John Deere · Main controller (MCZ) - pressure sensors
John Deere Fault Code MCZ 11302.04
Boom up pressure sensor (B30) signal low
What does John Deere code MCZ 11302.04 mean?
The main controller reads the boom up pressure sensor (B30) on the boom raise circuit as low. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky. Urgency: check soon - the machine may derate or limit a function. Check first: check supply and ground voltage at the unplugged B30 connector with the key on.
- MCZ
- Which controller reports it
- 11302
- What is at fault
- .04
- How it failed
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Check supply and ground voltage at the unplugged B30 connector with the key on
Then 5 more checksWhere this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
Checks
0 of 6 done
Causes
- B30 signal wire open from chafing along the boom
- B30 signal wire shorted to the machine frame
- No 5 V at B30 because of a damaged supply wire
- B30 failed low
How it failed
You'll notice: Boom up pressure reads zero, so the MCZ has no feedback on boom raise load.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Boom, arm and bucket pressure sensors
- MCZ 11302.03Boom up pressure sensor (B30) signal highOtherCheck soon
- MCZ 11302.04Boom up pressure sensor (B30) signal lowOtherCheck soon
- MCZ 11303.03Arm in pressure sensor (B31) signal highOtherCheck soon
- MCZ 11303.04Arm in pressure sensor (B31) signal lowOtherCheck soon
- MCZ 11325.03Bucket curl pressure sensor circuit highOtherCheck soon
- MCZ 11325.04Bucket curl pressure sensor circuit lowOtherCheck soon
- MCZ 11802.03Boom bottom pressure sensor circuit voltage highShorted highCheck soon
- MCZ 11802.04Boom bottom pressure sensor circuit voltage lowShorted lowCheck soon
- MCZ 11995.03Arm out pressure sensor circuit highLost messageCheck soon
Show the other 5 codesHide the other codes
- MCZ 11995.04Arm out pressure sensor circuit lowLost messageCheck soon
- MCZ 11997.03Bucket dump pressure sensor circuit highLost messageCheck soon
- MCZ 11997.04Bucket dump pressure sensor circuit lowLost messageCheck soon
- MCZ 11998.03Boom down pressure sensor circuit highLost messageCheck soon
- MCZ 11998.04Boom down pressure sensor circuit lowLost messageCheck soon
Other John Deere codes: Main controller (MCZ) - pressure sensors
Related on Equipments Finder
Source
Excavator Fault Codes - John Deere excavators fault codes list (MCZ/ECU/DSZ)
This source lists MCZ 11302.04 and its meaning. The guidance on this page is general, not taken from it.
The source covers: John Deere G-series excavators (210G/210GLC and 350G class) with MCZ main controller; confirm against serial number.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.