Develon On/off solenoid valves fault codes

On/off solenoids that switch breaker flow, the power-boost relief, travel speed, fan reversal, pump combining, bypass cut-off and the swing brake. Each is either fully driven or off by the controller.

FaultCheckV000223Develon · On/off solenoid valves
Code shows hereFAULTV000223

Where this code shows

Switch the key on and open the monitor fault or service menu on the gauge panel to see active codes.

What do these codes mean?

Develon codes V000223 to V000233 are all about the on/off solenoid valves. None needs an immediate stop. Start with this check: identify the solenoid from the code title and find it on the valve block.

How urgent are they?

None of the 11 codes here means stop now; all 11 can wait until the shift ends, but find the cause before the next one.

  • Check soon11

What should I check first?

Identify the solenoid from the code title and find it on the valve block.

Shared checks

11 of 11

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Develon V000223Breaker operating S/V

    The breaker operating solenoid is an on/off valve that sends oil to a hydraulic hammer.· Open circuit
    Check soon

    Causes

    • Open or shorted solenoid coil
    • Failed fuse or relay feeding the solenoid
    • Corroded connector at the valve block
    • Controller output stage fault

    Checks

    1. 1Measure the coil resistance with the connector unplugged and compare with the manual.
    2. 2Check the circuit fuse and battery voltage at the connector with the breaker mode selected.
    3. 3Listen for a click at the valve when the breaker pedal or switch is used; a silent coil with good voltage means a bad coil.
    4. 4Inspect the wires along the boom and valve block for chafing.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Develon V000224Relief pressure up S/V (B)

    Same failure as V000223 on the relief pressure up s/v (b), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the relief pressure up s/v (b) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the relief pressure up s/v (b) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000224 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000225High speed S/V (C)

    Same failure as V000223 on the high speed s/v (c), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the high speed s/v (c) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the high speed s/v (c) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000225 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000226Breaker select S/V (D)

    Same failure as V000223 on the breaker select s/v (d), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the breaker select s/v (d) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the breaker select s/v (d) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000226 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000227Reverse fan S/V (E)

    Same failure as V000223 on the reverse fan s/v (e), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the reverse fan s/v (e) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the reverse fan s/v (e) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000227 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000228Cruise S/V (F)

    Same failure as V000223 on the cruise s/v (f), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the cruise s/v (f) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the cruise s/v (f) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000228 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000229Forward S/V (G)

    Same failure as V000223 on the forward s/v (g), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the forward s/v (g) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the forward s/v (g) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000229 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000230Reverse S/V (H)

    Same failure as V000223 on the reverse s/v (h), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the reverse s/v (h) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the reverse s/v (h) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000230 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V0002312-pump SELECT S/V (I)

    Same failure as V000223 on the 2-pump select s/v (i), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the 2-pump select s/v (i) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the 2-pump select s/v (i) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000231 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000232Bypass cut off S/V (J)

    Same failure as V000223 on the bypass cut off s/v (j), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the bypass cut off s/v (j) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the bypass cut off s/v (j) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000232 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000233Swing brake release S/V (K)

    Same failure as V000223 on the swing brake release s/v (k), a different part of the same kind as the breaker operating s/v.· Other
    Check soon

    Causes

    • Fault in the swing brake release s/v (k) or its wiring
    • Any cause listed under V000223

    Checks

    1. 1Check the swing brake release s/v (k) connector and wiring first, then follow the checks listed under V000223.
    2. 2Clear the code and confirm whether V000233 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Identify the solenoid from the code title and find it on the valve block.
  2. 2Measure the coil resistance with the connector unplugged and compare with the manual.
  3. 3Check the supply fuse and battery voltage at the connector with the key on.
  4. 4Listen for a click when the function is selected; a silent coil with good voltage means a bad coil.
  5. 5Inspect the harness for chafing against the valve block and frame.

Causes

  • Open or shorted solenoid coil
  • Failed fuse or relay feeding the solenoid
  • Connector corrosion at the valve
  • Controller output stage fault

When to stop

You'll notice: The function the solenoid controls does not switch (no breaker, no high-speed travel, swing brake stuck) and the code appears on the monitor.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.