Bobcat · Controller
Bobcat Drive and ACS controllers fault codes
The drive controller runs the hydrostatic pumps and motors, and the ACS and AHC controller handles electronic lift control. Codes cover loss of communication, needing programming or calibration, interrupted power, calibration mode, and calibration passed or performed.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes C10D0-54 to D7599 are all about the drive and ACS controllers. The most common failure type is lost message (11 of 26); none needs an immediate stop. Start with this check: measure supply and ground at the drive controller connector and check its fuse.
How urgent are they?
None of the 26 codes here means stop now; 18 can wait until the shift ends, but find the cause before the next one; 8 are information only.
- Check soon18
- Info8
What should I check first?
Measure supply and ground at the drive controller connector and check its fuse.
Shared checks26 of 26
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat C10D0-54Drive pump not calibrated
The pump needs a calibration before it can run normally, so the machine will not drive or drive is limited. This is set after a part or controller is replaced or after a reset.· Lost messageLost messageCheck soonCauses
- Controller or sensor replaced
- Calibration lost after a reset or reprogramming
Checks
- 1Run the pump calibration from the service menu.
- 2Check the machine is warm and on level ground as the procedure requires.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat 32-04ACS not communicating with bobcat controller
The controller has lost communication with the with bobcat controller, so the machine will not drive or drive is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the drive controller connector
Checks
- 1Measure supply and ground at the with bobcat controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the drive controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat 32-23ACS not calibrated
ACS not calibrated: same fault as W3223 (a calibration is needed), here on the acs.· Part or controllerPart or controllerCheck soonCauses
- Controller or sensor replaced
- Calibration lost after a reset or reprogramming
Checks
- 1Run the acs calibration from the service menu.
- 2Test steps: see W3223.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat 32-41ACS no communication
The controller has lost communication with the acs, so electronic lift control is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the ACS controller connector
Checks
- 1Measure supply and ground at the acs connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the ACS controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat U1065-00Drive calibration passed
This is a status message, not a fault: the drive calibration passed.· Part or controllerPart or controllerInfoCauses
- Calibration finished with results inside limits
- Calibration was run after a part change
Checks
- 1Clear the message and restart the machine.
- 2Test the function the calibration covers.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat U1080-00Drive controller in calibration mode
Drive controller in calibration mode: same fault as D7598 (the controller is in calibration mode), here on the controller in.· Part or controllerPart or controllerInfoCauses
- Calibration was started from the service menu
- Calibration left unfinished
Checks
- 1Finish or cancel the controller in calibration and restart.
- 2Test steps: see D7598.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat W3223ACS calibration required
The acs needs a calibration before it can run normally, so electronic lift control is limited. This is set after a part or controller is replaced or after a reset.· Lost messageLost messageCheck soonCauses
- Controller or sensor replaced
- Calibration lost after a reset or reprogramming
Checks
- 1Run the acs calibration from the service menu.
- 2Check the machine is warm and on level ground as the procedure requires.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat W3224ACS calibration performed
This is a status message, not a fault: the acs calibration was carried out.· Part or controllerPart or controllerInfoCauses
- Calibration was run from the service menu
- A part change or reset called for it
Checks
- 1Clear the message and restart.
- 2Test the function the calibration covers.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat W3225ACS (ahc) calibration failed
The ahc calibration did not finish correctly, so the controller keeps the old or default values and electronic lift control is limited.· Part or controllerPart or controllerCheck soonCauses
- Hydraulic oil too cold or too hot for the procedure
- Sensor or valve fault stopping the sequence
- Calibration steps interrupted or done out of order
Checks
- 1Warm the machine and repeat the ahc calibration exactly as the service procedure describes.
- 2Clear other active codes before calibrating.
- 3Check the sensors and valves the procedure moves for sticking.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat W3241AHC no communication
The controller has lost communication with the ahc, so electronic lift control is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the ACS controller connector
Checks
- 1Measure supply and ground at the ahc connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the ACS controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat W3270ACS right hand drive short to ground
The controller reads the right hand drive circuit pulled to ground, so it cannot drive the load. The output is shut off and the machine will not drive or drive is limited until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the drive controller connector
- The controller supply shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the right hand drive output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the controller supply to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the drive controller connector.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat W3271ACS right hand drive short to battery
The controller reads the right hand drive circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the machine will not drive or drive is limited.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the drive controller connector and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the right hand drive at the drive controller connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the controller supply for chafing next to live supply wires and for melted insulation.
- 3Replace the controller supply only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat W3297ACS (ahc) controller programmed
This is a status message, not a fault: the ahc was programmed successfully.· OtherOtherInfoCauses
- Programming completed normally
- Controller was replaced or reflashed beforehand
Checks
- 1Restart the machine and clear the message.
