This page covers the GP102 internal sensor faults, the HWFS and start-up self-test, the Skycoded display messages and the Deutz clutch signal engine code. The GP102 tests its own tilt sensor, analog channels, strain monitors and slave processor at start-up and while running.

More about these parts

HWFS is the hardware fail-safe check inside the module. Skycoded scissors show a three-digit number and text on the display in the hydraulic tray.

FaultCheck7-1Skyjack · GP102 internal faults, self-test, display and engine codes
Code shows hereFAULT7-1

Where this code shows

Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).

What do these codes mean?

Skyjack codes 7-1 to P1070 SPN 598 FMI 10 are all about the gP102 internal faults, self-test, display and engine codes. The most common failure type is lost message (3 of 12); none needs an immediate stop. Start with this check: check the module sits flat and the mounting bolts are tight, as the manual stresses.

How urgent are they?

None of the 12 codes here means stop now; 9 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Check soon9
  • Info3

What should I check first?

Check the module sits flat and the mounting bolts are tight, as the manual stresses

Shared checks

12 of 12

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Skyjack 7-1Bad tilt sensor

    The tilt sensor inside the GP102 module has failed its self-check.· Lost message
    Check soon

    Causes

    • GP102 mounted crooked or loose, which upsets the tilt sensor
    • Internal tilt sensor failure
    • Damaged module housing after a knock

    Checks

    1. 1Check the module is mounted flat and the mounting bolts are tight
    2. 2Check the machine is standing on level ground before reading the LED
    3. 3Cycle power and read the LED again to see if 7-1 returns
    4. 4Replace the module if the code returns with the module mounted correctly
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Skyjack 7-2Bad HWFS

    The module reports a fault in its HWFS circuit during self-test.· Part or controller
    Check soon

    Causes

    • Internal module fault
    • Low battery during start-up
    • Loose module connector

    Checks

    1. 1Check battery voltage at the module during start-up before suspecting it
    2. 2Cycle power and read the LED again to see if the code returns
    3. 3Check the module connectors are fully seated and not corroded
    4. 4Replace the module if the code returns with a healthy supply
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack 7-3Bad slave analogs

    The module's slave analogue inputs failed their self-check.· Other
    Check soon

    Causes

    • Internal analogue failure
    • Supply voltage problem
    • Loose module connector

    Checks

    1. 1Check the supply voltage at the module with the key on
    2. 2Check the module connectors are fully seated and the pins are clean
    3. 3Cycle power and read the LED again to see if the code returns
    4. 4Replace the module if the code returns with a healthy supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack 7-4Bad strain monitors

    The strain monitor circuit failed its self-check.· Erratic or implausible
    Check soon

    Causes

    • Internal module fault
    • Sensor wiring fault
    • Power supply dip at start-up

    Checks

    1. 1Check the supply to the module with the key on
    2. 2Check the P4 sensor wiring for damage or a loose connector
    3. 3Cycle power and read the LED again to see if the code returns
    4. 4Replace the module if the code returns with the sensors good
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Skyjack 7-5Bad slave micro

    The slave microprocessor inside the module has failed its check.· Part or controller
    Check soon

    Causes

    • Internal microprocessor failure on the slave side of the module
    • Supply dip at start-up corrupting the processor
    • Moisture or static damage to the board

    Checks

    1. 1Check the supply voltage at the module during start-up
    2. 2Cycle power and read the LED again to see if it returns
    3. 3Inspect the module for moisture or corrosion inside the housing
    4. 4Replace the module if the code returns with a healthy supply
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack 7-6HWFS stalled

    The HWFS circuit stopped responding while the module was already running, rather than failing at start-up.· Part or controller
    Check soon

    Causes

    • Supply dip or interruption while the machine is running
    • Module loose on its bracket so vibration upsets it
    • Moisture getting into the module after washing the machine
    • Internal fault in the module

    Checks

    1. 1Note exactly when it happens, for example during drive, lift or only when a pump starts
    2. 2Check battery voltage at the module while operating a heavy function
    3. 3Check the module mounting and connectors for looseness from vibration
    4. 4Look for water ingress in the module after pressure washing
    5. 5Replace the module if it keeps stalling with a healthy supply
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack 7-7Start-up

    The module is starting up.· Other
    Info

    Causes

    • Normal power-up sequence
    • Supply voltage unstable at start
    • Module resetting repeatedly

