Thermo King · Pressure switches (SR-2/SR-3/SR-4)
Thermo King Fault Code 115
Check high pressure cutout switch
What does Thermo King code 115 mean?
The high pressure cutout switch is open when it should not be, or its circuit has a fault. This switch protects the system from excess discharge pressure. Urgency: stop now - shut down and fix before working on. Check first: check discharge pressure and the condenser for a real high pressure cause.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Check discharge pressure and the condenser for a real high pressure cause
Then 3 more checksWhere this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
Checks
0 of 4 done
Causes
- High pressure cutout switch tripped for real
- Switch failed open
- Wiring open
How it failed
You'll notice: Alarm 115; the compressor or unit will not run because the safety is open.
Real conditionRead from how the source describes the code
The sensor reading is valid but outside the allowed range - the problem may be real.
- Meter test
- Check the real value with a separate gauge or thermometer before blaming the sensor.
- Good result
- If the gauge agrees with the display, fix the machine, not the sensor.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Refrigeration pressures, scroll compressor limits, modulation and drive
4 other codes on this part are also real condition (PSE, 99, 116, 530). When they show together, start at the wiring and connector they share.
- 93Low compressor suction pressureOtherCheck soon
- 94Check loader 1 circuitOtherCheck soon
- 95Check loader 2 circuitOtherCheck soon
- 99High compressor pressure ratioReal conditionCheck soon
- 115Check high pressure cutout switchReal conditionStop now
- 116High pressure cut-in switch checkReal conditionInformation
- 154Low suction pressure switch failureOtherCheck soon
- 180TriPac compressor alarmOtherCheck soon
- 507Digital scroll output circuit check (scroll only)OtherInformation
Show the other 14 codesHide the other codes
- HPHigh discharge pressureShorted highStop now
- LPLow suction pressureOtherStop now
- PSEHigh pressure sensor faultReal conditionStop now
- 10High discharge pressure or temperatureShorted highStop now
- 34Check modulation circuitOtherCheck soon
- 48Check belts or clutchOtherCheck soon
- 86Check discharge pressure sensorOtherCheck soon
- 87Check suction pressure sensorOtherCheck soon
- 512High compressor suction pressure (scroll only)OtherCheck soon
- 513Low compressor suction ratio (scroll only)Lost messageCheck soon
- 514Low compressor discharge pressure (scroll only)OtherCheck soon
- 515Minimum ETV discharge superheat temperature (scroll)OtherCheck soon
- 530Low pressure differential (scroll only)Real conditionCheck soon
- 531Economizer pressure sensor check (scroll only)OtherCheck soon
Source
Thermo King Alarm Codes - North America (thermoking.com alarm code list)
This source lists 115 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.