Cummins Coolant level sensor and fan control fault codes

A level sensor in the surge tank or radiator tells the ECM when coolant is low. The ECM drives the cooling fan clutch or hydraulic fan and reads fan speed requests and the A/C high-pressure switch on some vehicles.

FaultCheck195Cummins · Coolant level sensor 1 circuit
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.

What do these codes mean?

Cummins codes 195 to 14377 are all about the coolant level sensor and fan control. The most common failure type is shorted low (5 of 17); 1 needs an immediate stop. Start with this check: check the coolant level when cold and top up with the correct mixture.

How urgent are they?

1 of 17 codes here means stop now; 15 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Stop now1
  • Check soon15
  • Info1

What should I check first?

Check the coolant level when cold and top up with the correct mixture

Shared checks

17 of 17

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Coolant level sensor 1 circuit3 codes

    • Cummins 195Coolant level sensor 1 circuit: Voltage high / shorted high

      The ECM sees the coolant level sensor 1 circuit signal circuit above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V reference or battery voltage in the harness
      • Open sensor return wire letting the signal float up
      • Sensor failed high or its connector is corroded

      Checks

      1. 1Read the live coolant level sensor 1 circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
      2. 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
      3. 3With the key off, test the signal wire for continuity to the reference and to battery positive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Coolant level sensor 1 circuit - voltage high (shorted to a high source)

    • Cummins 196Coolant level sensor 1 circuit: Voltage low / shorted low

      The ECM sees the coolant level sensor 1 circuit signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live coolant level sensor 1 circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Coolant level sensor 1 circuit - voltage low (shorted to a low source)

    • Cummins 6523Coolant level sensor 1 circuit: Voltage low / shorted low

      The ECM sees the coolant level sensor 1 circuit signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live coolant level sensor 1 circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Coolant level sensor 1 circuit - voltage low (shorted to a low source)

  • Fan control circuit3 codes

    • Cummins 2377Fan control circuit: Voltage high

      The ECM sees the fan clutch driver output higher than it commanded, which points to a driver wire touching a supply or an open return on the fan solenoid.· Shorted high
      Check soon

      Causes

      • Fan driver wire shorted to a switched power wire in the harness at the fan shroud
      • Open return on the fan solenoid
      • Fan clutch solenoid failed in a stuck-on state

      Checks

      1. 1Key on, engine off: measure the fan driver pin at the unplugged connector; battery voltage there points to a short to power
      2. 2Check the continuity of the fan return wire back to the ECM
      3. 3Command the fan in INSITE and watch whether the fan changes speed
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

    • Cummins 6263Fan control circuit: Voltage high / shorted high

      The ECM sees the fan control circuit drive circuit with voltage above the expected level.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery or a switched power feed
      • Open ground or return path on the component
      • Component winding failed or its connector damaged

      Checks

      1. 1Unplug the fan control circuit connector, key on, and measure the output pin to ground; battery voltage with nothing connected points to a short to power
      2. 2Inspect the harness for a rubbed wire or damaged splice touching a power feed
      3. 3Measure the component resistance across its pins to rule out an open winding
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Fan control circuit - voltage high (shorted to a high source)

    • Cummins 6264Fan control circuit: Voltage low / shorted low

      The ECM sees the fan control circuit drive circuit with voltage below the expected level.· Shorted low
      Check soon

      Causes

      • Output wire shorted to ground or chafed through to the chassis
      • Component winding shorted internally
      • Connector corroded and bridging the pins

      Checks

      1. 1Unplug the fan control circuit connector and measure the output pin to ground; a short here means the harness is at fault
      2. 2Measure the component resistance across its pins; a very low reading means a shorted winding
      3. 3Inspect the connector for moisture and bridged terminals
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Fan control circuit - voltage low (shorted to a low source)

  • Coolant level2 codes

    • Cummins 2448Coolant level: Below normal· least severe

      The coolant level is below its normal operating range and the ECM rates it as least severe.· Real condition
      Info

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live coolant level with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Coolant level - below normal - least severe

    • Cummins 3366Coolant level: Below normal· moderately severe

      The coolant level is below its normal operating range and the ECM rates it as moderately severe.· Real condition
      Check soon

      Causes

      • The monitored condition really is too low because of the system it measures
      • A related fault that set first and is pushing the reading out of range

      Checks

      1. 1Compare the live coolant level with a second reading or gauge to see whether the condition is real
      2. 2Read the freeze-frame for speed, load and temperature when the code set
      3. 3Clear any other active codes first and retest under load
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Coolant level - below normal - moderately severe

  • Engine coolant level sensor No. 2 circuit2 codes

    • Cummins 4865Engine coolant level sensor No. 2 circuit: Voltage high / shorted high

      The ECM sees the engine coolant level sensor No. 2 circuit signal circuit above its normal voltage band.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V reference or battery voltage in the harness
      • Open sensor return wire letting the signal float up
      • Sensor failed high or its connector is corroded

