosion
  4. 4Check the brake enable switches and settings in INSITE before replacing hardware
  5. 5Check the brake lamp circuit and its fuse

Causes

  • Open, shorted or chafed brake solenoid wiring under the valve cover
  • Brake solenoid coil failed
  • Connector at the valve cover corroded or loose
  • Lamp circuit or cluster fault

Most common here: shorted high (5 of 10)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: The engine brake may not work, may work on fewer cylinders or may not turn on its dash lamp.

Brake and steering faults are a safety issue on site. Chock the machine and keep it parked until the fault is found and the brakes are tested.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.