EF Logo

Cummins · Electrical

Cummins Battery, charging and ECM power supply fault codes

The ECM measures battery voltage and, on some engines, a second battery and the charging system voltage. The starting-lighting-ignition battery pack state of charge is reported to the ECM by the vehicle.

More about these parts

The ECM needs a stable supply from the battery and an ignition feed.

FaultCheck1117Cummins · Battery, charging and ECM power supply
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 441 to 8346 are all about the battery, charging and ECM power supply. The most common failure type is real condition (7 of 18); none needs an immediate stop. Start with this check: measure battery voltage at rest and while cranking with a good voltmeter.

How urgent are they?

None of the 18 codes here means stop now; 15 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Check soon15
  • Info3

What should I check first?

Measure battery voltage at rest and while cranking with a good voltmeter

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Battery 2 voltage2 codes

    • Cummins 477Battery 2 voltage: Below normal· moderately severe

      The battery 2 voltage is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live battery 2 voltage with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Battery 2 voltage - below normal - moderately severe

    • Cummins 478Battery 2 voltage: Above normal· moderately severe

      The battery 2 voltage is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live battery 2 voltage with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Battery 2 voltage - above normal - moderately severe

  • Electrical charging system voltage1 code

    • Cummins 596Electrical charging system voltage: Above normal· moderately severe

      The electrical charging system voltage is above its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live electrical charging system voltage with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Electrical charging system voltage - above normal - moderately severe

  • Power relay driver circuit1 code

    • Cummins 1777Power relay driver circuit: Voltage low / shorted low

      The ECM sees the power relay driver circuit drive circuit with voltage below the expected level.· Shorted low
      Check soon

      Causes

      • Output wire shorted to ground or chafed through to the chassis
      • Component winding shorted internally
      • Connector corroded and bridging the pins

      Checks

      1. 1Unplug the power relay driver circuit connector and measure the output pin to ground; a short here means the harness is at fault
      2. 2Measure the component resistance across its pins; a very low reading means a shorted winding
      3. 3Inspect the connector for moisture and bridged terminals
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Power relay driver circuit - voltage low (shorted to a low source)

  • ECU power output supply voltage 12 codes

    • Cummins 1938ECU power output supply voltage 1: Below normal· moderately severe

      The ECU power output supply voltage 1 is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live ECU power output supply voltage 1 with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:ECU power output supply voltage 1 - below normal - moderately severe

    • Cummins 1941ECU power output supply voltage 1: Voltage low / shorted low

      The ECM sees the ECU power output supply voltage 1 signal circuit below its normal voltage range, which points to a short to ground or a failed input rather than a real condition.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground
      • Failed input or damaged connector at the module

      Checks

      1. 1Check the wiring and connector for shorts to ground
      2. 2Compare the reading with the related signal in INSITE
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:ECU power output supply voltage 1 - voltage low (shorted to a low source)

  • Battery 1 voltage3 codes

    • Cummins 3724Battery 1 voltage: Below normal· least severe

      The battery 1 voltage is below its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live battery 1 voltage with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Battery 1 voltage - below normal - least severe

    • Cummins 6256Battery 1 voltage: Above normal· least severe

      The battery 1 voltage is above its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too high because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live battery 1 voltage with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Battery 1 voltage - above normal - least severe

    • Cummins 6257Battery 1 voltage: Below normal· least severe

      The battery 1 voltage is below its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live battery 1 voltage with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Battery 1 voltage - below normal - least severe

  • Maintain ECU power lamp2 codes

    • Cummins 4951Maintain ECU power lamp: Voltage high / shorted high

      The ECM sees the maintain ECU power lamp drive circuit with voltage above the expected level.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery or a switched power feed
      • Open ground or return path on the component
      • Component winding failed or its connector damaged

      Checks

      1. 1Unplug the maintain ECU power lamp connector, key on, and measure the output pin to ground; battery voltage with nothing connected points to a short to power
      2. 2Inspect the harness for a rubbed wire or damaged splice touching a power feed
      3. 3Measure the component resistance across its pins to rule out an open winding
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Maintain ECU power lamp - voltage high (shorted to a high source)

    • Cummins 4952Maintain ECU power lamp: Voltage low / shorted low

      The ECM sees the maintain ECU power lamp drive circuit with voltage below the expected level.· Shorted low
      Check soon

      Causes

      • Output wire shorted to ground or chafed through to the chassis
      • Component winding shorted internally
      • Connector corroded and bridging the pins

      Checks

      1. 1Unplug the maintain ECU power lamp connector and measure the output pin to ground; a short here means the harness is at fault
      2. 2Measure the component resistance across its pins; a very low reading means a shorted winding
      3. 3Inspect the connector for moisture and bridged terminals
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Maintain ECU power lamp - voltage low (shorted to a low source)

