EF Logo

Volvo/Mack · MID 128 engine ECU - module, data link and power

Volvo/Mack Starter relay output fault codes

The engine ECU drives the starter relay on some trucks. These codes cover its output circuit.

FaultCheckMID 128SID 39FMI 3Volvo/Mack · Starter relay output
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect the Premium Tech Tool or a J1939/J1587 scan tool to the diagnostic socket and read the codes for every module, not only the engine.

What do these codes mean?

Volvo/Mack codes MID 128 SID 39 FMI 3 and MID 128 SID 39 FMI 5 are all about the starter relay output. None needs an immediate stop. Start with this check: check the relay and its socket for burnt contacts, corrosion and a relay that does not click.

How urgent are they?

None of the 2 codes here means stop now; all 2 can wait until the shift ends, but find the cause before the next one.

  • Check soon2

What should I check first?

Check the relay and its socket for burnt contacts, corrosion and a relay that does not click

Shared checks

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Volvo/Mack MID 128 SID 39 FMI 3Starter relay output shorted high

    The engine starter relay output is shorted to positive, so the ECM sees a fault on the relay control circuit.· Shorted high
    Check soon

    Causes

    • Starter relay control circuit shorted to positive
    • Faulty starter relay
    • Harness fault

    Checks

    1. 1Check the starter relay and its socket for burn marks
    2. 2Measure the relay control wire voltage with the key off
    3. 3Swap in a known-good relay of the same type before you replace any parts
    4. 4Inspect the harness between the ECM and the relay for a short to power
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Volvo/Mack MID 128 SID 39 FMI 5Starter relay circuit open

    The engine starter relay control circuit is open, so the ECM cannot energise the relay and the starter does not engage.· Open circuit
    Check soon

    Causes

    • Open circuit in the starter relay control wire
    • Faulty starter relay
    • Connector fault

    Checks

    1. 1Check the relay and its socket for burn marks and loose pins
    2. 2Test continuity of the relay control wire to the ECM
    3. 3Swap in a known-good relay of the same type before you replace any parts
    4. 4Inspect the connector at the relay socket for damage, corrosion or looseness
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

Shared checks

Checks, in order

  1. 1Check the relay and its socket for burnt contacts, corrosion and a relay that does not click
  2. 2Check the wire between the ECU and the doser for a short to ground and to battery voltage
  3. 3Measure the relay coil resistance and compare it with the specified value to rule out an open coil
  4. 4Command the output with the scan tool and listen for the relay to click on each command

Causes

  • Relay failed
  • Wire shorted or open
  • Connector corroded

When to stop

You'll notice: The starter does not engage, or engages at the wrong time, and the truck may crank without starting.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.