Bobcat · Filters
Bobcat Air, hydraulic and fuel filters fault codes
The restriction switches on the air cleaner, the hydraulic return and charge filters and the fuel filter report a clogged element or a broken switch circuit to the controller. Each filter has its own switch, so a code names which filter needs service, or which switch circuit has failed.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes 01-16 to M9145 are all about the air, hydraulic and fuel filters. The most common failure type is lost message (9 of 25); none needs an immediate stop. Start with this check: look at the element first: change it if it is dirty or has passed its service interval, then clear the code and see whether it returns.
How urgent are they?
None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.
- Check soon25
What should I check first?
Look at the element first: change it if it is dirty or has passed its service interval, then clear the code and see whether it returns.
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat 01-16Air filter not connected
The air filter switch circuit is open on older numeric-code Bobcat loaders. The controller cannot monitor air filter restriction while this is active, so the filter must be checked by hand.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector
- Switch plug off or not latched
- Switch failed open
Checks
- 1Check the connector at the air cleaner housing is seated and its locking tab is engaged
- 2Check that the switch is screwed in firmly and the seal is not leaking air
- 3Wiggle the harness along the air cleaner bracket with the key on and watch whether the code sets or clears
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat 01-17Air filter plugged
The air filter restriction switch says the filter is clogged. Left alone it leads to smoke and loss of power from the starved engine.· Real conditionReal conditionCheck soonCauses
- Switch stuck in the closed position
- Pre-cleaner or dust ejector blocked
- Primary filter element loaded with dust
- Intake hose collapsed or clamp crushed
Checks
- 1Check that the replacement element is the correct part number and sits fully in its seal
- 2Pull the primary air filter element and inspect it; replace it if it is loaded with dust or oil
- 3Check the intake hose between the cleaner and the turbo for collapse or a crushed clamp
- 4Check the service history; a filter that has not been changed for a long season is a likely cause
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat 02-16Hydraulic charge filter not connected
The charge filter switch circuit is open. The controller cannot monitor the filter while this is active, so service the filter by hours.· Open circuitOpen circuitCheck soonCauses
- Wire broken at the plug or the controller side
- Switch plug loose at the charge filter
- Backed-out pin
Checks
- 1Check the connector on the charge filter housing is fully seated and locked
- 2Move the harness near the charge filter bracket while monitoring the code
- 3Test the switch at its pins to confirm it reads the correct state when the filter is clean
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat 02-17Hydraulic charge filter plugged
The charge filter restriction switch indicates a clogged filter. Cold, thick oil can trigger it briefly, so check whether it only appears on a cold start.· Lost messageLost messageCheck soonCauses
- Charge filter overdue
- Contaminated oil
- Oil still cold and thick
Checks
- 1Run the machine until the oil is warm and see whether the code clears; if not, change the charge filter
- 2Check the sump or reservoir for sludge or water that clogs the element quickly
- 3Check the charge pressure at the test port to see whether the restriction is affecting drive
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat 10-16Hydraulic implement filter not connected
The controller reports the hydraulic implement filter as not connected. The circuit looks open, so the controller cannot read or drive it until the connection is restored.· Open circuitOpen circuitCheck soonCauses
- Plug off or not latched
- Pin pushed out of the connector body
- Wire broken near the part
Checks
- 1Look at the plug on the hydraulic implement filter and reseat it until the lock clicks
- 2Check each pin in the plug for push-out or bent contacts
- 3Test continuity of the wires between the plug and the controller
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat 10-17Hydraulic implement filter plugged
The hydraulic implement filter reports a plugged element. Flow is restricted and the engine or hydraulics can lose power, or the machine may derate.· Lost messageLost messageCheck soonCauses
- Element full of dirt or water
- Service overdue
- Switch or sensor reading wrongly
Checks
- 1Replace the element and check what plugged it
- 2Check the sensor connector and wiring for a false reading
- 3Clear the code and test under load
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M0116Air filter switch not connected
The controller sees no air restriction switch on the engine air cleaner circuit. The loader still runs but cannot warn you when the filter clogs.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector
- Corrosion in the switch plug
- Wire to the switch broken near the air cleaner
Checks
- 1Look for pushed-back pins or green corrosion inside the plug and spray with contact cleaner
- 2Measure wire continuity between the switch plug and the controller with the key off; each wire should show no break
- 3Compare the switch with a known good one from a similar machine if available
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M0117Air filter plugged
