Bobcat · Controller
Bobcat Main, cab and mid controllers fault codes
The main controller runs the machine functions, with cab and mid controllers handling the operator and cab side on larger models. Codes cover memory failure, interrupted power, not programmed, software incompatible or outdated, authentication failure and loss of communication.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes 30-28 to M7497 are all about the main, cab and mid controllers. The most common failure type is part or controller (12 of 26); none needs an immediate stop. Start with this check: check the supply and ground at the controller connector first; most no-communication codes are a power or CAN fault.
How urgent are they?
None of the 26 codes here means stop now; 24 can wait until the shift ends, but find the cause before the next one; 2 are information only.
- Check soon24
- Info2
What should I check first?
Check the supply and ground at the controller connector first; most no-communication codes are a power or CAN fault.
Shared checks26 of 26
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat 30-28Controller memory failure
The controller failure reports a memory failure: stored settings could not be read or written, so the machine control messages are not valid and functions are limited.· Part or controllerPart or controllerCheck soonCauses
- Controller memory corrupted by an interrupted write
- Controller failed internally
Checks
- 1Cycle the key, clear the code and see whether it returns.
- 2Reprogram the controller through the dealer service tool.
- 3Replace the controller if the code returns after reprogramming.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat 31-28Interrupted power failure
The failure lost its supply briefly while the machine was running, so the machine control messages are not valid and functions are limited. It also appears after a software update or a jump start.· Part or controllerPart or controllerCheck soonCauses
- Battery terminal or main ground loose
- Supply fuse or connector intermittent
- Low battery during cranking
Checks
- 1Check battery terminals and the main ground strap for tight clean connections.
- 2Check the controller supply fuse and connector for heat marks.
- 3Clear the code and watch whether it returns after the next start.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat 33-23Main controller not programmed
The main controller has no valid program loaded, so the controller will not run its functions and the machine may not run its functions and the panel may show a controller fault. This is set after a controller replacement or a failed update.· Part or controllerPart or controllerCheck soonCauses
- New or replaced controller never programmed
- Software update interrupted
- Memory corrupted
Checks
- 1Program the main controller with the dealer service tool and the correct software for the machine model.
- 2Check that supply stayed steady during the last update.
- 3After programming, calibrate and clear the code.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat U100A-08Machine control message failure
The controller stopped receiving valid messages from the machine control, so the machine control messages are not valid and functions are limited. Messages are sent continuously and a missing or corrupt one sets this code.· OtherOtherCheck soonCauses
- Data wire chafed or loose
- Supply to the unit interrupted
- Unit failed or software mismatch
Checks
- 1Check supply and ground at the machine control connector.
- 2Check the message wiring for chafing and bent pins.
- 3Update the software through the dealer if a mismatch is suspected.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat U1051-00Cab controller interrupted power failure
The cab controller failure lost its supply briefly while the machine was running, so cab functions such as lights, switches and display feeds are lost. It also appears after a software update or a jump start.· Part or controllerPart or controllerCheck soonCauses
- Battery terminal or main ground loose
- Supply fuse or connector intermittent
- Low battery during cranking
Checks
- 1Check battery terminals and the main ground strap for tight clean connections.
- 2Check the controller supply fuse and connector for heat marks.
- 3Clear the code and watch whether it returns after the next start.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat U1052-00Power failure
The controller reports a failure on the power without saying whether it is open, shorted or stuck, so the machine control messages are not valid and functions are limited. It is a general output fault rather than one failure mode.· OtherOtherCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector at the controller connector
- Intermittent break in the harness
- Controller output stage failed
Checks
- 1Read the other active codes for the power; a short or open code beside this one narrows the cause.
- 2Reseat the connector at the controller connector and clear the code to see whether it returns.
- 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat U1071-00Cab controller software updated
This is a status message, not a fault: the cab controller software has just been updated, and the controller records it.· Part or controllerPart or controllerInfoCauses
- Software update was completed
- Controller restarted and logged the new version
Checks
- 1Restart the machine and confirm the message does not return.
- 2Check that the other controllers also show the new version.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat U1092-08Cab controller no communication
The controller has lost communication with the cab controller, so cab functions such as lights, switches and display feeds are lost. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the cab controller connector
Checks
- 1Measure supply and ground at the cab controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the cab controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat U1092-51Cab controller not programmed
The cab controller has no valid program loaded, so the controller will not run its functions and cab functions such as lights, switches and display feeds are lost. This is set after a controller replacement or a failed update.· OtherOtherCheck soonCauses
- New or replaced controller never programmed
- Software update interrupted
- Memory corrupted
Checks
- 1Program the cab controller with the dealer service tool and the correct software for the machine model.
- 2Check that supply stayed steady during the last update.
- 3After programming, calibrate and clear the code.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat U1092-57Cab controller software version error
The controller reports a failure on the cab controller software version without saying whether it is open, shorted or stuck, so cab functions such as lights, switches and display feeds are lost. It is a general output fault rather than one failure mode.· Part or controllerPart or controllerCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector at the cab controller connector
- Intermittent break in the harness
- Controller output stage failed
Checks
- 1Read the other active codes for the cab controller software version; a short or open code beside this one narrows the cause.
- 2Reseat the connector at the cab controller connector and clear the code to see whether it returns.
- 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat U1093-08Mid controller no communication
The controller has lost communication with the mid controller, so functions handled by the mid controller are lost. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the mid controller connector
Checks
- 1Measure supply and ground at the mid controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the mid controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat U1093-51Mid controller not calibrated
The mid controller needs a calibration before it can run normally, so functions handled by the mid controller are lost. This is set after a part or controller is replaced or after a reset.· Lost messageLost messageCheck soonCauses
- Controller or sensor replaced
- Calibration lost after a reset or reprogramming
Checks
- 1Run the mid controller calibration from the service menu.
