John Deere · Main controller (MCZ) - communication
John Deere CAN communication between main controller, engine controller and monitor fault codes
The main controller (MCZ), the engine controller, the data converter and the monitor controller talk over CAN. The MCZ codes say which messages it is missing: the engine controller sending speed, coolant temperature, fuel flow and air temperatures, or the monitor sending work mode and the security signal.
More about these partsLess
The monitor codes (DSZ) say the monitor cannot reach the main controller, the engine controller or itself.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes MCZ 11004.02 to DSZ 13007.02 are all about the cAN communication between main controller, engine controller and monitor. Most are lost message faults; 1 needs an immediate stop. Start with this check: read the prefix and which pair of controllers the code names, then check that the missing sender has power, ground and its fuse.
How urgent are they?
1 of 20 codes here means stop now; the other 19 can wait until the shift ends, but find the cause before the next one.
- Stop now1
- Check soon19
What should I check first?
Read the prefix and which pair of controllers the code names, then check that the missing sender has power, ground and its fuse
Shared checks20 of 20
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere MCZ 11004.02MCZ CAN communication error
The MCZ detected a fault on one of its CAN lines. Other controllers (engine, monitor) may stop reporting and the display may show alarms. This is a bus fault seen by the MCZ itself, so several controllers may drop out together. Several controllers dropping out at once is the typical sign of a bus fault. Measuring wire resistance with the battery off is the quick first test.· Lost messageLost messageCheck soonCauses
- Open or shorted CAN high or low wire in the main harness
- Missing or damaged CAN terminating resistor at one end of the bus
- Corroded or wet CAN connector pins
- A faulty controller pulling the CAN bus down
- CAN wires shorted together in a chafed harness section behind the cab
Checks
- 1Measure resistance across CAN high and low at a bus connector with the key off; about 60 ohms is normal for a bus with both terminators fitted
- 2Check each CAN wire for a short to ground and to supply
- 3Unplug controllers one at a time to see whether the bus recovers
- 4Inspect the CAN connectors at the MCZ, monitor and engine controller for moisture and corrosion
- 5Check the monitor for matching DSZ communication codes to find which controller is silent
- 6Check both CAN wires for shorts to each other or to ground, and the terminating resistors.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11005.02CAN communication error 2
The main controller reports a communication error on the second CAN circuit (CAN 2 in the list), so messages from other controllers on that circuit are not arriving. This is a fault on the second CAN circuit of the MCZ. The second circuit carries different controllers from the first.· Lost messageLost messageCheck soonCauses
- The unit that should send the main controller CAN bus is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Second CAN circuit wire broken inside a connector that was pulled apart for service
Checks
- 1Check the power, ground and fuse of the unit that sends the main controller CAN bus before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Measure the second CAN circuit wires separately from the first.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11006.02Engine controller communication error
The MCZ is not getting messages from the engine controller. Engine speed control from the dial may not work and the engine may stall or sit at one speed. The MCZ lost the engine controller entirely, so dial speed control may not work. Dial speed control and engine data both depend on this link. Engine start usually still works; only data and speed control are affected.· Lost messageLost messageStop nowCauses
- Open CAN wire between the MCZ and the engine controller
- Engine controller without power or ground
- Damaged engine controller connector
- CAN termination fault on the engine side of the bus
- Engine controller fuse blown or its ground strap loose on the engine
Checks
- 1Check the engine controller supply and ground at its connector with the key on
- 2Measure resistance between CAN high and CAN low at the engine controller plug with the key off
- 3Check the CAN wires between the engine controller and the MCZ for continuity and shorts
- 4Check for a matching DSZ 13002 on the monitor to confirm the engine controller link is down
- 5Inspect the engine controller plug for oil, water and bent pins
- 6Check the engine controller has power and ground; read its own codes.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11007.02(CAN 0) data converter communication error 1
The controller does not receive the expected data converter link, or it arrives too slowly or with invalid data, so that data cannot be used. The data converter link is missing, so converted data does not reach the MCZ. The data converter links the machine data to the monitor display. The converter changes data format between networks, so a dead converter hides many values at once.· Lost messageLost messageCheck soonCauses
- The unit that should send the data converter link is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Data converter lost power after a fuse or connector fault
Checks
- 1Check the power, ground and fuse of the unit that sends the data converter link before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check the data converter power, ground and CAN plug.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11008.02(CAN 1) data converter communication error 2
The controller does not receive the expected data converter link, or it arrives too slowly or with invalid data, so that data cannot be used. The data converter link is missing, so converted data does not reach the MCZ. The data converter links the machine data to the monitor display. The converter changes data format between networks, so a dead converter hides many values at once.· Lost messageLost messageCheck soonCauses
- The unit that should send the data converter link is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Data converter lost power after a fuse or connector fault
Checks
- 1Check the power, ground and fuse of the unit that sends the data converter link before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check the data converter power, ground and CAN plug.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11009.02(CAN 0) monitor controller communication error 1
The controller does not receive the expected monitor controller messages seen by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. Monitor messages on this CAN circuit are missing at the MCZ. Compare the CAN 0 and CAN 1 versions to see which circuit failed.· Lost messageLost messageCheck soonCauses
