EF Logo

Develon · Hydraulic valve drivers

Develon Pump and flow control proportional valves fault codes

Proportional valves that the machine controller drives with a variable current. They set the delivery of the main pumps and trim flow to the swing and two-way functions, so they decide how fast and how hard the machine works.

FaultCheckV000210Develon · Pump and flow control proportional valves
Code shows hereFAULTV000210

Where this code shows

Switch the key on and open the monitor fault or service menu on the gauge panel to see active codes.

What do these codes mean?

Develon codes V000210 to V000216 are all about the pump and flow control proportional valves. None needs an immediate stop. Start with this check: read the code on the monitor, clear it, and see if it returns immediately or only under load.

How urgent are they?

None of the 7 codes here means stop now; all 7 can wait until the shift ends, but find the cause before the next one.

  • Check soon7

What should I check first?

Read the code on the monitor, clear it, and see if it returns immediately or only under load.

Shared checks

7 of 7

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Develon V000210Pump P/V (A)

    The controller reports a fault on the pump P/V (A) output, the proportional valve that regulates the first main pump.· Other
    Check soon

    Causes

    • Open or shorted coil on the pump A regulator valve
    • Chafed or crushed wire between the controller and the pump
    • Water or oil inside the regulator connector
    • Controller output driver or ground fault

    Checks

    1. 1Unplug the pump A regulator valve and measure the coil resistance, comparing it with the service manual figure for your model.
    2. 2Trace the wires from the controller to the pump for chafing, especially where they pass over the pump housing.
    3. 3Reseat the connector, looking for pushed-back pins and green corrosion, then clear the code.
    4. 4Check whether the matching pump B code (V000211) also appears, which would point to a shared supply or controller fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000211Pump P/V (B)

    The controller reports a fault on the pump P/V (B) output, the proportional valve for the second main pump.· Lost message
    Check soon

    Causes

    • Open or shorted coil on the pump B regulator valve
    • Wire damage or a loose pin in the pump B harness branch
    • Moisture or hydraulic oil in the valve connector
    • Controller output fault on that channel

    Checks

    1. 1Measure the pump B regulator coil with the connector unplugged and compare it with the manual figure for your model.
    2. 2Swap the connectors of pump A and pump B valves, if they match, and see whether the fault moves to the other code.
    3. 3Inspect the pump B harness for rub points and a tight, dry connector seal.
    4. 4Confirm your machine uses the DX-3 table before acting, because V211 on a DX225LCA points to the cooling fan valve.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Develon V000212Flow control P/V (C) 2-way lh-h

    Same failure as V000210 on the flow control p/v (c) 2-way lh-h, a different part of the same kind as the pump p/v (a).· Other
    Check soon

    Causes

    • Fault in the flow control p/v (c) 2-way lh-h or its wiring
    • Any cause listed under V000210

    Checks

    1. 1Check the flow control p/v (c) 2-way lh-h connector and wiring first, then follow the checks listed under V000210.
    2. 2Clear the code and confirm whether V000212 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000213Flow control P/V (D) 2-way rh-h

    Same failure as V000210 on the flow control p/v (d) 2-way rh-h, a different part of the same kind as the pump p/v (a).· Other
    Check soon

    Causes

    • Fault in the flow control p/v (d) 2-way rh-h or its wiring
    • Any cause listed under V000210

    Checks

    1. 1Check the flow control p/v (d) 2-way rh-h connector and wiring first, then follow the checks listed under V000210.
    2. 2Clear the code and confirm whether V000213 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000214Flow control P/V (E) rotating cw

    Same failure as V000210 on the flow control p/v (e) rotating cw, a different part of the same kind as the pump p/v (a).· Other
    Check soon

    Causes

    • Fault in the flow control p/v (e) rotating cw or its wiring
    • Any cause listed under V000210

    Checks

    1. 1Check the flow control p/v (e) rotating cw connector and wiring first, then follow the checks listed under V000210.
    2. 2Clear the code and confirm whether V000214 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000215Flow control P/V (F) rotating ccw

    Same failure as V000210 on the flow control p/v (f) rotating ccw, a different part of the same kind as the pump p/v (a).· Other
    Check soon

    Causes

    • Fault in the flow control p/v (f) rotating ccw or its wiring
    • Any cause listed under V000210

    Checks

    1. 1Check the flow control p/v (f) rotating ccw connector and wiring first, then follow the checks listed under V000210.
    2. 2Clear the code and confirm whether V000215 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000216Flow control P/V (G)

    Same failure as V000210 on the flow control p/v (g), a different part of the same kind as the pump p/v (a).· Other
    Check soon

    Causes

    • Fault in the flow control p/v (g) or its wiring
    • Any cause listed under V000210

    Checks

    1. 1Check the flow control p/v (g) connector and wiring first, then follow the checks listed under V000210.
    2. 2Clear the code and confirm whether V000216 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Read the code on the monitor, clear it, and see if it returns immediately or only under load.
  2. 2Unplug the valve connector and measure coil resistance against the manual figure for your model.
  3. 3Inspect the harness along its full length for rub points, then wiggle-test with the engine off and key on.
  4. 4Check the connector pins for green corrosion or pushed-back terminals and reseat them.
  5. 5Swap the valve with a matching one (if two of the same type exist) to see whether the fault follows.

Causes

  • Open or shorted proportional coil
  • Chafed harness at the valve block or pump regulator
  • Corroded or wet connector on the valve
  • Controller output driver or ground fault

When to stop

You'll notice: The monitor shows the code and the affected function may feel slow, weak or jerky.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.