Electric motor failed to run

What does Thermo King code 36 mean?

In electric standby the controller asked the electric motor to run but it did not start or stopped. It is the standby equivalent of the engine failed to start alarm. Urgency: stop now - shut down and fix before working on. Check first: confirm the supply voltage at the plug and breaker.

FaultStop36Thermo King · Electric standby (SR-2/SR-3/SR-4)

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Confirm the supply voltage at the plug and breaker

Then 3 more checks
Code shows hereFAULT36

Where this code shows

Press the alarm key or open the Alarms menu on the controller display to list active alarms.

Checks

0 of 4 done

Causes

  • Standby power cord or supply not live
  • Motor contactor not closing
  • Motor overload tripped
  • Phase loss at the supply

How it failed

You'll notice: Alarm 36; on standby the motor does not turn, or trips out, and the unit stays off until power is checked.

OtherRead from how the source describes the code

The source does not say how this one failed.

Meter test
Read the code with the service tool and note which other codes are active with it.
Good result
Codes that appear together usually share one cause - start with the wiring they share.

When to stop

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Electric standby motor, changeover and generator

Source

Thermo King Alarm Codes - North America (thermoking.com alarm code list)

This source lists 36 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.