EF Logo

Bobcat · Controller

Bobcat Auxiliary, attachment and workgroup controllers fault codes

Secondary controllers manage the attachment control device, the auxiliary hydraulics, the rear auxiliary valve and the workgroup (lift and tilt) functions. A code reports a controller that has lost communication, needs calibration, or has a status message.

FaultCheck36-48Bobcat · Auxiliary, attachment and workgroup controllers
Code shows hereFAULT36-48

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes 36-48 to A7901 are all about the auxiliary, attachment and workgroup controllers. The most common failure type is part or controller (12 of 27); none needs an immediate stop. Start with this check: check which controller is named and measure its supply and ground at the connector.

How urgent are they?

None of the 27 codes here means stop now; 20 can wait until the shift ends, but find the cause before the next one; 7 are information only.

  • Check soon20
  • Info7

What should I check first?

Check which controller is named and measure its supply and ground at the connector.

Shared checks

27 of 27

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat 36-48ACD multiple controllers present

    The controller reports multiple inputs at once on the controllers present, for example two directions active together, which a healthy control cannot do, so the function is limited.· Other
    Check soon

    Causes

    • Joystick or handle sensor failed
    • Shorted wires between two signal lines
    • Water in the connector

    Checks

    1. 1Release the control and read each axis on the service screen to find which one reads active.
    2. 2Unplug the controllers present connector and inspect the pins for water and bridging.
    3. 3Replace the the controller supply if two axes read active with the control at rest.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat A0618Wheel speed out of range

    The controller reads the wheel speed signal outside its allowed range without saying whether it is high or low, so the function is limited.· Other
    Check soon

    Causes

    • Sensor drifting or failed
    • Poor connection at the controller connector
    • Wiring damage
    • Real condition beyond the sensor range

    Checks

    1. 1Compare the wheel speed value on the service screen with the real condition before replacing anything.
    2. 2Reseat the connector at the controller connector and check it for corrosion.
    3. 3Check the supply and ground at the sensor plug.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U1055-00Aux controller interrupted power failure

    The aux controller failure lost its supply briefly while the machine was running, so the auxiliary hydraulics are limited or lost.· Part or controller
    Check soon

    Causes

    • Battery terminal or main ground loose
    • Supply fuse or connector intermittent
    • Low battery during cranking

    Checks

    1. 1Check battery terminals and the main ground strap for tight clean connections.
    2. 2Check the controller supply fuse and connector for heat marks.
    3. 3Clear the code and watch whether it returns after the next start.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat U1056-00Rear auxiliary controller interrupted power failure

    The rear auxiliary controller failure lost its supply briefly while the machine was running, so the rear auxiliary function is lost.· Part or controller
    Check soon

    Causes

    • Battery terminal or main ground loose
    • Supply fuse or connector intermittent
    • Low battery during cranking

    Checks

    1. 1Check battery terminals and the main ground strap for tight clean connections.
    2. 2Check the controller supply fuse and connector for heat marks.
    3. 3Clear the code and watch whether it returns after the next start.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat U1060-46Workgroup calibration failed

    The workgroup calibration did not finish correctly, so the controller keeps the old or default values and lift and tilt functions are limited until the workgroup controller is calibrated.· Part or controller
    Check soon

    Causes

    • Hydraulic oil too cold or too hot for the procedure
    • Sensor or valve fault stopping the sequence
    • Calibration steps interrupted or done out of order

    Checks

    1. 1Warm the machine and repeat the workgroup calibration exactly as the service procedure describes.
    2. 2Clear other active codes before calibrating.
    3. 3Check the sensors and valves the procedure moves for sticking.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat U1060-87Workgroup calibration required

    The workgroup needs a calibration before it can run normally, so lift and tilt functions are limited until the workgroup controller is calibrated.· Lost message
    Check soon

    Causes

    • Controller or sensor replaced
    • Calibration lost after a reset or reprogramming

    Checks

    1. 1Run the workgroup calibration from the service menu.
    2. 2Check the machine is warm and on level ground as the procedure requires.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat U1061-00Workgroup calibration passed

    This is a status message, not a fault: the workgroup calibration passed.· Part or controller
    Info

    Causes

    • Calibration finished with results inside limits
    • Calibration was run after a part change

    Checks

    1. 1Clear the message and restart the machine.
    2. 2Test the function the calibration covers.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat U1084-00Workgroup in calibration mode

