Bobcat · Electrical
Bobcat ECU power, switched power and key switch fault codes
The key switch and the relays and fused feeds behind it supply the engine ECU, the machine controllers and the switched outputs. A code here points at one of those feeds: the ECU power relay, a switched power output, or the key switch input, rather than at a component further down the line.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes B10D0-12 to M7748 are all about the eCU power, switched power and key switch. The most common failure type is shorted low (6 of 19); none needs an immediate stop. Start with this check: check the fuses for the ECU and switched power feeds, including the fuse holder terminals for heat discoloration.
How urgent are they?
None of the 19 codes here means stop now; all 19 can wait until the shift ends, but find the cause before the next one.
- Check soon19
What should I check first?
Check the fuses for the ECU and switched power feeds, including the fuse holder terminals for heat discoloration.
Shared checks19 of 19
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat B10D0-12Display switched power relay error on
The controller sees the display switched power relay switched on when it was commanded off, so the feed stays on after key off. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the display switched power relay at the relay socket in the fuse panel with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the relay and its socket energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B10D0-14Display switched power relay error off
The controller sees the display switched power relay off when it was commanded on, so the switched feed to the controller or display drops out. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The relay and its socket failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the display switched power relay circuit with the key on.
- 2Measure the resistance of the relay and its socket and look for an open or a short to its body.
- 3Command the function and measure voltage at the display switched power relay plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C100A-11ECU power short to ground
The controller reads the ecu power circuit pulled to ground, so it cannot drive the load. The output is shut off and the engine ECU loses its supply, so the engine stalls or will not start until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the ECU power connector
- The ECU supply circuit shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the ecu power output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the ECU supply circuit to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the ECU power connector.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C100A-12ECU power short to battery
The controller reads the ecu power circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the engine ECU loses its supply, so the engine stalls or will not start.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the ECU power connector and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the ecu power at the ECU power connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the ECU supply circuit for chafing next to live supply wires and for melted insulation.
- 3Replace the ECU supply circuit only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat C100A-13ECU power open circuit
The controller sees an open circuit on the ecu power, so no current can flow through it and the engine ECU loses its supply, so the engine stalls or will not start. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the ECU power connector
- Wire broken inside its insulation near a bend or clamp
- The ECU supply circuit burnt open or its internal lead broken
Checks
- 1Check that the ecu power connector at the ECU power connector is fully seated and its lock tab engaged.
- 2Measure the resistance of the ECU supply circuit with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the ecu power plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat B1005-00Key switch multiple
The controller reports multiple inputs at once on the key switch, for example two directions active together, which a healthy control cannot do, so the controller cannot read the key position, so the machine may not start or run.· OtherOtherCheck soonCauses
- Joystick or handle sensor failed
- Shorted wires between two signal lines
- Water in the connector
Checks
- 1Release the control and read each axis on the service screen to find which one reads active.
- 2Unplug the key switch connector and inspect the pins for water and bridging.
- 3Replace the the key switch contacts if two axes read active with the control at rest.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat W3275ACS interrupted unswitched power
The acs lost its supply briefly while the machine was running, so the switched feed to that controller drops out. It also appears after a software update or a jump start.· Part or controllerPart or controllerCheck soonCauses
- Battery terminal or main ground loose
- Supply fuse or connector intermittent
- Low battery during cranking
Checks
- 1Check battery terminals and the main ground strap for tight clean connections.
- 2Check the controller supply fuse and connector for heat marks.
- 3Clear the code and watch whether it returns after the next start.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Bobcat M6402Switched power relay error on
The controller sees the switched power relay switched on when it was commanded off, so the feed stays on after key off. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the switched power relay at the relay socket in the fuse panel with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the relay and its socket energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6403Switched power relay error off
The controller sees the switched power relay off when it was commanded on, so the switched feed to the controller or display drops out. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The relay and its socket failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the switched power relay circuit with the key on.
