John Deere Attachment relief and 2-spool valve unit solenoids fault codes

Proportional solenoids set the relief pressures of the attachment circuit: relief 1 the upper limit, relief 2 the lower, and the breaker relief solenoid the limit for a hydraulic hammer. The boom overload relief solenoid limits boom pressure under load.

More about these parts

The SJ and SZ solenoids sit in two 2-spool valve units that route oil to optional functions. The MCZ compares drive current and fed-back current and sets a code when they differ.

FaultCheckMCZ 11408.02John Deere · Attachment relief and 2-spool valve unit solenoids
Code shows hereFAULTMCZ 11408.02

Where this code shows

Turn the key on and open the monitor's diagnostic/fault screen.

What do these codes mean?

John Deere codes MCZ 11408.02 to MCZ 11989.04 are all about the attachment relief and 2-spool valve unit solenoids. Most are real condition faults; none needs an immediate stop. Start with this check: check which valve the code names (relief 1, relief 2, breaker relief, boom overload, SJ or SZ) and unplug only that one.

How urgent are they?

None of the 18 codes here means stop now; all 18 can wait until the shift ends, but find the cause before the next one.

  • Check soon18

What should I check first?

Check which valve the code names (relief 1, relief 2, breaker relief, boom overload, SJ or SZ) and unplug only that one

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • John Deere MCZ 11408.022-Spool solenoid valve unit (SJ) abnormal feedback

    The current feedback of the 2-spool solenoid valve unit (SJ) is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the 2-spool solenoid valve unit (SJ)
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly
    • Coil of the SJ solenoid burnt after the unit ran hot while the optional function was held on for a long time

    Checks

    1. 1Measure the 2-spool solenoid valve unit (SJ) coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    3. 3Swap nothing yet: note which optional function stops working, since that points at the SJ unit and not the SZ unit.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11408.032-Spool solenoid valve unit (SJ) feedback high input

    The feedback current of the 2-spool solenoid valve unit (SJ) is too high, so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the 2-spool solenoid valve unit (SJ) coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on
    • Coil of the SJ solenoid burnt after the unit ran hot while the optional function was held on for a long time

    Checks

    1. 1Measure the 2-spool solenoid valve unit (SJ) coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    3. 3Swap nothing yet: note which optional function stops working, since that points at the SJ unit and not the SZ unit.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11408.042-Spool solenoid valve unit (SJ) feedback low input

    The feedback current of the 2-spool solenoid valve unit (SJ) is too low, so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the 2-spool solenoid valve unit (SJ)
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving
    • Coil of the SJ solenoid burnt after the unit ran hot while the optional function was held on for a long time

    Checks

    1. 1Measure the 2-spool solenoid valve unit (SJ) coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    3. 3Swap nothing yet: note which optional function stops working, since that points at the SJ unit and not the SZ unit.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11409.022-Spool solenoid valve unit (SZ) abnormal feedback

    The current feedback of the 2-spool solenoid valve unit (SZ) is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the 2-spool solenoid valve unit (SZ)
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly
    • Plug of the SZ unit carrying oil or water from a weeping hose above it, shorting two pins

    Checks

    1. 1Measure the 2-spool solenoid valve unit (SZ) coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    3. 3Note which optional function stops working; if it is the second one the SZ unit is the one to test.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11409.032-Spool solenoid valve unit (SZ) feedback high input

    The feedback current of the 2-spool solenoid valve unit (SZ) is too high, so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the 2-spool solenoid valve unit (SZ) coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on
    • Plug of the SZ unit carrying oil or water from a weeping hose above it, shorting two pins

    Checks

    1. 1Measure the 2-spool solenoid valve unit (SZ) coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    3. 3Note which optional function stops working; if it is the second one the SZ unit is the one to test.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11409.042-Spool solenoid valve unit (SZ) feedback low input

    The feedback current of the 2-spool solenoid valve unit (SZ) is too low, so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the 2-spool solenoid valve unit (SZ)
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving
    • Plug of the SZ unit carrying oil or water from a weeping hose above it, shorting two pins

    Checks

    1. 1Measure the 2-spool solenoid valve unit (SZ) coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    3. 3Note which optional function stops working; if it is the second one the SZ unit is the one to test.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11434.02Attachment relief 1 (upper) proportional solenoid valve abnormal feedback

    The current feedback of the attachment relief 1 (upper) proportional solenoid valve is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the attachment relief 1 (upper) proportional solenoid valve
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly
    • Relief 1 proportional coil overheated by a tool run for a long period at the upper pressure setting

    Checks

    1. 1Measure the attachment relief 1 (upper) proportional solenoid valve coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    3. 3Run the tool and watch the commanded relief current for relief 1 on the service screen.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11434.03Attachment relief 1 (upper) proportional solenoid valve feedback high current

    The feedback current of the attachment relief 1 (upper) proportional solenoid valve is too high, so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the attachment relief 1 (upper) proportional solenoid valve coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on
    • Relief 1 proportional coil overheated by a tool run for a long period at the upper pressure setting

    Checks

    1. 1Measure the attachment relief 1 (upper) proportional solenoid valve coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    3. 3Run the tool and watch the commanded relief current for relief 1 on the service screen.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11434.04Attachment relief 1 (upper) proportional solenoid valve feedback low current

