Thermo King · Electric standby (SR-2/SR-3/SR-4)
Thermo King Electric standby motor, changeover and generator fault codes
This page covers electric standby operation: the standby motor and its power supply, diesel and electric changeover, and generator faults. On electric standby the compressor is driven by an electric motor from mains power.
More about these partsLess
Units with electric standby change automatically between diesel and electric power. On units with an on-board generator the controller checks the ground fault, the output current and frequency, and the voltage to frequency ratio.
Where this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
What do these codes mean?
Thermo King codes OL to 547 are all about the electric standby motor, changeover and generator. The most common failure type is real condition (4 of 18); 7 need an immediate stop. Start with this check: check each supply phase with a meter at the plug.
How urgent are they?
7 of 18 codes here mean stop now; 9 can wait until the shift ends, but find the cause before the next one; 2 are information only.
- Stop now7
- Check soon9
- Info2
What should I check first?
Check each supply phase with a meter at the plug
Shared checks18 of 18
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Thermo King OLElectric standby overload
The electric standby motor draws too much current. It stops to protect the winding.· Real conditionReal conditionStop nowCauses
- Compressor or fan binding
- Low supply voltage
Checks
- 1Check the supply voltage
- 2Check the motor current against the rating
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Thermo King tEPElectric standby motor thermal protection alarm
The thermal protection of the electric standby motor has tripped. The motor is too hot and stops.· OtherOtherStop nowCauses
- Motor overloaded or blocked
- Cooling blocked
Checks
- 1Let the motor cool and check the load
- 2Check the motor cooling
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King tP4Power supply thermal protection alarm
The thermal protection of the power supply has tripped. The unit stops until it cools.· OtherOtherStop nowCauses
- Overloaded supply
- Poor cooling
Checks
- 1Check the supply load and cooling
- 2Let it cool and restart
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 36Electric motor failed to run
In electric standby the controller asked the electric motor to run but it did not start or stopped. It is the standby equivalent of the engine failed to start alarm.· OtherOtherStop nowCauses
- Standby power cord or supply not live
- Motor contactor not closing
- Motor overload tripped
- Phase loss at the supply
Checks
- 1Confirm the supply voltage at the plug and breaker
- 2Check the contactor closes when run is commanded
- 3Check the overload relay for a trip and reset it
- 4Measure all three phases at the motor terminals
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 38Electric phase reversed
The controller detected the supply phase rotation is wrong for the standby motor, so the motor would run backwards. It blocks standby operation to protect the compressor.· OtherOtherStop nowCauses
- Supply wiring at the power plug or panel swapped
- Extension cord or adapter wired with wrong sequence
- Phase sensor failure
Checks
- 1Swap any two of the supply phases at the plug to correct rotation
- 2Use a phase rotation meter to confirm the sequence at the supply
- 3Check any adapters or cords used for wiring errors
- 4Retest the standby start after the swap and confirm the motor turns the right way
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 62Ammeter out of calibration
The current measurement for the electric standby motor is out of calibration. The unit cannot run safely on standby until it is fixed.· Part or controllerPart or controllerStop nowCauses
- Ammeter reading drifted
- Wiring fault
Checks
- 1Check the ammeter calibration with a clamp meter
- 2Recalibrate or replace the ammeter circuit
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 90Electric overload
The electric standby motor drew too much current and the overload tripped or the controller detected overload, shutting the motor down to protect it.· Real conditionReal conditionStop nowCauses
- Low supply voltage causing high current
- Blocked condenser or compressor seizure
- Motor winding fault
- Phase imbalance
Checks
- 1Measure the supply voltage at the unit while it runs under full load in electric mode
- 2Clean the condenser to reduce the compressor load that drives the current up
- 3Measure the current at each phase at the motor
- 4Check the overload relay setting against the motor plate and reset it
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Thermo King 91Check electric ready input
The electric ready input, a signal that confirms standby power is present and ready, is not behaving as expected when the unit is plugged in.· OtherOtherCheck soonCauses
- Standby supply not live or breaker off
- Electric ready relay or contactor not closing
- Wire to the input open or shorted
- Plug or receptacle damaged
Checks
- 1Confirm the standby supply is live at the power plug and the breaker is on
