Cummins · Engine brake
Cummins Engine brake solenoid drivers and lamp fault codes
The compression brake has solenoid drivers that the ECM switches to apply braking, and a lamp that shows when the brake is active. The ECM checks each driver circuit for shorts and opens.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 2182 to 6422 are all about the engine brake solenoid drivers and lamp. The most common failure type is shorted high (5 of 10); none needs an immediate stop. Start with this check: measure each brake solenoid coil resistance at the connector and compare with the manual.
How urgent are they?
None of the 10 codes here means stop now; all 10 can wait until the shift ends, but find the cause before the next one.
- Check soon10
What should I check first?
Measure each brake solenoid coil resistance at the connector and compare with the manual
Shared checks10 of 10
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Engine brake actuator driver 11 code
Cummins 2182Engine brake actuator driver 1: Voltage high
The ECM reads the engine brake actuator driver 1 above its allowed voltage band. That points to a short to a 5 V or battery wire, a lost return, or a failed part, rather than a real change in what it measures.· Shorted highShorted highCheck soonCauses
- Short to a 5 V reference or a battery wire in the harness to the engine brake actuator driver 1
- Open or high-resistance return wire that lets the signal float high
- Water or corrosion in the connector bridging two pins together
Checks
- 1Key on, unplug the engine brake actuator driver 1 and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
- 2Jumper the signal wire of the engine brake actuator driver 1 to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
- 3Check continuity and resistance of the return wire from the engine brake actuator driver 1 back to the ECM
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Engine brake actuator driver output 2 circuit4 codes
Cummins 2363Engine brake actuator driver output 2 circuit: Voltage low / shorted low
Same failure as 2183 on the engine brake actuator driver output 2 circuit: the same fault condition as 2183, reported for this part. Driver output 2 operates the second engine brake solenoid circuit, which controls the other part of the braking power.· Shorted lowShorted lowCheck soonCauses
- Same causes as 2183, applied to the engine brake actuator driver output 2 circuit
- Wiring or connector problem local to the engine brake actuator driver output 2 circuit
Checks
- 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
- 2Work through the checks listed for 2183, starting at the engine brake actuator driver output 2 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine brake actuator driver output 2 circuit - voltage low (shorted to a low source)
Cummins 2367Engine brake actuator driver output 2 circuit: Voltage high / shorted high
Same failure as 2182 on the engine brake actuator driver output 2 circuit: the same fault condition as 2182, reported for this part. Driver output 2 operates the second engine brake solenoid circuit, which controls the other part of the braking power.· Shorted highShorted highCheck soonCauses
- Same causes as 2182, applied to the engine brake actuator driver output 2 circuit
- Wiring or connector problem local to the engine brake actuator driver output 2 circuit
Checks
- 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
- 2Work through the checks listed for 2182, starting at the engine brake actuator driver output 2 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine brake actuator driver output 2 circuit - voltage high (shorted to a high source)
Cummins 6421Engine brake actuator driver output 2 circuit: Voltage high / shorted high
Same failure as 2182 on the engine brake actuator driver output 2 circuit: the same fault condition as 2182, reported for this part. Driver output 2 operates the second engine brake solenoid circuit, which controls the other part of the braking power.· Shorted highShorted highCheck soonCauses
- Same causes as 2182, applied to the engine brake actuator driver output 2 circuit
- Wiring or connector problem local to the engine brake actuator driver output 2 circuit
Checks
- 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
- 2Work through the checks listed for 2182, starting at the engine brake actuator driver output 2 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine brake actuator driver output 2 circuit - voltage high (shorted to a high source)
Cummins 6422Engine brake actuator driver output 2 circuit: Voltage low / shorted low
Same failure as 2183 on the engine brake actuator driver output 2 circuit: the same fault condition as 2183, reported for this part. Driver output 2 operates the second engine brake solenoid circuit, which controls the other part of the braking power.· Shorted lowShorted lowCheck soonCauses
- Same causes as 2183, applied to the engine brake actuator driver output 2 circuit
- Wiring or connector problem local to the engine brake actuator driver output 2 circuit
Checks
- 1Check the harness and solenoid connector for the second brake circuit and compare with driver 1.