- 2Measure the resistance of the relay and its socket and look for an open or a short to its body.
- 3Command the function and measure voltage at the switched power relay plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M6505ECU power short to battery
ECU power short to battery: same fault as C100A-12 (the circuit reads tied to battery voltage), here on the ecu power.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the ecu power and look for voltage on its output wire with the key on.
- 2Test steps: see C100A-12.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M6506ECU power short to ground
ECU power short to ground: same fault as C100A-11 (the circuit reads pulled to ground), here on the ecu power.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The ECU supply circuit shorted to its housing
Checks
- 1Test the ecu power output wire to chassis ground with the plug off.
- 2Test steps: see C100A-11.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M6507ECU power open circuit
ECU power open circuit: same fault as C100A-13 (the circuit is open), here on the ecu power.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the ecu power connector is seated, then measure across the part for an open.
- 2Test steps: see C100A-13.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M7002Switched power output error on
The controller sees the switched power output switched on when it was commanded off, so the output stays powered with the key off. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the switched power output at the controller supply connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the supply circuit energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M7003Switched power output error off
The controller sees the switched power output off when it was commanded on, so the switched feed to that controller drops out. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The supply circuit failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the switched power output circuit with the key on.
- 2Measure the resistance of the supply circuit and look for an open or a short to its body.
- 3Command the function and measure voltage at the switched power output plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M7007Switched power output open circuit
The controller sees an open circuit on the switched power output, so no current can flow through it and the switched feed to that controller drops out. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the controller supply connector
- Wire broken inside its insulation near a bend or clamp
- The supply circuit burnt open or its internal lead broken
Checks
- 1Check that the switched power output connector at the controller supply connector is fully seated and its lock tab engaged.
- 2Measure the resistance of the supply circuit with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the switched power output plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M7028Switched power output failure
The controller reports a failure on the switched power output without saying whether it is open, shorted or stuck, so the switched feed to that controller drops out. It is a general output fault rather than one failure mode.· OtherOtherCheck soonCauses
- Driver damaged by an earlier short or overload
- Corroded or loose connector at the controller supply connector
- Intermittent break in the harness
- Controller output stage failed
Checks
- 1Read the other active codes for the switched power output; a short or open code beside this one narrows the cause.
- 2Reseat the connector at the controller supply connector and clear the code to see whether it returns.
- 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7588Drive/drive+ switched power stuck on
The controller sees the drive drive switched power switched on when it was commanded off, so the output stays powered with the key off. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the drive drive switched power at the controller supply connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the supply circuit energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7589Drive switched power error off
The controller sees the switched power off when it was commanded on, so the switched feed to that controller drops out. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The supply circuit failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the switched power circuit with the key on.
- 2Measure the resistance of the supply circuit and look for an open or a short to its body.
- 3Command the function and measure voltage at the switched power plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M7748Key switch multiple
Key switch multiple: same fault as B1005-00 (two inputs read active at the same time), here on the key switch.· OtherOtherCheck soonCauses
- Joystick or handle sensor failed
- Shorted wires between two signal lines
Checks
- 1Release the control and read each axis on the service screen.
- 2Test steps: see B1005-00.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Check the fuses for the ECU and switched power feeds, including the fuse holder terminals for heat discoloration.
- 2Turn the key through each position and watch the service screen key-switch state; a missing run or start input points to the switch.
- 3Swap the ECU power relay with an identical one and see whether the symptom moves.
- 4Measure voltage at the controller power pins in the key-on state and again while cranking.
- 5Check for a harness short on the switched output by unplugging its loads one at a time.
Causes
- Blown fuse or loose fuse holder in the switched feed
- Key switch contacts worn or its connector loose
- ECU power relay stuck or its socket burnt
- Switched power output shorted by a damaged harness
Most common here: shorted low (6 of 19)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: The machine will not wake up, stalls when the key is turned, or several functions drop out together.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.