The air filter restriction switch is telling the controller the intake is clogged. Left alone it leads to smoke, power loss and a derate (see M0144, M0145).· Real conditionReal conditionCheck soonCauses
- Switch stuck in the closed position
- Wrong or poor quality filter fitted
- Pre-cleaner or dust ejector blocked
- Intake hose collapsed or clamp crushed
Checks
- 1Clean the dust ejector and pre-cleaner so they can pass dirt out of the housing
- 2Look for trash or a plastic bag drawn against the intake screen or snorkel
- 3Test the switch with a meter while the filter is out; it should open once the restriction is gone
- 4Clear the code after the filter job and run at high idle to confirm it stays away
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M0144Air filter derate level 1
The air filter has stayed restricted long enough that the controller has started to reduce engine power. Change the filter before it moves on to the second stage.· Real conditionReal conditionCheck soonCauses
- Intake pipe partly blocked
- Filter canister seal leaking inside
- Dust ejector valve jammed shut
Checks
- 1Measure restriction at the air cleaner outlet if a gauge is available, and compare to the service limit
- 2Open the dust ejector valve and clear it so dust drops out of the housing
- 3Check the canister lid and seal; a poor seal lets dust past and loads the filter fast
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M0145Air filter derate level 2
Air restriction is now severe and the controller has cut engine power further. Running on risks damaging the engine.· Real conditionReal conditionCheck soonCauses
- Blocked air intake screen
- Restriction switch failed closed
- Debris inside the turbo inlet
Checks
- 1Look through the intake pipe for debris; a rag or plastic sheet can block the opening
- 2Look for coolant or oil in the intake that would show a leak upstream of the turbo
- 3Check the turbo compressor inlet for foreign material or oil
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M0216Hydraulic/hydrostatic filter not connected
The controller cannot see the switch on the hydraulic charge or return filter. Filter condition is not being monitored while the code is active.· Open circuitOpen circuitCheck soonCauses
- Switch failed open
- Broken wire in the filter switch harness
- Corroded pins
Checks
- 1Inspect the pins for green crust and the seal for water inside the plug
- 2Check continuity of both switch wires to the controller with the key off
- 3Compare with a known good switch or swap the switch from another filter port to check the wire
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M0217Hydraulic/hydrostatic filter plugged
The switch on the hydraulic filter shows a blocked or heavily loaded filter. Cold, thick oil can also trigger it briefly.· Lost messageLost messageCheck soonCauses
- Cold oil too thick to flow through
- Damaged filter bypass
- Switch fault giving a false closure
- Dirty or degraded hydraulic oil
Checks
- 1Inspect the filter head bypass valve for debris that holds it open or shut
- 2Test the switch with a meter; it should be open when the element is clean
- 3Replace the filter element and note the colour and debris on the old one
- 4Clear the code after the change and run the hydraulics hot to confirm it stays away
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M1016Hydraulic charge filter not connected
The charge filter restriction switch circuit is open. The controller cannot tell if the charge filter is clogged.· Open circuitOpen circuitCheck soonCauses
- Corroded connector
- Wire broken at the plug or the controller side
- Failed switch
Checks
- 1Inspect the plug for water and pushed-back pins
- 2Check the harness for damage where it passes the hydrostatic pump housing
- 3Check wire continuity between the switch plug and the controller with the key off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M1017Hydraulic charge filter plugged
The charge filter restriction switch has closed, so the charge filter is clogged. Low charge pressure can follow and starve the drive pumps.· Lost messageLost messageCheck soonCauses
- Switch failed closed
- Oil still cold and thick
- Filter element collapsed
Checks
- 1Inspect the filter housing bypass valve for damage or debris
- 2Test the switch for a closed state with the filter removed; it should open when the pressure drop is gone
- 3Replace the charge filter with the correct part and check the old one for debris
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat P1060-16Air filter out of range low
The air filter signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Open signal wire or missing supply
- Sensor failed low
Checks
- 1Check the supply voltage at the air filter plug with the key on
- 2Look at the live reading on the display and see if it sits at the bottom of its scale
- 3Test the signal wire to ground with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat P1060-17Air filter out of range high
The air filter signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· OtherOtherCheck soonCauses
- Signal wire shorted to supply
- Open sensor ground giving a floating high signal
- Sensor failed high
Checks
- 1Check the ground wire of the air filter for continuity
- 2Look at the live reading on the display and see if it sits at the top of its scale
- 3Test the signal wire for stray voltage with the plug off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat P1062-00Air filter plugged
The air filter reports a plugged element. Flow is restricted and the engine or hydraulics can lose power, or the machine may derate.· Lost messageLost messageCheck soonCauses