- 2Work through the checks listed for 2183, starting at the engine brake actuator driver output 2 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine brake actuator driver output 2 circuit - voltage low (shorted to a low source)
Engine brake active lamp2 codes
Cummins 4293Engine brake active lamp: Voltage high / shorted high
Same failure as 2182 on the engine brake active lamp: the same fault condition as 2182, reported for this part. The engine brake active lamp shows the driver when the engine brake is working.· Shorted highShorted highCheck soonCauses
- Same causes as 2182, applied to the engine brake active lamp
- Wiring or connector problem local to the engine brake active lamp
Checks
- 1Check the lamp, its bulb and its circuit at the dash.
- 2Work through the checks listed for 2182, starting at the engine brake active lamp and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine brake active lamp - voltage high (shorted to a high source)
Cummins 4294Engine brake active lamp: Voltage low / shorted low
Same failure as 2183 on the engine brake active lamp: the same fault condition as 2183, reported for this part. The engine brake active lamp shows the driver when the engine brake is working.· Shorted lowShorted lowCheck soonCauses
- Same causes as 2183, applied to the engine brake active lamp
- Wiring or connector problem local to the engine brake active lamp
Checks
- 1Check the lamp, its bulb and its circuit at the dash.
- 2Work through the checks listed for 2183, starting at the engine brake active lamp and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine brake active lamp - voltage low (shorted to a low source)
Engine brake actuator driver 1 circuit2 codes
Cummins 6418Engine brake actuator driver 1 circuit: Voltage high / shorted high
Same failure as 2182 on the engine brake actuator driver 1 circuit: the same fault condition as 2182, reported for this part. Driver 1 operates the first engine brake solenoid circuit, which controls part of the braking power.· Shorted highShorted highCheck soonCauses
- Same causes as 2182, applied to the engine brake actuator driver 1 circuit
- Wiring or connector problem local to the engine brake actuator driver 1 circuit
Checks
- 1Check the harness and solenoid connector for the first brake circuit and compare with driver output 2.
- 2Work through the checks listed for 2182, starting at the engine brake actuator driver 1 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine brake actuator driver 1 circuit - voltage high (shorted to a high source)
Cummins 6419Engine brake actuator driver 1 circuit: Voltage low / shorted low
Same failure as 2183 on the engine brake actuator driver 1 circuit: the same fault condition as 2183, reported for this part. Driver 1 operates the first engine brake solenoid circuit, which controls part of the braking power.· Shorted lowShorted lowCheck soonCauses
- Same causes as 2183, applied to the engine brake actuator driver 1 circuit
- Wiring or connector problem local to the engine brake actuator driver 1 circuit
Checks
- 1Check the harness and solenoid connector for the first brake circuit and compare with driver output 2.
- 2Work through the checks listed for 2183, starting at the engine brake actuator driver 1 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine brake actuator driver 1 circuit - voltage low (shorted to a low source)
Other codes1 code
Cummins 2183Engine brake solenoid driver shorted low or driver voltage low
The ECM reads the engine brake solenoid driver shorted low or driver voltage low below its allowed voltage band. That points to a short to ground, an open supply or signal wire, or a failed part, not necessarily a real low value.· Shorted lowShorted lowCheck soonCauses
- Signal wire to the engine brake solenoid driver shorted low or driver voltage low rubbed through and shorted to ground or to the engine block
- Open 5 V reference or open signal wire that lets the input drop to zero
- Corroded or backed-out pin in the engine brake solenoid driver shorted low or driver voltage low connector
Checks
- 1Key on, unplug the engine brake solenoid driver shorted low or driver voltage low and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
- 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
- 3Measure resistance from the engine brake solenoid driver shorted low or driver voltage low signal wire to ground with the ECM unplugged to find a short
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Measure each brake solenoid coil resistance at the connector and compare with the manual
- 2Test the driver wiring for shorts to ground and battery with the connector unplugged
- 3Inspect the valve cover connector and harness for oil, chafing and corrosion
- 4Check the brake enable switches and settings in INSITE before replacing hardware
- 5Check the brake lamp circuit and its fuse
Causes
- Open, shorted or chafed brake solenoid wiring under the valve cover
- Brake solenoid coil failed
- Connector at the valve cover corroded or loose
- Lamp circuit or cluster fault
Most common here: shorted high (5 of 10)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: The engine brake may not work, may work on fewer cylinders or may not turn on its dash lamp.
Brake and steering faults are a safety issue on site. Chock the machine and keep it parked until the fault is found and the brakes are tested.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.