    This is a status message: the workgroup in is in calibration mode, so lift and tilt functions are limited until the workgroup controller is calibrated until the calibration is finished or cancelled.· Part or controller
    Info

    Causes

    • Calibration was started from the service menu
    • Calibration left unfinished

    Checks

    1. 1Finish the calibration or cancel it from the service menu.
    2. 2Restart the machine to leave calibration mode.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat U1097-08Aux controller bus signal / message failure

    The controller stopped receiving valid messages from the aux controller bus signal, so the auxiliary hydraulics are limited or lost.· Other
    Check soon

    Causes

    • Data wire chafed or loose
    • Supply to the unit interrupted
    • Unit failed or software mismatch

    Checks

    1. 1Check supply and ground at the aux controller bus signal connector.
    2. 2Check the message wiring for chafing and bent pins.
    3. 3Update the software through the dealer if a mismatch is suspected.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U1097-51Aux controller not programmed

    The aux controller has no valid program loaded, so the controller will not run its functions and the auxiliary hydraulics are limited or lost.· Other
    Check soon

    Causes

    • New or replaced controller never programmed
    • Software update interrupted
    • Memory corrupted

    Checks

    1. 1Program the aux controller with the dealer service tool and the correct software for the machine model.
    2. 2Check that supply stayed steady during the last update.
    3. 3After programming, calibrate and clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U1098-08Rear auxiliary controller communication error

    The controller reports a failure on the rear auxiliary controller communication without saying whether it is open, shorted or stuck, so the rear auxiliary function is lost.· Lost message
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the rear auxiliary controller connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the rear auxiliary controller communication; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the rear auxiliary controller connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat U1098-51Rear auxiliary controller not programmed

    The rear auxiliary controller has no valid program loaded, so the controller will not run its functions and the rear auxiliary function is lost.· Other
    Check soon

    Causes

    • New or replaced controller never programmed
    • Software update interrupted
    • Memory corrupted

    Checks

    1. 1Program the rear auxiliary controller with the dealer service tool and the correct software for the machine model.
    2. 2Check that supply stayed steady during the last update.
    3. 3After programming, calibrate and clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U1098-57Rear auxiliary controller software version error

    The controller reports a failure on the rear auxiliary controller software version without saying whether it is open, shorted or stuck, so the rear auxiliary function is lost.· Part or controller
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the rear auxiliary controller connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the rear auxiliary controller software version; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the rear auxiliary controller connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat M3204Workgroup controller no communication

    The controller has lost communication with the workgroup controller, so lift and tilt functions are limited until the workgroup controller is calibrated.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted
    • Unit failed or not programmed
    • Connector corroded at the workgroup controller connector

    Checks

    1. 1Measure supply and ground at the workgroup controller connector with the key on.
    2. 2Check the data wires for continuity and shorts, flexing the harness at the workgroup controller connector.
    3. 3Reseat the connector and clear the code to see whether communication returns.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat W3295Workgroup calibration passed

    Workgroup calibration passed: same fault as U1061-00 (the calibration passed), here on the workgroup.· Part or controller
    Info

    Causes

    • Calibration finished with results inside limits
    • Calibration was run after a part change

    Checks

    1. 1Clear the workgroup message and test the function.
    2. 2Test steps: see U1061-00.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat W3296Workgroup calibration failed

    Workgroup calibration failed: same fault as U1060-46 (the calibration failed), here on the workgroup.· Part or controller
    Check soon

    Causes

    • Hydraulic oil too cold or too hot for the procedure
    • Sensor or valve fault stopping the sequence

    Checks

    1. 1Warm the machine and repeat the workgroup calibration.
    2. 2Test steps: see U1060-46.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat W3298Workgroup in calibration mode

    Workgroup in calibration mode: same fault as U1084-00 (the controller is in calibration mode), here on the workgroup in.· Part or controller
    Info

    Causes

    • Calibration was started from the service menu
    • Calibration left unfinished

    Checks

    1. 1Finish or cancel the workgroup in calibration and restart.
    2. 2Test steps: see U1084-00.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat W3299Workgroup calibration required

    Workgroup calibration required: same fault as U1060-87 (a calibration is needed), here on the workgroup.· Part or controller
    Check soon

    Causes

    • Controller or sensor replaced
    • Calibration lost after a reset or reprogramming

    Checks

    1. 1Run the workgroup calibration from the service menu.
    2. 2Test steps: see U1060-87.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat A3623ACD not programmed

    The acd has no valid program loaded, so the controller will not run its functions and attachment control device functions are lost.· Other
    Check soon