      Checks

      1. 1Read the live engine coolant level sensor No. 2 circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
      2. 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
      3. 3With the key off, test the signal wire for continuity to the reference and to battery positive
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine coolant level sensor No. 2 circuit - voltage high (shorted to a high source)

    • Cummins 4866Engine coolant level sensor No. 2 circuit: Voltage low / shorted low

      The ECM sees the engine coolant level sensor No. 2 circuit signal circuit below its normal voltage band.· Shorted low
      Check soon

      Causes

      • Signal wire shorted to ground in the harness
      • Open 5 V reference wire so the signal collapses
      • Sensor failed low or its connector is wet or corroded

      Checks

      1. 1Read the live engine coolant level sensor No. 2 circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
      2. 2Unplug the sensor and check that the 5 V reference arrives at the connector
      3. 3With the key off, test the signal wire for a short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine coolant level sensor No. 2 circuit - voltage low (shorted to a low source)

  • A/C high pressure fan switch2 codes

    • Cummins 14328A/C high pressure fan switch: Out of calibration

      The ECM reports the A/C high pressure fan switch as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Part or controller
      Check soon

      Causes

      • Parameter set for a feature that is not fitted
      • Wrong or outdated calibration in the ECM
      • Source module sending an invalid value

      Checks

      1. 1Compare the ECM parameters with the vehicle equipment
      2. 2Reflash the ECM with the correct calibration
      3. 3Read the source module for its own codes
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 14329A/C high pressure fan switch: Abnormal update rate

      The ECM is not receiving fresh data for the A/C high pressure fan switch at the expected rate.· Lost message
      Check soon

      Causes

      • Data link wiring fault or a poor connector contact
      • The module that sends the message is offline or failing
      • Power or ground problem at the sending module

      Checks

      1. 1Look for other modules reporting timeouts to find where the link is broken
      2. 2Check the data link wiring, connectors and terminators
      3. 3Read the sending module for its own codes
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine fan 1 requested percent speed2 codes

    • Cummins 14376Engine fan 1 requested percent speed: Out of calibration

      The ECM reports the engine fan 1 requested percent speed as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controller
      Check soon

      Causes

      • Sensor or device out of tolerance
      • Wrong calibration or learn data after a repair

      Checks

      1. 1Check whether a learn or calibration procedure is needed after the last repair
      2. 2Compare with a related sensor and replace the part if the offset is real
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Cummins 14377Engine fan 1 requested percent speed: Abnormal update rate

      The ECM is not receiving fresh data for the engine fan 1 requested percent speed at the expected rate, so the value is late or has stopped updating.· Erratic or implausible
      Check soon

      Causes

      • Wiring or connector contact fault
      • Sending module offline or failing

      Checks

      1. 1Check the wiring and connector for loose terminals
      2. 2Look for related data link or module faults
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Other codes3 codes

    • Cummins 197Coolant level low· moderately severe

      The coolant level sensor reports the coolant level below the warning limit.· Other
      Check soon

      Causes

      • Coolant leak
      • Low coolant after service
      • Air pocket in the system

      Checks

      1. 1Check the coolant level cold and top up with the correct mixture
      2. 2Pressure-test the cooling system to find external leaks and check the oil for coolant
      3. 3Look at the water pump, hoses, heater lines and radiator for leaks
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

      Source wording:Coolant level low - moderately severe

    • Cummins 235Coolant level very low· most severe

      The coolant level is below the lowest limit.· Real condition
      Stop now

      Causes

      • Severe coolant leak or boil-over
      • Burst hose or radiator damage
      • Head gasket or EGR cooler leak

      Checks

      1. 1Stop the engine and check the coolant level when cool
      2. 2Look under the machine and around the hoses, radiator and water pump for a coolant leak
      3. 3Pressure-test the cooling system and check for exhaust in the coolant
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Coolant level very low - most severe

    • Cummins 245Fan clutch driver shorted low or driver voltage low

      The ECM drives the fan clutch driver but sees its output pulled to ground.· Shorted low
      Check soon

      Causes

      • Fan clutch solenoid wire shorted to ground near the fan
      • Solenoid coil shorted
      • Connector water-logged

      Checks

      1. 1Command the fan in INSITE and see whether the clutch changes speed
      2. 2Unplug the fan connector; a code change means the solenoid was shorted
      3. 3Measure the fan clutch solenoid coil resistance at its connector and compare it with the service value
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Check the coolant level when cold and top up with the correct mixture
  2. 2Check the fan clutch circuit resistance and wiring for shorts
  3. 3Look for leaks at hoses, radiator and the water pump weep hole
  4. 4Test the fan operation in INSITE and listen for engagement
  5. 5Check the sensor wiring and connector for damage
  6. 6Check the A/C pressure switch and its signal on the data link
  7. 7Test sensor operation by raising and lowering the level where possible

Causes

  • Genuinely low coolant from a leak or recent service
  • Open or shorted fan clutch circuit
  • Aerated coolant giving false low readings
  • Fan drive solenoid failed

Most common here: shorted low (5 of 17)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: A low-level warning or derate may appear.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.