Develon · Hydraulic valve drivers

Develon Wheel loader valves, solenoids and relays fault codes

Electronic main control valve proportional valves, cooling fan and auxiliary valves, magnets and the starter relay on the H-series (H200 to H550) wheel loader table. They are driven directly by the loader controller.

FaultCheckV010Develon · Wheel loader valves, solenoids and relays
Code shows hereFAULTV010

Where this code shows

Switch the key on and open the monitor fault or service menu on the gauge panel to see active codes.

What do these codes mean?

Develon codes V010 to V022 are all about the wheel loader valves, solenoids and relays. None needs an immediate stop. Start with this check: match the code name to the function that is not working.

How urgent are they?

None of the 12 codes here means stop now; all 12 can wait until the shift ends, but find the cause before the next one.

  • Check soon12

What should I check first?

Match the code name to the function that is not working.

Shared checks

12 of 12

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Develon V010Cooling Fan Proportional Valve

    The cooling fan proportional valve (the first valve in the wheel loader table) sets the fan speed.· Lost message
    Check soon

    Causes

    • Open or shorted valve coil
    • Wiring or connector damage
    • Controller output fault

    Checks

    1. 1Disconnect the valve and measure coil resistance, comparing it with the manual.
    2. 2Check the harness for chafe where it runs to the fan motor.
    3. 3Watch fan speed change as temperature changes after clearing the code.
    4. 4Check the supply fuse and ground at the valve connector.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Develon V011Auxiliary Proportional Valve

    Same failure as V010 on the auxiliary proportional valve, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the auxiliary proportional valve or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the auxiliary proportional valve connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V011 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V012Electronic MCV Boom Raise Proportional Valve

    Same failure as V010 on the electronic mcv boom raise proportional valve, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the electronic mcv boom raise proportional valve or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the electronic mcv boom raise proportional valve connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V012 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V013Electronic MCV Boom Float Proportional Valve

    Same failure as V010 on the electronic mcv boom float proportional valve, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the electronic mcv boom float proportional valve or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the electronic mcv boom float proportional valve connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V013 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V014Electronic MCV Bucket Crowd Proportional Valve

    Same failure as V010 on the electronic mcv bucket crowd proportional valve, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the electronic mcv bucket crowd proportional valve or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the electronic mcv bucket crowd proportional valve connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V014 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V015Electronic MCV Bucket Dump Proportional Valve

    Same failure as V010 on the electronic mcv bucket dump proportional valve, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the electronic mcv bucket dump proportional valve or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the electronic mcv bucket dump proportional valve connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V015 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V016Electronic MCV Option Proportional Valve1

    Same failure as V010 on the electronic mcv option proportional valve1, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the electronic mcv option proportional valve1 or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the electronic mcv option proportional valve1 connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V016 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V017Electronic MCV Option Proportional Valve2

    Same failure as V010 on the electronic mcv option proportional valve2, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the electronic mcv option proportional valve2 or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the electronic mcv option proportional valve2 connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V017 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V018Reverse Fan Solenoid Valve

    Same failure as V010 on the reverse fan solenoid valve, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the reverse fan solenoid valve or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the reverse fan solenoid valve connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V018 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V019Unloading Solenoid Valve

    Same failure as V010 on the unloading solenoid valve, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the unloading solenoid valve or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the unloading solenoid valve connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V019 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V020Auxiliary Solenoid Valve 2

    Same failure as V010 on the auxiliary solenoid valve 2, a different part of the same kind as the cooling fan proportional valve.· Other
    Check soon

    Causes

    • Fault in the auxiliary solenoid valve 2 or its wiring
    • Any cause listed under V010

    Checks

    1. 1Check the auxiliary solenoid valve 2 connector and wiring first, then follow the checks listed under V010.
    2. 2Clear the code and confirm whether V020 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V022Starter Relay

    The starter relay output of the wheel loader controller.· Other
    Check soon

    Causes

    • Failed relay or contacts
    • Loose or corroded socket
    • Open or shorted drive wire
    • Blown fuse

    Checks

    1. 1Swap the relay with an identical one.
    2. 2Measure supply and ground at the socket while starting.
    3. 3Check the drive wire for continuity.
    4. 4Inspect the socket for heat marks and corrosion.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Match the code name to the function that is not working.
  2. 2Unplug the valve or relay and measure coil resistance against the manual.
  3. 3Check battery voltage and fuses with the key on.
  4. 4Inspect harness and connectors near the valve block for oil and chafe.

Causes

  • Open or shorted valve coil or relay
  • Wiring or connector damage near the valve block
  • Blown fuse or supply fault
  • Controller output fault

When to stop

You'll notice: A bucket, boom or auxiliary movement is weak or missing, or the fan or starter does not act, and the V code shows on the monitor.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.