John Deere · Main controller (MCZ) - alarms
John Deere Hydraulic, pilot and machine alarms fault codes
These alarms report a machine state rather than a failed wire: pilot shut-off lever position, crane function, electric lever system, hydraulic line or return filter restriction, hydraulic oil temperature and cooling, hydraulic fan low rotation, the idle stop relay circuit and a general system error. The monitor or MCZ raises them when an input leaves its normal state.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes MCZ 11459.02 to MCZ 20303.02 are all about the hydraulic, pilot and machine alarms. The most common failure type is shorted high (2 of 14); 1 needs an immediate stop. Start with this check: confirm the real condition at the machine first: lever position, filter service state, oil temperature on the monitor.
How urgent are they?
1 of 14 codes here means stop now; the other 13 can wait until the shift ends, but find the cause before the next one.
- Stop now1
- Check soon13
What should I check first?
Confirm the real condition at the machine first: lever position, filter service state, oil temperature on the monitor
Shared checks14 of 14
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere MCZ 11459.02Idle stop relay circuit malfunction
The MCZ sees a fault in the auto idle stop relay circuit. The auto idle shutdown timer may not work, or the engine may shut off unexpectedly at idle, and the operator may see a warning on the monitor.· OtherOtherCheck soonCauses
- Idle stop relay failed or sticking
- Open or shorted wire in the relay circuit
- Blown relay fuse
- Loose or corroded relay socket
Checks
- 1Check the idle stop relay fuse and the supply to the relay
- 2Swap the relay with a similar one from the fuse box and test the function
- 3Check the relay coil circuit wiring for continuity and shorts
- 4Check the relay socket terminals for corrosion and spread contacts
- 5Run the machine at idle after the repair and confirm the auto idle timer and shutdown work as set
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 20009.02Hydraulic oil cooling system abnormal
The MCZ judges that the hydraulic oil cooling system is not removing heat, or that the fan circuit is not doing what is commanded. The operator may see rising oil temperature and the machine can slow down to protect the system.· Lost messageLost messageCheck soonCauses
- Oil cooler fins packed with dust, chaff or mud so air cannot pass through
- Hydraulic fan running slow or not at all because of a fan drive, solenoid or speed sensor fault
- Low hydraulic oil level or the wrong oil, so the oil heats faster than it cools
- An oil temperature sensor reading wrongly and tripping the cooling check
Checks
- 1Look at the oil cooler and radiator core from both sides and wash out any packed debris
- 2Watch the fan at full engine speed and compare its speed with the value shown on the monitor
- 3Check the hydraulic oil level and condition on the sight gauge with the machine parked level
- 4Compare the B40 and B68 oil temperature readings on the monitor with an infrared reading taken at the tank
- 5Look for fan solenoid or fan speed codes logged with this one before replacing any parts
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 20011.02Electric lever alarm
The control lever system reports an abnormal condition. The operator may find one or more machine functions disabled or erratic, and other lever or pressure sensor codes are normally logged alongside it.· Erratic or implausibleErratic or implausibleCheck soonCauses
- A lever position sensor out of range or failing
- Lever supply, ground or signal wiring damaged
- Wet or corroded lever connector
Checks
- 1Read the lever channels on the monitor service screen and see which lever shows a bad value at rest
- 2Check the code list for lever or pressure sensor codes logged alongside this alarm
- 3Measure the lever supply and ground at its plug with the key on
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
John Deere MCZ 20012.02Line filter restriction alarm
The hydraulic line filter restriction switch is active, so oil is not passing the filter easily. Return flow is limited and the machine may feel slow, particularly when the oil is cold or after long service intervals.· Real conditionReal conditionCheck soonCauses
- Line filter element clogged with contamination or past its change interval
- Cold oil thickening and tripping the switch temporarily
- Filter restriction switch faulty or its wiring grounded
- Wrong or poor quality filter element fitted
Checks
- 1Compare the service hours with the line filter change interval
