EF Logo

John Deere · Main controller (MCZ) - communication

John Deere Fault Code MCZ 11004.02

MCZ CAN communication error

What does John Deere code MCZ 11004.02 mean?

The MCZ detected a fault on one of its CAN lines. Other controllers (engine, monitor) may stop reporting and the display may show alarms. Urgency: check soon - the machine may derate or limit a function. Check first: measure resistance across CAN high and low at a bus connector with the key off; about 60 ohms is normal for a bus with both terminators fitted.

FaultCheckMCZ11004.02John Deere · Main controller (MCZ) - communication
MCZ
Which controller reports it
11004
What is at fault
.02
How it failed

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Measure resistance across CAN high and low at a bus connector with the key off; about 60 ohms is normal for a bus with both terminators fitted

Then 5 more checks
Code shows hereFAULTMCZ11004.02

Where this code shows

Turn the key on and open the monitor's diagnostic/fault screen.

Checks

0 of 6 done

Causes

  • Open or shorted CAN high or low wire in the main harness
  • Missing or damaged CAN terminating resistor at one end of the bus
  • Corroded or wet CAN connector pins
  • A faulty controller pulling the CAN bus down
1 more cause
  • CAN wires shorted together in a chafed harness section behind the cab

How it failed

You'll notice: A fault on the CAN data line stops the MCZ talking to the engine controller and the monitor.

Lost messageRead from how the source describes the code

A module stopped hearing another on the data link, or the data came late or garbled.

Module AModule BCAN HCAN L120 Ω120 Ω
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.
Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good result
About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

When to stop

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: CAN communication between main controller, engine controller and monitor

17 other codes on this part are also lost message (MCZ 11005.02, MCZ 11006.02, MCZ 11007.02, MCZ 11008.02 and more). When they show together, start at the wiring and connector they share.

Show the other 11 codes
All 20 CAN communication between main controller, engine controller and monitor codes on one page

Source

Excavator Fault Codes - John Deere excavators fault codes list (MCZ/ECU/DSZ)

This source lists MCZ 11004.02 and its meaning. The guidance on this page is general, not taken from it.

The source covers: John Deere G-series excavators (210G/210GLC and 350G class) with MCZ main controller; confirm against serial number.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.