EF Logo

J1939 · Aftertreatment - DPF

SPN 3242 FMI 4

DPF intake temperature sensor voltage low

What does SPN 3242 FMI 4 mean?

The DPF intake temperature sensor signal reads below its valid range, which the ECM sees as a short to ground or a lost supply. Urgency: check soon - the machine may derate or limit a function. Check first: watch the DPF intake temperature sensor live with the key on; a reading at its maximum on a cold start marks a grounded signal.

FaultCheckSPN 3242FMI 4J1939 engine ECU
FMI 4
Voltage below normal or shorted low

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Watch the DPF intake temperature sensor live with the key on; a reading at its maximum on a cold start marks a grounded signal

Then 4 more checks
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a J1939-capable scan tool to the 9-pin diagnostic port.

Checks

0 of 5 done

Causes

  • Signal wire rubbed bare and touching ground, so the ECM sees almost zero volts
  • Signal pulled to ground by a shorted DPF intake temperature sensor element or a squeezed harness
  • Lead caught under the canister band clamp and shorted to the shell
  • Soot-laden condensate pooled in the plug, bridging signal and return
1 more cause
  • Insulation burnt off where the lead crosses the regeneration heat zone

How it failed

You'll notice: The ECM loses the gas temperature entering the particulate filter, so it cannot manage a regeneration safely.

Shorted lowRead from FMI 4: voltage below normal or shorted low

The signal sits at or near zero volts - less than a working sensor can send.

ControllerPartSupplySignalGround
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good result
Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

When to stop

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Source

Cummins ISX15 2013-2018 fault codes list (Diesel Laptops)

This list shows SPN 3242 with FMI 4. The guidance on this page is general, not taken from it.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.