Skyjack · GP102 module LED flash codes
Skyjack Fault Code 4‑1
P4-1 or P5-1 short to 0 V
What does Skyjack code 4-1 mean?
The module sees the sensor supply on plug P4 pin 1 or plug P5 pin 1 pulled to ground. Urgency: stop now - shut down and fix before working on. Check first: with the key off unplug P4 and see if the fault clears; the manual points at the wiring from P4-1 to the rest of the machine if it does.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
With the key off unplug P4 and see if the fault clears; the manual points at the wiring from P4-1 to the rest of the machine if it does
Then 4 more checksWhere this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
Checks
0 of 5 done
Causes
- Sensor supply wire on P4-1 or P5-1 chafed against the frame
- Cable pinched at the scissor pivot or under a cover
- Failed pressure or height transducer pulling its supply to ground
- Water in the P4 or P5 plug
How it failed
You'll notice: Lift and drive are blocked and the LED shows four flashes then one.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: P3, P4, P5 output shorts and supply voltage
- 4-1P4-1 or P5-1 short to 0 VOtherStop now
- 4-2P3-4 short to supplyShorted highStop now
- 4-3P3-4 short to 0 VOtherStop now
- 4-4P3-4 short to supply (second message)Shorted highStop now
- 4-5P3-6 short to 0 VShorted lowStop now
- 4-6P3-6 short to supplyShorted highStop now
- 5-1B+ supply too lowLost messageCheck soon
- 5-2Waiting for B+ on P2-12 / EMS inputs faultyOtherCheck soon
- 5-4Up/down select inputs active togetherOtherCheck soon
- 5-5Waiting for neutralOtherInformation
- 5-6Drive/lift inputs faultyOtherCheck soon
Other Skyjack codes: GP102 module LED flash codes
Source
This source lists 4-1 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Skyjack SJIII 3215 and 3219 DC electric scissors with the GP102 module (manual 155147AD, serials 10,000,574-10,000,630 and 22,019,597-22,022,792); later serial ranges can differ, check your own manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.