    Causes

    • New or replaced controller never programmed
    • Software update interrupted
    • Memory corrupted

    Checks

    1. 1Program the acd with the dealer service tool and the correct software for the machine model.
    2. 2Check that supply stayed steady during the last update.
    3. 3After programming, calibrate and clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat H3648ACD multiple

    The controller reports multiple inputs at once on the acd, for example two directions active together, which a healthy control cannot do, so attachment control device functions are lost.· Other
    Check soon

    Causes

    • Joystick or handle sensor failed
    • Shorted wires between two signal lines
    • Water in the connector

    Checks

    1. 1Release the control and read each axis on the service screen to find which one reads active.
    2. 2Unplug the acd connector and inspect the pins for water and bridging.
    3. 3Replace the the controller supply if two axes read active with the control at rest.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M4404Auxiliary no communication

    The controller has lost communication with the auxiliary, so the auxiliary hydraulics are limited or lost.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted
    • Unit failed or not programmed
    • Connector corroded at the auxiliary controller connector

    Checks

    1. 1Measure supply and ground at the auxiliary connector with the key on.
    2. 2Check the data wires for continuity and shorts, flexing the harness at the auxiliary controller connector.
    3. 3Reseat the connector and clear the code to see whether communication returns.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat H4423Auxiliary not programmed

    The auxiliary has no valid program loaded, so the controller will not run its functions and the auxiliary hydraulics are limited or lost.· Other
    Check soon

    Causes

    • New or replaced controller never programmed
    • Software update interrupted
    • Memory corrupted

    Checks

    1. 1Program the auxiliary with the dealer service tool and the correct software for the machine model.
    2. 2Check that supply stayed steady during the last update.
    3. 3After programming, calibrate and clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M4472Secondary controller software incompatible

    The software in the secondary controller does not match the rest of the machine, so the auxiliary hydraulics are limited or lost.· Part or controller
    Check soon

    Causes

    • Controller replaced with a different software version
    • Update applied to one controller only
    • Wrong software file loaded

    Checks

    1. 1Read the software versions of each controller on the service screen.
    2. 2Update the secondary controller to the version that matches the machine through the dealer service tool.
    3. 3Clear the code and restart to confirm the versions agree.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat M4473Secondary controller software outdated

    The secondary controller is running older software than the machine now requires, so the auxiliary hydraulics are limited or lost until it is updated.· Part or controller
    Check soon

    Causes

    • Another controller was updated and this one was not
    • Old unit fitted as a replacement

    Checks

    1. 1Read the secondary controller software version on the service screen.
    2. 2Update it through the dealer service tool.
    3. 3Restart and confirm the code is gone.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat H4497Secondary controller programmed

    This is a status message, not a fault: the secondary was programmed successfully.· Other
    Info

    Causes

    • Programming completed normally
    • Controller was replaced or reflashed beforehand

    Checks

    1. 1Restart the machine and clear the message.
    2. 2Run the calibration the controller asks for next.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat A7701Key switch active

    This is a status message: the controller sees the key switch active on the attachment or auxiliary controller, which is the normal state with the key on.· Other
    Info

    Causes

    • Key is in the run position
    • Key switch input wired to the attachment controller

    Checks

    1. 1Compare the message with the real key position; it should only show with the key on.
    2. 2If it shows with the key off, check the key switch wiring for a short.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat A7901E-stop active

    The emergency stop input is active on the controller, so the machine functions it controls are disabled until the stop is released.· Other
    Info

    Causes

    • E-stop button pressed
    • E-stop circuit open or shorted
    • Stop switch connector loose

    Checks

    1. 1Release and reset the emergency stop button.
    2. 2Check the E-stop wiring and connector for an open circuit.
    3. 3Clear the code after the stop is reset and confirm it does not return.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Check which controller is named and measure its supply and ground at the connector.
  2. 2Check CAN wiring continuity back to the main controller.
  3. 3Run the workgroup or attachment calibration after replacing any valve, sensor or controller.
  4. 4Disconnect the attachment and check whether the status code clears.
  5. 5Reflash software only through the dealer tool.

Causes

  • Controller power or ground connection lost
  • CAN link between controllers interrupted
  • Workgroup calibration lost after a valve or sensor change
  • Attachment controller fault from an incompatible attachment

Most common here: part or controller (12 of 27)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: Attachment, auxiliary or workgroup functions are disabled or limited and a calibration or controller message shows.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder