J1939 · Aftertreatment - SCR/DEF
SPN 3226 FMI 13
Outlet NOx sensor signal unavailable
What does SPN 3226 FMI 13 mean?
The ECM is not getting a usable signal from the outlet NOx sensor. SCR checks cannot be run, so a derate can follow. Urgency: check soon - the machine may derate or limit a function. Check first: check supply and ground at the NOx module with the key on and the engine running.
- SPN 3226
- Aftertreatment 1 outlet NOx
- FMI 13
- Out of calibration
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Check supply and ground at the NOx module with the key on and the engine running
Then 4 more checksWhere to read it
Connect a J1939-capable scan tool to the 9-pin diagnostic port.
Checks
0 of 5 done
Causes
- CAN wiring to the outlet sensor module open, shorted or corroded
- Outlet NOx sensor failed internally, so the module reports it unavailable
- No power to the NOx module because of a blown fuse or a lost ground
- Module plug loose or full of moisture
How it failed
You'll notice: The ECM is not getting a usable signal from the outlet NOx sensor, so SCR checks cannot run.
Part or controllerRead from FMI 13: out of calibration
The controller reports a part, module or its software as faulty or not responding.
- Meter test
- Check power and ground at the module connector with the key on, then its fuses.
- Good result
- Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
When to stop
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Other SPN 3226 codes
Source
Detroit Diesel DD15 2017-2020 fault codes list (Diesel Laptops)
This list shows SPN 3226 with FMI 13. The guidance on this page is general, not taken from it.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.