J1939 · Electrical
SPN 168 FMI 18
Battery voltage low, moderately severe
What does SPN 168 FMI 18 mean?
System voltage at the ECM is low at the moderately severe level. Low voltage causes random codes, weak injector drive and hard starting. Urgency: check soon - the machine may derate or limit a function. Check first: measure battery voltage at rest, while cranking and with the engine running.
- FMI 18
- Below normal, moderately severe
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Measure battery voltage at rest, while cranking and with the engine running
Then 4 more checksWhere to read it
Connect a J1939-capable scan tool to the 9-pin diagnostic port.
Checks
0 of 5 done
Causes
- Weak or discharged batteries that cannot hold the voltage
- Alternator not charging from a worn belt, brush or regulator
- Loose or corroded battery terminals
- High resistance in the main ground cable or ECM ground
How it failed
You'll notice: System voltage at the ECM is low at the moderately severe level, so injectors drive weakly and the engine can start hard or throw random codes.
Real conditionRead from FMI 18: below normal, moderately severe
The sensor reading is valid but outside the allowed range - the problem may be real.
- Meter test
- Check the real value with a separate gauge or thermometer before blaming the sensor.
- Good result
- If the gauge agrees with the display, fix the machine, not the sensor.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Other SPN 168 codes
Source
Cummins ISX15 2013-2018 fault codes list (Diesel Laptops)
This list shows SPN 168 with FMI 18. The guidance on this page is general, not taken from it.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.