EF Logo

JCB · Engine ECU (Dieselmax / Ecomax) - fuel system

JCB Lift pump, fuel contamination and fuel level sensors fault codes

The lift pump pulls diesel from the tank and feeds the high-pressure pump. The ECU switches it through a relay, so these codes cover the pump circuit and the relay output.

More about these parts

The fuel filter clogging sensor watches the pressure drop across the filter, and the water-in-fuel sensor in the filter bowl detects collected water. Both warn the operator before dirty or wet fuel damages the injection equipment. The fuel level sender in the tank is a float and variable resistor read by the machine controller. It drives the fuel gauge and the low and empty fuel alarms.

FaultInfoC101DJCB · Lift pump, fuel contamination and fuel level sensors
Code shows hereFAULTC101D

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes C101D to P2269 are all about the lift pump, fuel contamination and fuel level sensors. The most common failure type is open circuit (3 of 17); none needs an immediate stop. Start with this check: listen for the lift pump priming for a few seconds when the key goes on.

How urgent are they?

None of the 17 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon16
  • Info1

What should I check first?

Listen for the lift pump priming for a few seconds when the key goes on

Shared checks

17 of 17

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB C101DFuel level low alarm

    The fuel level has fallen to the low alarm point.· Other
    Info

    Causes

    • Fuel actually running low
    • Fuel level sender float stuck or reading low
    • Wire to the fuel sender damaged

    Checks

    1. 1Look at the fuel in the tank and refuel if low
    2. 2Compare the gauge reading with the real fuel level
    3. 3Check the sender wiring and plug for corrosion
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB C101EFuel level empty alarm

    The fuel level has fallen to empty.· Lost message
    Check soon

    Causes

    • Fuel tank actually empty
    • Fuel level sender reading empty in error
    • Open circuit in the sender wire

    Checks

    1. 1Refuel the machine, then check the gauge rises
    2. 2If the engine ran dry, bleed the fuel system before restarting
    3. 3Check the sender connector for corrosion and bent pins
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB C101FFuel level sensor short circuit

    Fuel level sensor short circuit.· Short circuit
    Check soon

    Causes

    • Fuel level sensor coil shorted internally, drawing too much current
    • Harness chafed through and touching the frame or a supply wire near the fuel level sensor
    • Water in the fuel level sensor connector

    Checks

    1. 1Unplug the fuel level sensor and measure its resistance, looking for a very low reading
    2. 2Check each wire for a short to ground and to battery with the plug removed
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB P0627Lift pump circuit open

    The ECU found the fuel lift pump drive circuit open, so the pump is not being powered.· Open circuit
    Check soon

    Causes

    • Open circuit in the lift pump feed or its relay drive
    • Failed lift pump motor, drawing no current
    • Blown lift pump fuse or a corroded relay socket

    Checks

    1. 1Listen for the lift pump priming for a few seconds when the key is turned on
    2. 2Check the lift pump fuse and relay, and swap the relay with a known good one
    3. 3Measure voltage at the lift pump connector with the key on
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB P0628Lift pump circuit short to ground

    Lift pump circuit short to ground.· Shorted low
    Check soon

    Causes

    • Wire for the lift pump circuit short to ground chafed and touching chassis or engine ground
    • Lift pump circuit short to ground coil or sensor shorted internally

    Checks

    1. 1Unplug the lift pump circuit short to ground and check each wire for a short to chassis ground
    2. 2Measure the resistance of the lift pump circuit short to ground and compare it with the manual value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P0629Lift pump circuit short to battery

    Lift pump circuit short to battery.· Shorted high
    Check soon

    Causes

    • Wire for the lift pump circuit short to battery touching a battery-fed wire in the harness
    • Water or damage inside the lift pump circuit short to battery connector bridging to supply

    Checks

    1. 1Unplug the lift pump circuit short to battery and check the signal wire for voltage with the key on, any battery voltage means a short to supply
    2. 2Inspect the harness for chafing where it crosses live wires near the lift pump circuit short to battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB P0656Fuel level sensor output circuit fault

    Fuel level sensor output circuit fault.· Other
    Check soon

    Causes

    • Fuel level sensor output circuit or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the fuel level sensor output circuit and look for a value that is stuck or implausible
    2. 2Check the fuel level sensor output circuit connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB C1020Fuel level sensor open circuit

    Fuel level sensor open circuit.· Open circuit
    Check soon

    Causes

    • Open wire or pushed-back pin between the controller and the fuel level sensor
    • Fuel level sensor coil, element or sensor internally open