    Checks

    1. 1Wait a few seconds after power-on and read the LED again
    2. 2Check the supply voltage is steady while the module starts up
    3. 3Look for repeated resets, which show as the code returning every few seconds
    4. 4Replace the module if it never clears after the start-up period
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack 7-8Testing HWFS

    The module is running its HWFS test.· Other
    Info

    Causes

    • Normal start-up test
    • Test not completing because of a fault
    • Supply dip

    Checks

    1. 1Wait for the self-test to finish and read the LED again afterwards
    2. 2Check the supply voltage is steady during the test period
    3. 3Check the module connectors are seated and the pins are clean
    4. 4Replace the module if the test never completes
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack 111PINPAD (enter pinpad code)

    A Skycoded electric scissor shows 111 PINPAD when the optional key card or touchpad access is switched on, and no function will run.· Lost message
    Check soon

    Causes

    • Optional telematics or pinpad interlock setting reset to Lockable
    • Batteries replaced or flat so the setting reverted
    • Pinpad or card reader not in use on this machine

    Checks

    1. 1Open the hydraulic tray and wake the display and keypad
    2. 2Hold ESC until HELP: PRESS ENTER shows but do not press Enter
    3. 3Use the right arrow to reach Access Level 3, press Enter and enter the level 3 code 1-1-2-2 given in the Skyjack tech tip
    4. 4Go to Setups, Machine Defaults, Interlocks, Telematics and set it to Normal
    5. 5Escape back out, power off and on and confirm the display reads 112 EVERYTHING OK
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Skyjack 112EVERYTHING OK

    On a Skycoded scissor 112 is the normal ready screen.· Other
    Info

    Causes

    • No active fault - normal operation
    • A function inhibited by height, tilt or an interlock rather than a code
    • A control switch or emergency stop that is out of position

    Checks

    1. 1Nothing to repair; if a function does not work with 112 showing check the control switches and emergency stops
    2. 2Confirm the function you are testing is allowed at the current platform height
    3. 3Use the keypad menu to look at the inputs if only one function is dead
    4. 4Check the pothole bars and tilt state if drive is blocked
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack 137LOW BATTERY (shows when lift is attempted)

    A Skycoded scissor can show 137 LOW BATTERY only when lift up is tried, even though it drives and steers.· Lost message
    Check soon

    Causes

    • Master disconnect switch contacts loosened by constant bumping
    • Weak batteries or a loose battery connection
    • Cable fault in the battery tray or at the master switch
    • Loose connection at the main contactor or the Skycoded module

    Checks

    1. 1Go to the rear of the base by the steps and cycle the master disconnect on and off several times
    2. 2Retest lift up after cycling the switch to see if the code stays away
    3. 3Load test the batteries and check the connections and fuse
    4. 4Check the cables in the battery tray and behind the master switch
    5. 5Check the cable connections at the main contactor and Skycoded module, then charge fully and retest
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Skyjack P1070 SPN 598 FMI 10Deutz engine code: clutch signal abnormal rate of change

    Deutz engines with EMR5 software need to see a voltage change on one input every 48 hours, and if the ECU does not see it the code is set.· Erratic or implausible
    Check soon

    Causes

    • Relay in the base control panel not switching wire 233 (boom lifts)
    • Glow plug relay 11CR or its fuse and connector (TH telehandlers)
    • Wire 233 or wire 68 broken or loose

    Checks

    1. 1On boom lifts find wire 233 and check the relay that regulates it in the base control panel
    2. 2Check the relay connections and the wire for a voltage change when the engine runs
    3. 3On TH models inspect the 11CR glow plug relay, its fuse and connectors near the ECU and battery
    4. 4With Deutz Serdia software the circuit looked at is K19
    5. 5Contact Skyjack Technical Service if the code continues after testing
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

Shared checks

Checks, in order

  1. 1Check the module sits flat and the mounting bolts are tight, as the manual stresses
  2. 2Wait a few seconds and see whether the start-up code clears by itself
  3. 3Read the exact message on the display in the hydraulic tray
  4. 4Check battery voltage at the module during start-up
  5. 5Check battery voltage at the module during power-up
  6. 6For 111 reset the pinpad option in the setup menu
  7. 7Cycle power and read the LED again to see if it returns

Causes

  • Deutz EMR5 input not seeing its periodic voltage change
  • Module loose or crooked on its bracket
  • Low supply at start-up
  • Pinpad option reset after a battery change

Most common here: lost message (3 of 12)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: The machine may refuse to operate and the LED shows a 7-x pattern that returns after a restart.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.