- 2Check the machine is warm and on level ground as the procedure requires.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat U1093-57Mid controller software version error
The controller reports a failure on the mid controller software version without saying whether it is open, shorted or stuck, so functions handled by the mid controller are lost. It is a general output fault rather than one failure mode.· Part or controllerPart or controllerCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector at the mid controller connector
- Intermittent break in the harness
- Controller output stage failed
Checks
- 1Read the other active codes for the mid controller software version; a short or open code beside this one narrows the cause.
- 2Reseat the connector at the mid controller connector and clear the code to see whether it returns.
- 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat H3028Controller memory failure
Controller memory failure: same fault as 30-28 (stored memory could not be read), here on the controller failure.· Part or controllerPart or controllerCheck soonCauses
- Controller memory corrupted by an interrupted write
- Controller failed internally
Checks
- 1Cycle the key, clear the code and reprogram if it returns.
- 2Test steps: see 30-28.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat H3128Interrupted power failure
Interrupted power failure: same fault as 31-28 (the controller supply was briefly lost), here on the failure.· OtherOtherCheck soonCauses
- Battery terminal or main ground loose
- Supply fuse or connector intermittent
Checks
- 1Check battery terminals and the controller supply fuse.
- 2Test steps: see 31-28.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M3128Interrupted power failure
Interrupted power failure: same fault as 31-28 (the controller supply was briefly lost), here on the failure.· OtherOtherCheck soonCauses
- Battery terminal or main ground loose
- Supply fuse or connector intermittent
Checks
- 1Check battery terminals and the controller supply fuse.
- 2Test steps: see 31-28.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat W3128Interrupted power failure
Interrupted power failure: same fault as 31-28 (the controller supply was briefly lost), here on the failure.· OtherOtherCheck soonCauses
- Battery terminal or main ground loose
- Supply fuse or connector intermittent
Checks
- 1Check battery terminals and the controller supply fuse.
- 2Test steps: see 31-28.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat W3304Main controller no communication
Main controller no communication: same fault as H7404 (the controller lost communication), here on the main controller.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
Checks
- 1Measure supply and ground at the main controller connector and check its data wires.
- 2Test steps: see H7404.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat H7404Main controller no communication
The controller has lost communication with the main controller, so the machine may not run its functions and the panel may show a controller fault. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the main controller connector
Checks
- 1Measure supply and ground at the main controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the main controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat L7404Main controller no communication
Main controller no communication: same fault as H7404 (the controller lost communication), here on the main controller.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
Checks
- 1Measure supply and ground at the main controller connector and check its data wires.
- 2Test steps: see H7404.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat R7404Main controller no communication
Main controller no communication: same fault as H7404 (the controller lost communication), here on the main controller.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
Checks
- 1Measure supply and ground at the main controller connector and check its data wires.
- 2Test steps: see H7404.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M7423Main controller not programmed
Main controller not programmed: same fault as 33-23 (no valid program is loaded), here on the main controller.· OtherOtherCheck soonCauses
- New or replaced controller never programmed
- Software update interrupted
Checks
- 1Program the main controller with the dealer service tool.
- 2Test steps: see 33-23.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M7472Main controller software incompatible
The software in the main controller does not match the rest of the machine, so the machine may not run its functions and the panel may show a controller fault. The controllers check each other's versions at start-up.· Part or controllerPart or controllerCheck soonCauses
- Controller replaced with a different software version
- Update applied to one controller only
- Wrong software file loaded
Checks
- 1Read the software versions of each controller on the service screen.
- 2Update the main controller to the version that matches the machine through the dealer service tool.
- 3Clear the code and restart to confirm the versions agree.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat M7473Main controller software outdated
The main controller is running older software than the machine now requires, so the machine may not run its functions and the panel may show a controller fault until it is updated.· Part or controllerPart or controllerCheck soonCauses
- Another controller was updated and this one was not
- Old unit fitted as a replacement
Checks
- 1Read the main controller software version on the service screen.
- 2Update it through the dealer service tool.
- 3Restart and confirm the code is gone.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat R7492Main controller authentication failed
The main controller failed failed authentication when the controllers checked each other, so the machine may not run its functions and the panel may show a controller fault. A replaced controller that was not set up for this machine causes it.· Part or controllerPart or controllerCheck soonCauses
- Controller replaced without matching security setup
- Wrong software loaded
Checks
- 1Have the dealer re-pair the main controller failed with the machine.
- 2Check that the correct controller part number is fitted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat M7497Main controller software updated
This is a status message, not a fault: the main controller software has just been updated, and the controller records it.· Part or controllerPart or controllerInfoCauses
- Software update was completed
- Controller restarted and logged the new version
Checks
- 1Restart the machine and confirm the message does not return.
- 2Check that the other controllers also show the new version.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Shared checks
Checks, in order
- 1Check the supply and ground at the controller connector first; most no-communication codes are a power or CAN fault.
- 2Read all controller codes together to see which controller dropped off the network.
- 3Check the CAN wiring and terminating resistors for breaks and water.
- 4After a controller or software change, run the dealer programming and calibration procedure.
- 5Replace a controller only after supply, ground and CAN are confirmed good.
Causes
- Controller not programmed or loaded with incompatible software
- Interrupted supply during a start or a software update
- CAN wiring fault or a controller with no power
- Controller internal failure
Most common here: part or controller (12 of 26)
Check power and ground at the module connector with the key on, then its fuses.
When to stop
You'll notice: The machine may not start or enable functions, a controller offline message shows, or functions stop after a software update.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list (cont.)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.