Thermo King · Electric standby (SR-2/SR-3/SR-4)
Thermo King Fault Code 90
Electric overload
What does Thermo King code 90 mean?
The electric standby motor drew too much current and the overload tripped or the controller detected overload, shutting the motor down to protect it. Urgency: stop now - shut down and fix before working on. Check first: measure the supply voltage at the unit while it runs under full load in electric mode.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Measure the supply voltage at the unit while it runs under full load in electric mode
Then 3 more checksWhere this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
Checks
0 of 4 done
Causes
- Low supply voltage causing high current
- Blocked condenser or compressor seizure
- Motor winding fault
- Phase imbalance
How it failed
You'll notice: Alarm 90 and the unit stops in electric mode; it may restart after the overload cools.
Real conditionRead from how the source describes the code
The sensor reading is valid but outside the allowed range - the problem may be real.
- Meter test
- Check the real value with a separate gauge or thermometer before blaming the sensor.
- Good result
- If the gauge agrees with the display, fix the machine, not the sensor.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Electric standby motor, changeover and generator
3 other codes on this part are also real condition (OL, 526, 547). When they show together, start at the wiring and connector they share.
- tP4Power supply thermal protection alarmOtherStop now
- 36Electric motor failed to runOtherStop now
- 38Electric phase reversedOtherStop now
- 62Ammeter out of calibrationPart or controllerStop now
- 90Electric overloadReal conditionStop now
- 91Check electric ready inputOtherCheck soon
- 117Auto switch from diesel to electricOtherInformation
- 118Auto switch from electric to dieselOtherInformation
- 122Diesel/electric circuit checkOtherCheck soon
Show the other 9 codesHide the other codes
- OLElectric standby overloadReal conditionStop now
- tEPElectric standby motor thermal protection alarmOtherStop now
- 141Auto switch diesel to electric disabledOtherCheck soon
- 148Auto switch electric to diesel disabledOtherCheck soon
- 518Generator ground faultOtherCheck soon
- 524Generator operational limit: voltage to frequency ratioOtherCheck soon
- 525Generator frequency range faultLost messageCheck soon
- 526Generator operational limit: output currentReal conditionCheck soon
- 547AC bus phase lossReal conditionCheck soon
Source
Thermo King Alarm Codes - North America (thermoking.com alarm code list)
This source lists 90 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.