    The feedback current of the attachment relief 1 (upper) proportional solenoid valve is too low, so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the attachment relief 1 (upper) proportional solenoid valve
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving
    • Relief 1 proportional coil overheated by a tool run for a long period at the upper pressure setting

    Checks

    1. 1Measure the attachment relief 1 (upper) proportional solenoid valve coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    3. 3Run the tool and watch the commanded relief current for relief 1 on the service screen.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11435.02Attachment relief 2 (lower) proportional solenoid valve abnormal feedback

    The current feedback of the attachment relief 2 (lower) proportional solenoid valve is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the attachment relief 2 (lower) proportional solenoid valve
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly
    • Relief 2 wire chafed on the boom where it runs beside the tool hoses

    Checks

    1. 1Measure the attachment relief 2 (lower) proportional solenoid valve coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    3. 3Compare the relief 2 commanded current with relief 1 while the tool runs; both should be driven.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11435.03Attachment relief 2 (lower) proportional solenoid valve feedback high current

    The feedback current of the attachment relief 2 (lower) proportional solenoid valve is too high, so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the attachment relief 2 (lower) proportional solenoid valve coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on
    • Relief 2 wire chafed on the boom where it runs beside the tool hoses

    Checks

    1. 1Measure the attachment relief 2 (lower) proportional solenoid valve coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    3. 3Compare the relief 2 commanded current with relief 1 while the tool runs; both should be driven.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11435.04Attachment relief 2 (lower) proportional solenoid valve feedback low current

    The feedback current of the attachment relief 2 (lower) proportional solenoid valve is too low, so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the attachment relief 2 (lower) proportional solenoid valve
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving
    • Relief 2 wire chafed on the boom where it runs beside the tool hoses

    Checks

    1. 1Measure the attachment relief 2 (lower) proportional solenoid valve coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    3. 3Compare the relief 2 commanded current with relief 1 while the tool runs; both should be driven.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11436.02Breaker relief proportional solenoid valve abnormal feedback

    The current feedback of the breaker relief proportional solenoid valve is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the breaker relief proportional solenoid valve
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly
    • Breaker relief coil damaged by the vibration of a hydraulic hammer shaking the plug loose

    Checks

    1. 1Measure the breaker relief proportional solenoid valve coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    3. 3Select breaker mode and check the breaker relief current rises on the service screen.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11436.03Breaker relief proportional solenoid valve feedback high current

    The feedback current of the breaker relief proportional solenoid valve is too high, so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the breaker relief proportional solenoid valve coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on
    • Breaker relief coil damaged by the vibration of a hydraulic hammer shaking the plug loose

    Checks

    1. 1Measure the breaker relief proportional solenoid valve coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    3. 3Select breaker mode and check the breaker relief current rises on the service screen.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11436.04Breaker relief proportional solenoid valve feedback low current

    The feedback current of the breaker relief proportional solenoid valve is too low, so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the breaker relief proportional solenoid valve
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving
    • Breaker relief coil damaged by the vibration of a hydraulic hammer shaking the plug loose

    Checks

    1. 1Measure the breaker relief proportional solenoid valve coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    3. 3Select breaker mode and check the breaker relief current rises on the service screen.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11989.02Boom overload relief solenoid feedback current abnormal

    The current feedback of the boom overload relief solenoid is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· Real condition
    Check soon

    Causes

    • Faulty coil or damaged wiring at the boom overload relief solenoid
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly
    • Boom overload relief wire rubbed through near the boom foot, where the harness flexes with every lift

    Checks

    1. 1Measure the boom overload relief solenoid coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    3. 3Check the boom overload relief current on the service screen while raising a load; it should rise with load.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11989.03Boom overload relief solenoid feedback current high

    The feedback current of the boom overload relief solenoid is too high, so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the boom overload relief solenoid coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on
    • Boom overload relief wire rubbed through near the boom foot, where the harness flexes with every lift

    Checks

    1. 1Measure the boom overload relief solenoid coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    3. 3Check the boom overload relief current on the service screen while raising a load; it should rise with load.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11989.04Boom overload relief solenoid feedback current low

    The feedback current of the boom overload relief solenoid is too low, so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the boom overload relief solenoid
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving
    • Boom overload relief wire rubbed through near the boom foot, where the harness flexes with every lift

    Checks

    1. 1Measure the boom overload relief solenoid coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    3. 3Check the boom overload relief current on the service screen while raising a load; it should rise with load.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Check which valve the code names (relief 1, relief 2, breaker relief, boom overload, SJ or SZ) and unplug only that one
  2. 2Measure the coil resistance against the manual: open or very high is a burnt coil, far below is shorted turns
  3. 3Check the harness for a short or break with both ends unplugged
  4. 4Read commanded and fed-back current on the service screen while the attachment is selected
  5. 5Swap the SJ and SZ plugs only if the manual allows, and see whether the code moves with the coil

Causes

  • Proportional coil open or with shorted turns
  • Wire rubbed through along the boom and shorted or broken
  • Connector corroded or loose, adding resistance
  • Controller output stage not driving correctly

Most codes here: real condition (13 of 18)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: The attachment runs at the wrong relief pressure, weak or too aggressive, or the optional function the valve unit controls does not engage or stays engaged.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.