These codes say that data from another control unit (TCM, ICUC, VRDU, IPPC, ABS or the ACM data set) is missing, late or not believable. The wiring may be fine and the fault may sit in the other module.

FaultCheckSPN 513FMI 9Detroit · Module data timeouts and plausibility
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.

What do these codes mean?

Detroit codes SPN 513 FMI 9 to SPN 521004 FMI 14 are all about the module data timeouts and plausibility. The most common failure type is part or controller (8 of 18); none needs an immediate stop. Start with this check: read which module the code names and check whether that module also has stored faults.

How urgent are they?

None of the 18 codes here means stop now; all 18 can wait until the shift ends, but find the cause before the next one.

  • Check soon18

What should I check first?

Read which module the code names and check whether that module also has stored faults.

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Detroit SPN 513 FMI 9Actual Torque Signal Not Available via CAN

    Detroit lists SPN 513 FMI 9 as "Actual Torque Signal Not Available via CAN".· Lost message
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3Check the engine torque message on the CAN with the transmission connected and see whether the MCM transmits it.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 523 FMI 13J1939 Transmission Current Gear Signal is Missing

    Detroit lists SPN 523 FMI 13 as "J1939 Transmission Current Gear Signal is Missing".· Part or controller
    Check soon

    Causes

    • Software mismatch among modules
    • Wiring or connector fault on the data link

    Checks

    1. 1Compare the software versions of the modules.
    2. 2Check the data link wiring for chafing and corrosion.
    3. 3Check the transmission controller power and the J1939 wiring, since the engine is not receiving the current gear message.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 523 FMI 19J1939 Transmission Current Gear Signal is Erratic

    Detroit lists SPN 523 FMI 19 as "J1939 Transmission Current Gear Signal is Erratic".· Lost message
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3Read the gear signal while shifting; an erratic value suggests a noisy bus or a transmission controller fault.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 1243 FMI 12ABS Data Not Plausible

    Detroit lists SPN 1243 FMI 12 as "ABS Data Not Plausible".· Part or controller
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3Compare the ABS data in the tool with the wheel speeds and check the ABS controller for its own codes.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 1243 FMI 14ABS Faults Restricts Automatic Gear Selection Functionality

    Detroit lists SPN 1243 FMI 14 as "ABS Faults Restricts Automatic Gear Selection Functionality".· Lost message
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3Fix the ABS faults first, because the transmission restricts automatic gear selection until the ABS is healthy.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 1482 FMI 12TCM Data not Plausible

    Same failure as SPN 1243 FMI 12 ("ABS Data Not Plausible") on a sibling part: Detroit lists SPN 1482 FMI 12 as "TCM Data not Plausible".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 1243 FMI 12, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 1243 FMI 12, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 1482 FMI 14TCM Not Transmitting on J1939 or Malfunctioning

    Detroit lists SPN 1482 FMI 14 as "TCM Not Transmitting on J1939 or Malfunctioning".· Other
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3Check that the transmission controller is powered, transmitting on J1939 and not stuck in a fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Detroit SPN 1483 FMI 2MCM Data not Plausible

    Same failure as SPN 1243 FMI 12 ("ABS Data Not Plausible") on a sibling part: Detroit lists SPN 1483 FMI 2 as "MCM Data not Plausible".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 1243 FMI 12, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 1243 FMI 12, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 1483 FMI 12MCM data - CAN timeout

    Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 1483 FMI 12 as "MCM data - CAN timeout".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 1590 FMI 12VRDU Data - CAN Timeout

    Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 1590 FMI 12 as "VRDU Data - CAN Timeout".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 3236 FMI 9Exhaust Mass Signal Not Available via CAN

    Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 3236 FMI 9 as "Exhaust Mass Signal Not Available via CAN".· Lost message
    Check soon

    Causes

    • The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 3613 FMI 12ICUC Data - CAN Timeout

    Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 3613 FMI 12 as "ICUC Data - CAN Timeout".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 4206 FMI 2J1939 TSC1 Message Counter Failure

    Detroit lists SPN 4206 FMI 2 as "J1939 TSC1 Message Counter Failure".· Erratic or implausible
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3The TSC1 torque message counter is wrong; check which module sends the torque request and the bus quality.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 4207 FMI 2J1939 TSC1 Checksum Failure

    Detroit lists SPN 4207 FMI 2 as "J1939 TSC1 Checksum Failure".· Erratic or implausible
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3The TSC1 checksum failed; check the sender module and the bus for noise.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 520222 FMI 12ACM Data not Plausible

    Same failure as SPN 1243 FMI 12 ("ABS Data Not Plausible") on a sibling part: Detroit lists SPN 520222 FMI 12 as "ACM Data not Plausible".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 1243 FMI 12, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 1243 FMI 12, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 520230 FMI 12IPPC Data - CAN Timeout

    Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 520230 FMI 12 as "IPPC Data - CAN Timeout".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 520232 FMI 9NOx Mass Signal Not Available via Controller Area Network

    Same failure as SPN 513 FMI 9 ("Actual Torque Signal Not Available via CAN") on a sibling part: Detroit lists SPN 520232 FMI 9 as "NOx Mass Signal Not Available via Controller Area Network".· Lost message
    Check soon

    Causes

    • The causes listed under SPN 513 FMI 9, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 513 FMI 9, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 521004 FMI 14Automatic Gear Selection - Incompatible or Missing Dataset

    Detroit lists SPN 521004 FMI 14 as "Automatic Gear Selection - Incompatible or Missing Dataset".· Other
    Check soon

    Causes

    • Power or ground missing at that module
    • CAN wiring fault between the modules

    Checks

    1. 1Check the power and ground feeds of the module that is not reporting.
    2. 2Check the CAN wiring and terminating resistance.
    3. 3The gear selection data set is missing or incompatible; load the right data set.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Read which module the code names and check whether that module also has stored faults.
  2. 2Check the power and ground feeds of the module that stopped reporting.
  3. 3Compare the software versions of the modules in the diagnostic tool.
  4. 4Look at the CAN wiring to that module for chafing and corrosion.

Causes

  • The other module has lost power, reset or failed
  • Software or parameter mismatch between the modules
  • CAN wiring chafed or a connector corroded
  • A message counter or checksum error caused by a noisy link

Most common here: part or controller (8 of 18)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: Gear selection, cruise, dash lamps or the aftertreatment may misbehave, and the check-engine lamp comes on.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.