    Checks

    1. 1Unplug the fuel level sensor and measure across its pins, an open reading means the part is faulty
    2. 2Check continuity of each wire from the fuel level sensor plug to the controller pin
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB P1293Fuel filter clogging sensor low voltage

    Fuel filter clogging sensor low voltage.· Shorted low
    Check soon

    Causes

    • Fuel filter clogging sensor signal pulled low by a short to ground or an open supply
    • Sensor or part failed giving a low reading

    Checks

    1. 1Read the fuel filter clogging sensor value on live data and compare it with the expected value
    2. 2Unplug the fuel filter clogging sensor and check the signal wire for a short to ground and the supply for 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P1294Fuel filter clogging sensor high voltage

    Fuel filter clogging sensor high voltage.· Shorted high
    Check soon

    Causes

    • Fuel filter clogging sensor signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the fuel filter clogging sensor value on live data and compare it with the expected value
    2. 2Unplug the fuel filter clogging sensor and check the signal wire for a short to 5 V or battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB B1303Fuel lift pump relay short circuit

    The fuel lift pump relay circuit is shorted, so the ECU switches the output off.· Short circuit
    Check soon

    Causes

    • Relay coil winding shorted
    • Relay control wire shorted to ground or supply
    • Water in the relay socket

    Checks

    1. 1Swap the lift pump relay with a known good one of the same type
    2. 2Check the relay socket for burning and moisture
    3. 3Check the control wire for a short to ground or supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB B1304Fuel lift pump relay open circuit

    The fuel lift pump relay circuit is open, so the ECU cannot drive the relay.· Open circuit
    Check soon

    Causes

    • Relay coil open
    • Relay control wire broken or pin backed out
    • Corroded relay socket

    Checks

    1. 1Swap the relay with a known good one and see if the pump runs
    2. 2Check the relay coil resistance for an open circuit
    3. 3Check the control wire for continuity back to the ECU
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB P2264Water in fuel sensor feedback signal ADC fault

    Water in fuel sensor feedback signal ADC fault.· Other
    Check soon

    Causes

    • Water in fuel sensor feedback signal ADC or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the water in fuel sensor feedback signal ADC and look for a value that is stuck or implausible
    2. 2Check the water in fuel sensor feedback signal ADC connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2265Water in fuel sensor plausibility fault

    Water in fuel sensor plausibility fault.· Erratic or implausible
    Check soon

    Causes

    • Water in fuel sensor plausibility drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the water in fuel sensor plausibility circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the water in fuel sensor plausibility value on live data with a known good value or a reference gauge
    2. 2Check the water in fuel sensor plausibility connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P2266Water in fuel sensor signal low

    Water in fuel sensor signal low.· Other
    Check soon

    Causes

    • Water in fuel sensor signal pulled low by a short to ground or an open supply
    • Sensor or part failed giving a low reading

    Checks

    1. 1Read the water in fuel sensor value on live data and compare it with the expected value
    2. 2Unplug the water in fuel sensor and check the signal wire for a short to ground and the supply for 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2267Water in fuel sensor signal high

    Water in fuel sensor signal high.· Other
    Check soon

    Causes

    • Water in fuel sensor signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the water in fuel sensor value on live data and compare it with the expected value
    2. 2Unplug the water in fuel sensor and check the signal wire for a short to 5 V or battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2269Water in fuel detected

    Water in fuel detected.· Other
    Check soon

    Causes

    • Water in fuel detected or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the water in fuel detected and look for a value that is stuck or implausible
    2. 2Check the water in fuel detected connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Listen for the lift pump priming for a few seconds when the key goes on
  2. 2Drain the water from the filter bowl and see whether the warning clears
  3. 3Compare the gauge reading with the real fuel level seen through the filler
  4. 4Check the pump fuse and relay, and swap the relay with a known good one
  5. 5Check the filter service history and replace the filter if due
  6. 6Measure the sender resistance at empty and full and check it moves smoothly
  7. 7Measure supply voltage at the pump connector while the pump is commanded on

Causes

  • Lift pump motor failed or drawing too much current
  • Water collected in the filter bowl
  • Fuel sender float stuck or resistor track worn
  • Lift pump relay or fuse faulty

Most common here: open circuit (3 of 17)

Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

When to stop

You'll notice: The engine may crank but not start, or lose power and stall under load because the high-pressure pump is not being fed.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.