- 2Warm the oil up and see whether the alarm clears; an alarm only when cold is usually oil thickness
- 3Unplug the switch and check that the alarm clears and the switch opens with the plug off
- 4Cut open the old filter or inspect the drained oil for metal and debris
- 5Fit a new filter element of the correct grade and recheck
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 20013.02Hydraulic fan low rotation warning
Hydraulic fan speed is below the commanded value, so cooling of the engine and oil is reduced. The operator may see temperatures climb under load and the fan may be audibly slow.· OtherOtherCheck soonCauses
- Fan drive motor or pump worn or restricted
- Fan speed command solenoid or its wiring faulty
- Fan speed sensor reading wrongly
- Low hydraulic oil or a blocked fan circuit filter
Checks
- 1Watch the fan at full engine speed and compare it with the commanded speed shown on the monitor
- 2Check for other fan solenoid or fan speed sensor codes logged at the same time
- 3Check the fan circuit pressure and flow with the dealer tool or a gauge
- 4Inspect the fan drive hoses for kinks, leaks and soft spots
- 5Check the hydraulic oil level and condition before condemning the fan motor
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 20062.02Hydraulic oil temperature alarm
The hydraulic oil temperature is above the alarm limit. Continued work can damage seals, hoses and pumps, and the operator may see the temperature gauge in the red and reduced hydraulic performance.· Lost messageLost messageStop nowCauses
- Oil cooler blocked or the fan not turning fast enough
- Hydraulic oil level low or the wrong oil in the system
- A relief valve or pump leaking internally and turning hydraulic power into heat
- Oil temperature sensor reading wrongly
Checks
- 1Stop work and let the machine idle to cool, then check the cooler and radiator for debris
- 2Check the hydraulic oil level and look around the pumps and valves for leaks
- 3Compare the B40 reading with an infrared measurement taken on the tank
- 4Check the fan operation and any fan or temperature codes in the list
- 5Look at how the machine is being used; long work against a relief setting makes heat fast
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere DSZ 20105.02Hydraulic oil filter restriction alarm
The hydraulic oil filter restriction switch is active, meaning pressure drop across the filter is above the limit. The operator may find the machine slow, and the filter should be changed soon.· Shorted highShorted highCheck soonCauses
- Hydraulic filter element blocked
- Cold oil giving a false restriction signal
- Restriction switch faulty
Checks
- 1Check the filter service interval against the machine hours
- 2Warm the oil and see whether the alarm clears
- 3Unplug the switch and check whether the alarm clears
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere ICZ 20105.02Hydraulic oil filter restriction alarm
The information controller (ICZ) list carries the same code as the monitor (DSZ) list. The hydraulic oil filter restriction switch is active, meaning pressure drop across the filter is above the limit. The operator may find the machine slow, and the filter should be changed soon.· Shorted highShorted highCheck soonCauses
- Hydraulic filter element blocked
- Cold oil giving a false restriction signal
- Restriction switch faulty
Checks
- 1Check the filter service interval against the machine hours
- 2Warm the oil and see whether the alarm clears
- 3Unplug the switch and check whether the alarm clears
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere DSZ 20109.02Pilot control shut-off lever alarm
The pilot control shut-off (lock) lever signal is active or faulty, so the monitor sees the lever in an unexpected position. Hydraulic functions may stay locked out or the machine may not start.· OtherOtherCheck soonCauses
- Lock lever switch out of adjustment
- Switch wiring open or shorted
- Switch failed
Checks
- 1Move the lever and watch the switch state on the monitor
- 2Check the switch with a meter in both lever positions
- 3Inspect the lock lever switch wiring for chafing and cuts along its run to the monitor
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ICZ 20109.02Pilot control shut-off lever alarm
The information controller (ICZ) list carries the same code as the monitor (DSZ) list. The pilot control shut-off (lock) lever signal is active or faulty, so the monitor sees the lever in an unexpected position. Hydraulic functions may stay locked out or the machine may not start.· OtherOtherCheck soonCauses
- Lock lever switch out of adjustment
- Switch wiring open or shorted
- Switch failed
Checks