- 2Check the electric ready relay pulls in when the plug is live
- 3Test the wire from the relay to the controller input
- 4Inspect the plug and receptacle pins for burn marks
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 117Auto switch from diesel to electric
The unit automatically changed from diesel running to electric standby because it saw standby power connected and the auto switch option is on.· OtherOtherInfoCauses
- Standby power plugged in with auto switch enabled
- Normal changeover from diesel
- Electric ready input became active
Checks
- 1Confirm the standby power supply is correct in voltage and phase at the plug
- 2Check the auto switch setting in the configuration menu to see if it is enabled
- 3Check the unit runs normally on electric power once the switch has happened
- 4Clear the alarm and confirm it only repeats when you plug in
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 118Auto switch from electric to diesel
The unit automatically switched from electric standby to diesel, usually because standby power was lost or unplugged.· OtherOtherInfoCauses
- Standby power lost or unplugged
- Breaker tripped
- Auto switch enabled
Checks
- 1Check the standby supply and the breaker for a trip that cut power
- 2Check the plug and the power cord for damage or a loose connection
- 3Check the electric ready input signal is present when the plug is live
- 4Clear the alarm and confirm the unit stays on electric after a restart
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 122Diesel/electric circuit check
The circuit that selects between diesel and electric operation is faulty. The unit may not change over.· OtherOtherCheck soonCauses
- Contactor or relay failed
- Wiring damaged
Checks
- 1Check the changeover relay and wiring
- 2Watch the changeover signal on the display
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 141Auto switch diesel to electric disabled
The unit cannot automatically switch from diesel to electric power. It will stay on diesel when power is available.· OtherOtherCheck soonCauses
- Electric ready input fault
- Changeover circuit fault
Checks
- 1Check the electric ready input and wiring
- 2Check the changeover relay
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 148Auto switch electric to diesel disabled
The unit cannot automatically switch from electric to diesel power. If electric power is lost the unit may stop.· OtherOtherCheck soonCauses
- Diesel start circuit fault
- Changeover circuit fault
Checks
- 1Check the diesel start circuit
- 2Check the changeover relay
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 518Generator ground fault
The generator has a ground fault, a leak of current to the frame. The unit may stop for safety.· OtherOtherCheck soonCauses
- Generator winding or cable shorted to the frame
- Moisture in the generator
Checks
- 1Check the generator wiring and insulation
- 2Measure the insulation resistance
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 524Generator operational limit: voltage to frequency ratio
The ratio of the generator output voltage to its frequency is outside its limit, so the output is not within spec.· OtherOtherCheck soonCauses
- Generator regulator fault
- Engine speed wrong
Checks
- 1Check the engine speed and the generator output
- 2Check the regulator
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 525Generator frequency range fault
The generator output frequency is out of its range. Electric loads can be damaged.· Lost messageLost messageCheck soonCauses
- Engine speed wrong
- Generator or regulator fault
Checks
- 1Check the engine speed and the generator output frequency
- 2Check the regulator
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Thermo King 526Generator operational limit: output current
The output current of the generator is beyond its limit. The load is too high or there is a short.· Real conditionReal conditionCheck soonCauses
- Overloaded circuit
- Short in a load
Checks
- 1Check the electric loads and the wiring
- 2Measure the output current
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Thermo King 547AC bus phase loss
One phase of the AC supply is missing. The electric motor cannot run properly and may overheat.· Real conditionReal conditionCheck soonCauses
- Phase lost in the supply cable or plug
- Blown phase fuse
Checks
- 1Check each phase of the supply with a meter
- 2Check the plug and cable
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Shared checks
Checks, in order
- 1Check each supply phase with a meter at the plug
- 2Check the electric ready input on the display
- 3Check the generator wiring and insulation for damage
- 4Check the phase order if the motor runs backwards
- 5Check the changeover contactor and its wiring
- 6Check the electric loads and their connections
- 7Check the motor current against the nameplate
Causes
- Supply phase missing or reversed
- Electric ready input fault
- Winding or cable shorted to the frame
- Motor overloaded
Most common here: real condition (4 of 18)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: The unit does not run on electric power, with an alarm on the display.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.