- Element full of dirt or water
- Service overdue
- Switch or sensor reading wrongly
Checks
- 1Replace the element and check what plugged it
- 2Check the sensor connector and wiring for a false reading
- 3Clear the code and test under load
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat P1063-00Air filter plugged
The air filter reports a plugged element. Flow is restricted and the engine or hydraulics can lose power, or the machine may derate.· Lost messageLost messageCheck soonCauses
- Element full of dirt or water
- Service overdue
- Switch or sensor reading wrongly
Checks
- 1Replace the element and check what plugged it
- 2Check the sensor connector and wiring for a false reading
- 3Clear the code and test under load
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat C1093-00Hydraulic case drain filter switch plugged
The hydraulic case drain filter switch reports a plugged element. Flow is restricted and the engine or hydraulics can lose power, or the machine may derate.· Lost messageLost messageCheck soonCauses
- Element full of dirt or water
- Service overdue
- Switch or sensor reading wrongly
Checks
- 1Replace the element and check what plugged it
- 2Check the sensor connector and wiring for a false reading
- 3Clear the code and test under load
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M9111Fuel filter extremely plugged
The fuel filter reports a plugged element. Flow is restricted and the engine or hydraulics can lose power, or the machine may derate.· Lost messageLost messageCheck soonCauses
- Element full of dirt or water
- Service overdue
- Switch or sensor reading wrongly
Checks
- 1Replace the element and check what plugged it
- 2Check the sensor connector and wiring for a false reading
- 3Clear the code and test under load
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M9117Fuel filter plugged
The fuel filter reports a plugged element. Flow is restricted and the engine or hydraulics can lose power, or the machine may derate.· Lost messageLost messageCheck soonCauses
- Element full of dirt or water
- Service overdue
- Switch or sensor reading wrongly
Checks
- 1Replace the element and check what plugged it
- 2Check the sensor connector and wiring for a false reading
- 3Clear the code and test under load
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat H9144Fuel filter derate level 1
The fuel filter has set derate level 1, meaning the controller cuts engine power in a first step to protect the engine. Fix the restriction before it steps up to level 2.· Real conditionReal conditionCheck soonCauses
- Element or line restricted
- Service overdue
- Sensor reading a false restriction
Checks
- 1Check the service state of the part this code names
- 2Replace the element if it is dirty or overdue
- 3Clear the code and watch whether it returns under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M9144Fuel filter derate level 1
The fuel filter has set derate level 1, meaning the controller cuts engine power in a first step to protect the engine. Fix the restriction before it steps up to level 2.· Real conditionReal conditionCheck soonCauses
- Element or line restricted
- Service overdue
- Sensor reading a false restriction
Checks
- 1Check the service state of the part this code names
- 2Replace the element if it is dirty or overdue
- 3Clear the code and watch whether it returns under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat H9145Fuel filter derate level 2
The fuel filter has set derate level 2, the second and stronger power cut. The restriction is severe and the machine will work well below normal power.· Real conditionReal conditionCheck soonCauses
- Element or line badly blocked
- Service well overdue
- Sensor stuck reading blocked
Checks
- 1Replace the filter element and bleed the system as the manual describes
- 2Check the supply line for kinks or collapse
- 3Clear the code and test under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat M9145Fuel filter derate level 2
The fuel filter has set derate level 2, the second and stronger power cut. The restriction is severe and the machine will work well below normal power.· Real conditionReal conditionCheck soonCauses
- Element or line badly blocked
- Service well overdue
- Sensor stuck reading blocked
Checks
- 1Replace the filter element and bleed the system as the manual describes
- 2Check the supply line for kinks or collapse
- 3Clear the code and test under load
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Shared checks
Checks, in order
- 1Look at the element first: change it if it is dirty or has passed its service interval, then clear the code and see whether it returns.
- 2Unplug the filter switch and check the connector for water, green corrosion and pins pushed back in the shell.
- 3Check continuity of the switch wires back to the controller connector, flexing the harness near the filter bracket as you go.
- 4Compare warm and cold behaviour: a warning that appears only on a cold start and clears when the oil warms is usually thick oil, not a blocked filter.
- 5Fit a known good switch if the wiring tests clean and the code stays active with a fresh element.
Causes
- Element clogged by dirt, so the switch is correctly reporting restriction
- Switch plug off, pin backed out or wire broken at the filter housing
- Switch itself failed open or stuck closed
- Wrong or cold-thick oil giving a false restriction reading at start-up
Most common here: lost message (9 of 25)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: A filter warning or service code appears on the panel.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.