- The unit that should send the monitor controller messages seen by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Monitor restarting or without power at the moment the MCZ expected the message
Checks
- 1Check the power, ground and fuse of the unit that sends the monitor controller messages seen by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check the monitor power and the CAN circuit named in the code.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11010.02(CAN 1) monitor controller communication error 2
The controller does not receive the expected monitor controller messages seen by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. Monitor messages on this CAN circuit are missing at the MCZ. Compare the CAN 0 and CAN 1 versions to see which circuit failed.· Lost messageLost messageCheck soonCauses
- The unit that should send the monitor controller messages seen by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Monitor restarting or without power at the moment the MCZ expected the message
Checks
- 1Check the power, ground and fuse of the unit that sends the monitor controller messages seen by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check the monitor power and the CAN circuit named in the code.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11910.02Actual engine speed message error
The controller does not receive the expected engine data messages received by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. Only the actual engine speed message is missing. The engine runs normally; only the message to the MCZ is lost.· Lost messageLost messageCheck soonCauses
- The unit that should send the engine data messages received by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Engine speed message dropped while the engine controller was busy or in a fault mode
Checks
- 1Check the power, ground and fuse of the unit that sends the engine data messages received by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Compare engine speed on the monitor with the real engine speed.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11911.02Security signal received from monitor
The main controller received a security signal from the monitor, which means the machine security (anti-theft) condition may be active and engine or work functions can be locked. The security (anti-theft) signal from the monitor reached the MCZ, so the machine may be locked. This one is information about the security state, not a wiring fault. Re-entering the key or password usually clears it.· Lost messageLost messageCheck soonCauses
- Wiring or connector fault in the circuit behind this code
- The part or unit the code names failing
- Low or unstable supply voltage to the controller
- Machine security set by an incorrect key or password entry at the monitor
Checks
- 1Check the connector and wiring behind this code for corrosion, oil and pins that are pushed out
- 2Measure supply voltage and ground at the controller and clear the code to see if it returns
- 3Check that the security is released and the correct key or password is used.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11914.02Radiator coolant temperature message error
The controller does not receive the expected engine data messages received by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. Only the radiator coolant temperature message is missing. The engine runs normally; only the radiator coolant reading is lost.· Lost messageLost messageCheck soonCauses
- The unit that should send the engine data messages received by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Coolant temperature message dropped because the engine coolant sensor itself is faulty
Checks
- 1Check the power, ground and fuse of the unit that sends the engine data messages received by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Compare the monitor coolant temperature with a gauge reading.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11918.02Work mode received message error
The controller does not receive the expected monitor controller messages seen by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. The work mode message from the monitor is missing, so mode selection may not take effect. Only the work mode selection is lost, other monitor data may still arrive.· Lost messageLost messageCheck soonCauses
- The unit that should send the monitor controller messages seen by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Work mode message lost during a monitor restart
Checks
- 1Check the power, ground and fuse of the unit that sends the monitor controller messages seen by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Change work mode on the monitor and watch whether the MCZ follows.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11920.02Fuel flow rate message error
The controller does not receive the expected engine data messages received by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. Only the fuel flow rate message is missing. The engine runs normally; only the fuel use figure is lost.· Lost messageLost messageCheck soonCauses
- The unit that should send the engine data messages received by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Fuel flow message not sent on engines that do not support it
Checks
- 1Check the power, ground and fuse of the unit that sends the engine data messages received by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check whether the fuel use figure on the monitor updates.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11983.02Intake air temperature receive error
The controller does not receive the expected engine data messages received by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. Only the intake air temperature message is missing. The engine runs normally; only the intake air reading is lost.· OtherOtherCheck soonCauses
- The unit that should send the engine data messages received by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Intake air message dropped when its sensor failed at the engine controller
Checks
- 1Check the power, ground and fuse of the unit that sends the engine data messages received by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Compare the displayed intake air temperature with ambient.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11984.02Boost temperature receive error
The controller does not receive the expected engine data messages received by the main controller, or it arrives too slowly or with invalid data, so that data cannot be used. Only the boost temperature message is missing. The engine runs normally; only the boost air reading is lost.· OtherOtherCheck soonCauses
- The unit that should send the engine data messages received by the main controller is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Boost message dropped when its sensor failed at the engine controller
Checks
