EF Logo

Thermo King · Electric standby (SR-2/SR-3/SR-4)

Thermo King Fault Code 90

Electric overload

What does Thermo King code 90 mean?

The electric standby motor drew too much current and the overload tripped or the controller detected overload, shutting the motor down to protect it. Urgency: stop now - shut down and fix before working on. Check first: measure the supply voltage at the unit while it runs under full load in electric mode.

FaultStop90Thermo King · Electric standby (SR-2/SR-3/SR-4)

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Measure the supply voltage at the unit while it runs under full load in electric mode

Then 3 more checks
Code shows hereFAULT90

Where this code shows

Press the alarm key or open the Alarms menu on the controller display to list active alarms.

Checks

0 of 4 done

Causes

  • Low supply voltage causing high current
  • Blocked condenser or compressor seizure
  • Motor winding fault
  • Phase imbalance

How it failed

You'll notice: Alarm 90 and the unit stops in electric mode; it may restart after the overload cools.

Real conditionRead from how the source describes the code

The sensor reading is valid but outside the allowed range - the problem may be real.

allowed rangetime
The reading against the band the controller allows.
Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good result
If the gauge agrees with the display, fix the machine, not the sensor.

When to stop

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Electric standby motor, changeover and generator

Source

Thermo King Alarm Codes - North America (thermoking.com alarm code list)

This source lists 90 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.