- 2Run the calibration the controller asks for next.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7502Drive controller needs programming
The controller has no valid program loaded, so the controller will not run its functions and the machine will not drive or drive is limited. This is set after a controller replacement or a failed update.· OtherOtherCheck soonCauses
- New or replaced controller never programmed
- Software update interrupted
- Memory corrupted
Checks
- 1Program the controller with the dealer service tool and the correct software for the machine model.
- 2Check that supply stayed steady during the last update.
- 3After programming, calibrate and clear the code.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7504Drive no communication from drive controller
The controller has lost communication with the from drive controller, so the machine will not drive or drive is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the drive controller connector
Checks
- 1Measure supply and ground at the from drive controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the drive controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M7504Drive no communication
The controller has lost communication with the drive, so the machine will not drive or drive is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the drive controller connector
Checks
- 1Measure supply and ground at the drive connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the drive controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat W7504Drive controller no communication
The controller has lost communication with the controller, so the machine will not drive or drive is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the drive controller connector
Checks
- 1Measure supply and ground at the controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the drive controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat D7567Drive no communication from bobcat controller
The controller has lost communication with the from bobcat controller, so the machine will not drive or drive is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the drive controller connector
Checks
- 1Measure supply and ground at the from bobcat controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the drive controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat D7570Drive interrupted power (also occurs after software updates)
The also occurs after software updates lost its supply briefly while the machine was running, so the machine will not drive or drive is limited. It also appears after a software update or a jump start.· Part or controllerPart or controllerCheck soonCauses
- Battery terminal or main ground loose
- Supply fuse or connector intermittent
- Low battery during cranking
Checks
- 1Check battery terminals and the main ground strap for tight clean connections.
- 2Check the controller supply fuse and connector for heat marks.
- 3Clear the code and watch whether it returns after the next start.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat D7572Drive drive pump not calibrated
The drive pump needs a calibration before it can run normally, so the machine will not drive or drive is limited. This is set after a part or controller is replaced or after a reset.· Lost messageLost messageCheck soonCauses
- Controller or sensor replaced
- Calibration lost after a reset or reprogramming
Checks
- 1Run the drive pump calibration from the service menu.
- 2Check the machine is warm and on level ground as the procedure requires.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat D7576Drive no communication from ACS controller
The controller has lost communication with the from acs controller, so electronic lift control is limited. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the ACS controller connector
Checks
- 1Measure supply and ground at the from acs controller connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the ACS controller connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat D7587Drive software update required
The drive software must be updated before the machine will run normally, so the machine will not drive or drive is limited. The controller found a version older than the rest of the system requires.· Part or controllerPart or controllerCheck soonCauses
- Another controller was updated and this one was not
- Replacement unit fitted with old software
Checks
- 1Read the software version of the drive on the service screen.
- 2Update it through the dealer service tool, then restart.
- 3Confirm the code does not return after the update.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat D7590Drive drive calibration performed
This is a status message, not a fault: the drive calibration was carried out.· Part or controllerPart or controllerInfoCauses
- Calibration was run from the service menu
- A part change or reset called for it
Checks
- 1Clear the message and restart.
- 2Test the function the calibration covers.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat D7597Drive controller programmed
This is a status message, not a fault: the drive was programmed successfully.· OtherOtherInfoCauses
- Programming completed normally
- Controller was replaced or reflashed beforehand
Checks
- 1Restart the machine and clear the message.
- 2Run the calibration the controller asks for next.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7598Drive controller in calibration mode
This is a status message: the controller in is in calibration mode, so the machine will not drive or drive is limited until the calibration is finished or cancelled.· Part or controllerPart or controllerInfoCauses
- Calibration was started from the service menu
- Calibration left unfinished
Checks
- 1Finish the calibration or cancel it from the service menu.
- 2Restart the machine to leave calibration mode.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat D7599Drive controller in angle calibration mode
This is a status message: the controller in angle is in calibration mode, so the machine will not drive or drive is limited until the calibration is finished or cancelled.· Part or controllerPart or controllerInfoCauses
- Calibration was started from the service menu
- Calibration left unfinished
Checks
- 1Finish the calibration or cancel it from the service menu.
- 2Restart the machine to leave calibration mode.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Shared checks
Checks, in order
- 1Measure supply and ground at the drive controller connector and check its fuse.
- 2Check CAN wiring between the drive and main controllers.
- 3Run the drive pump calibration and angle calibration through the service tool.
- 4Note whether a code is a status message such as calibration passed, which is not a fault.
- 5Check for interrupted power codes after a flat battery or jump start.
Causes
- Drive controller supply or CAN connection lost
- Controller needs programming or pump calibration after replacement
- Software update interrupted
- Controller failed internally
Most common here: lost message (11 of 26)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: The machine will not drive or a calibration message shows; drive may be limited until the controller is programmed.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.