- 1Check the power, ground and fuse of the unit that sends the engine data messages received by the main controller before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Compare the displayed boost temperature with the intake air reading.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere DSZ 13002.02Monitor: engine controller communication error
The monitor stopped receiving messages from another controller. Check CAN 0 between the monitor and the engine controller. The MCZ lost the engine controller entirely, so dial speed control may not work. Dial speed control and engine data both depend on this link. Engine start usually still works; only data and speed control are affected.· Lost messageLost messageCheck soonCauses
- Open or damaged CAN 0 wire between the monitor and the engine controller
- Engine controller without power or ground
- Damaged engine controller connector
- Engine controller fuse blown or its ground strap loose on the engine
Checks
- 1Check the engine controller supply and ground at its connector with the key on
- 2Check CAN 0 wire continuity between the monitor and the engine controller
- 3Measure CAN high to low resistance with the key off to confirm the terminators
- 4Check the engine controller has power and ground; read its own codes.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere DSZ 13003.02Monitor: main controller communication error 1
The monitor stopped receiving messages from another controller. Check CAN 0 between the monitor and the MCZ. The monitor lost the main controller on CAN 0. The monitor keeps showing its own screens when this link fails. Mode and settings changes on the monitor stop reaching the machine.· Lost messageLost messageCheck soonCauses
- Open or damaged CAN 0 wire between the monitor and the MCZ
- MCZ without power or ground, so it is not transmitting
- Connector fault at the monitor or the MCZ
- CAN 0 connector at the MCZ not fully latched
Checks
- 1Check the MCZ power and ground pins at its plug with the key on
- 2Check CAN 0 wire continuity between the monitor and the MCZ plugs
- 3Measure CAN high to low resistance on CAN 0 with the key off
- 4Check the CAN 0 wiring between monitor and MCZ and the MCZ power.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere DSZ 13004.02Main controller (MCZ) communication error 2
The controller does not receive the expected monitor to main controller link, or it arrives too slowly or with invalid data, so that data cannot be used. The monitor to main controller link is missing on the second circuit. This is the second link between monitor and MCZ, so the first link may still work.· Lost messageLost messageCheck soonCauses
- The unit that should send the monitor to main controller link is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Second monitor to MCZ circuit open at a connector
Checks
- 1Check the power, ground and fuse of the unit that sends the monitor to main controller link before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check the second circuit wiring between the monitor and the MCZ.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere DSZ 13005.02Monitor controller (DSZ) communication error 1
The controller does not receive the expected monitor controller CAN links, or it arrives too slowly or with invalid data, so that data cannot be used. The monitor controller own CAN link is not received, so it cannot hear itself or its partner. Two numbers exist for the two CAN circuits of the monitor.· Lost messageLost messageCheck soonCauses
- The unit that should send the monitor controller CAN links is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Monitor connector pins backed out so its own CAN line is open
Checks
- 1Check the power, ground and fuse of the unit that sends the monitor controller CAN links before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check the monitor connector and CAN wiring on the circuit named.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere DSZ 13006.02Monitor controller (DSZ) communication error 2
The controller does not receive the expected monitor controller CAN links, or it arrives too slowly or with invalid data, so that data cannot be used. The monitor controller own CAN link is not received, so it cannot hear itself or its partner. Two numbers exist for the two CAN circuits of the monitor.· Lost messageLost messageCheck soonCauses
- The unit that should send the monitor controller CAN links is off, damaged or missing its power
- Broken, shorted or corroded CAN wire or connector between the units
- Missing or faulty CAN termination on the bus
- Monitor connector pins backed out so its own CAN line is open
Checks
- 1Check the power, ground and fuse of the unit that sends the monitor controller CAN links before the CAN wiring
- 2Inspect the CAN connectors for corrosion and measure the CAN wire continuity and termination as the wiring manual describes
- 3Check the monitor connector and CAN wiring on the circuit named.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere DSZ 13007.02Monitor: machine controller (BCZ) communication error
The monitor stopped receiving messages from the machine controller (BCZ) on CAN 1. Check the CAN 1 wiring and the BCZ supply first. The monitor lost the machine controller (BCZ) on CAN 1. The BCZ is the machine controller on CAN 1, not the engine or main controller.· Lost messageLost messageCheck soonCauses
- Open or shorted CAN 1 wire between the monitor and the BCZ
- BCZ without power or ground
- Connector fault at the BCZ
- CAN 1 branch to the machine controller broken or the BCZ not powered
Checks
- 1Check the BCZ supply and ground at its connector with the key on
- 2Check CAN 1 wire continuity between the monitor and the BCZ and look for a short to ground
- 3Measure CAN 1 high to low resistance with the key off
- 4Check the CAN 1 wiring and the BCZ power and ground.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Read the prefix and which pair of controllers the code names, then check that the missing sender has power, ground and its fuse
- 2Read the sender own codes first: a controller with its own fault or no power explains every message code from it
- 3With the battery off measure the resistance between the two CAN wires; the manual gives the expected value
- 4Inspect CAN connectors at both controllers for corrosion and pushed-out pins
- 5For the security signal code confirm the machine security is released and the key or password is the stored one
Causes
- CAN wire broken, shorted or corroded at a connector between two controllers
- One controller without power, ground or fuse, or restarting
- Missing or faulty CAN termination resistor on the bus
- Software or security data mismatch after a controller was replaced
Most codes here: lost message (18 of 20)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Engine data on the monitor is missing or stuck, mode selections may be ignored and engine based controls may fall back to defaults.
Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.