  • SLI battery pack state of charge2 codes

    • Cummins 8343SLI battery pack state of charge: Abnormal update rate

      The ECM is not receiving fresh data for the SLI battery pack state of charge at the expected rate.· Lost message
      Check soon

      Causes

      • Data link wiring fault or a poor connector contact
      • The module that sends the message is offline or failing
      • Power or ground problem at the sending module

      Checks

      1. 1Look for other modules reporting timeouts to find where the link is broken
      2. 2Check the data link wiring, connectors and terminators
      3. 3Read the sending module for its own codes
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Cummins 8346SLI battery pack state of charge: Out of calibration

      The ECM reports the SLI battery pack state of charge as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Part or controller
      Check soon

      Causes

      • Parameter set for a feature that is not fitted
      • Wrong or outdated calibration in the ECM
      • Source module sending an invalid value

      Checks

      1. 1Compare the ECM parameters with the vehicle equipment
      2. 2Reflash the ECM with the correct calibration
      3. 3Read the source module for its own codes
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Other codes5 codes

    • Cummins 441Battery voltage low· moderately severe

      The system voltage the ECM sees is below the normal range while the engine is running or the key is on.· Shorted low
      Check soon

      Causes

      • Weak or discharged batteries
      • Loose or corroded battery or ground cables
      • Alternator not charging

      Checks

      1. 1Measure battery voltage at rest, cranking and running
      2. 2Check the battery terminals and ground straps for corrosion and loose connections
      3. 3Test the alternator output at the battery with the engine running at fast idle
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Battery voltage low - moderately severe

    • Cummins 442Battery voltage high· moderately severe

      The system voltage is above the normal range, which can damage electronics.· Shorted high
      Check soon

      Causes

      • Alternator regulator failed
      • Wrong charging voltage on a jump start
      • Loose sense wire at the alternator

      Checks

      1. 1Measure the alternator output voltage at the battery
      2. 2Check the alternator and regulator output with a meter at the battery under different loads
      3. 3Check the alternator sense wire for a loose or corroded connection that causes overcharging
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Battery voltage high - moderately severe

    • Cummins 597Charging system voltage low· moderately severe

      The charging system voltage is below the allowed limit while the engine is running.· Shorted low
      Check soon

      Causes

      • Alternator not charging
      • Slipping or broken drive belt
      • Battery or ground cable corroded

      Checks

      1. 1Measure the voltage at the batteries with the engine running
      2. 2Check the alternator drive belt for slipping, glazing or damage
      3. 3Check the battery cables and ground connections for corrosion and voltage drop
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Charging system voltage low - moderately severe

    • Cummins 598Charging system voltage very low· most severe

      The charging system voltage is critically low.· Other
      Check soon

      Causes

      • Alternator failed
      • Belt off or broken
      • Main charge cable disconnected

      Checks

      1. 1Check the alternator drive belt first because a broken belt gives a very low charging voltage
      2. 2Measure the batteries and the alternator output
      3. 3Check the main charge cable and the fuse links for an open circuit
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:Charging system voltage very low - most severe

    • Cummins 1117Power supply lost with ignition on

      The ECM loses its battery power for a moment while the ignition is on.· Other
      Check soon

      Causes

      • Loose or corroded battery terminal or ground strap
      • ECM power fuse or relay with poor contact
      • ECM power connector pin loose, corroded or backed out
      • Weak battery or a loose alternator that drops system voltage

      Checks

      1. 1Check battery terminals and the main ground strap at the block and chassis for tightness and corrosion
      2. 2Measure battery voltage with the engine off and with the engine running; both should be steady at a normal 12 V / 24 V system level
      3. 3Wiggle-test the ECM power connector with the key on and watch for a drop in voltage
      4. 4Inspect the ECM power fuse, relay and holder for heat damage
      5. 5Check the harness ground to the ECM and the battery cable for hidden corrosion under the insulation
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Measure battery voltage at rest and while cranking with a good voltmeter
  2. 2Check the data link between the battery monitor and the ECM for missing messages
  3. 3Check the ECM fuses and the ignition feed with a voltmeter under load
  4. 4Check alternator output with the engine running and loads on
  5. 5Verify the monitor reading against a voltmeter at the battery terminals
  6. 6Inspect the battery and ECM ground connections for corrosion and voltage drop
  7. 7Clean and tighten the battery terminals and ground straps

Causes

  • Weak or sulphated batteries
  • Battery monitor module fault
  • Loose or corroded battery, ground or ignition feed
  • Alternator or regulator failure

Most common here: real condition (7 of 18)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: Starting problems, dim lights or random warnings if low, and electronic damage risk if high.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.