- 1Move the lever and watch the switch state on the monitor
- 2Check the switch with a meter in both lever positions
- 3Inspect the lock lever switch wiring for chafing and cuts along its run to the monitor
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere DSZ 20113.02System error alarm
The monitor shows a general system error alarm. The code does not name a single part; it is raised when one of the controllers reports a fault that the monitor has no more specific alarm for, so the other codes hold the real cause.· OtherOtherCheck soonCauses
- Another controller has a stored fault that triggered this general alarm
- Communication between the monitor and a controller interrupted
- Low supply voltage making a controller restart
- A monitor software or configuration problem
Checks
- 1Read the code lists of the main controller, engine controller and monitor first, since the alarm points to a fault stored elsewhere
- 2Check battery voltage and the ground straps, because low voltage can set odd alarms
- 3Check the CAN connectors between the monitor and the controllers for corrosion and loose pins
- 4Clear the alarm and run the machine to see which code returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere DSZ 20133.02Crane function alarm
The monitor shows the crane function alarm. It is raised on machines set up for lifting work when the crane (lifting) function reports a problem or is used outside its allowed conditions, so the lifting limits may not be applied.· OtherOtherCheck soonCauses
- Lifting mode switch or overload sensor circuit faulty
- Crane function option wired or configured wrongly
- Pressure sensor or relief solenoid for lifting reporting a fault
Checks
- 1Check whether the machine is fitted and configured for crane work before looking for a hardware fault
- 2Read the main controller codes for lifting related sensors and solenoids, such as the boom overload relief solenoid
- 3Inspect the lifting mode switch plug and harness for corrosion and chafe
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ICZ 20133.02Crane function alarm
The information controller (ICZ) list carries the same code as the monitor (DSZ) list. The monitor shows the crane function alarm. It is raised on machines set up for lifting work when the crane (lifting) function reports a problem or is used outside its allowed conditions, so the lifting limits may not be applied.· OtherOtherCheck soonCauses
- Lifting mode switch or overload sensor circuit faulty
- Crane function option wired or configured wrongly
- Pressure sensor or relief solenoid for lifting reporting a fault
Checks
- 1Check whether the machine is fitted and configured for crane work before looking for a hardware fault
- 2Read the main controller codes for lifting related sensors and solenoids, such as the boom overload relief solenoid
- 3Inspect the lifting mode switch plug and harness for corrosion and chafe
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 20303.02Electric lever pilot cut alarm
The MCZ saw an abnormal signal on an electric lever while it should be in neutral, and the pilot cut was triggered. The operator may find a function locked out until the condition clears.· OtherOtherCheck soonCauses
- Electric lever off neutral from a mechanical or sensor fault
- Lever signal wire shorted or open
- Lever supply voltage out of range
Checks
- 1Check which lever the monitor shows as off neutral
- 2Check that the lever centres freely and its boot is not binding
- 3Measure the lever supply and signal voltages at its plug
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Confirm the real condition at the machine first: lever position, filter service state, oil temperature on the monitor
- 2Check the oil cooler and hydraulic fan for dirt and correct rotation for temperature and fan alarms
- 3Replace a restricted hydraulic filter and re-test before suspecting the switch
- 4Check the switch or sensor plug and wiring for the alarm named, with both ends unplugged
- 5Clear the alarm after the repair and run the machine to see if it returns
Causes
- The real condition is present: hot oil, a blocked filter or the lever in the wrong position
- Switch or sensor behind the alarm failing or wired wrongly
- Wire broken or shorted between the input and the controller
- Cooler or fan not keeping the hydraulic oil cool
Most common here: shorted high (2 of 14)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: An alarm appears on the monitor and the related function may be restricted; hydraulic oil temperature and filter alarms should be acted on before the machine is worked hard.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
